ABB aquamaster Quick Reference Manual

Other manuals for aquamaster: Quick Reference Manual
Manual is about: Electronic Commercial Water Meter with Integral Logger

Summary of aquamaster

  • Page 1

    Electronic commercial water meter with integral logger aquamaster tm quick reference guide im/amg/qrg_4.

  • Page 2: Abb

    Abb en iso 9001:2000 cert. No. Q5907 the company we are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of abb, a world leader in process automation technol...

  • Page 3

    1 88888.888. 8 gal m 3 ab .8.8.8.80 f t m 3 / h m g d g a l / s m b a r p s i 0 - pictorial displays left battery warning sensor fault empty pipe mains failure right battery warning lower display time flow velocity pressure flow rate upper display date forward flow total reverse flow total net flow ...

  • Page 4

    2 programming setting up the pc – hyperterminal setup (example from windows nt – other versions of windows may vary) from the windows start menu select programs – accessories – communications – hyperterminal. At 'new connection' enter : aquamaster at 'connect using' choose : com1 or com2 (depending ...

  • Page 5

    3 security access 4.0 access language :english login (password?) :log in level 0 space login (password?)? Login (password?) :2 level logged in 4.0 access 5.0 flow settings 6.0 pressure settings etc. Tab setup space tab esc tab tab there are two levels of password control: level default menus passwor...

  • Page 6

    4 >217 217=42 >217=42 217=write access denied flow units : l/s flow units? L/s flow units? L/m flow units : l/m fsd(100% or urv) 200 l/m (repeat space function key until required units are displayed) tab space space comments >248=setup 248=2 logged in enter password >112 112=1 l/s read present flow ...

  • Page 7

    5 parameter changes go to menu this procedure is only available on v2.30 or above. To quickly navigate the aquamaster menu structure, assuming that the menu system has been activated (by pressing tab 3 or 4 times) and that a suitable login level has been obtained, go to a given menu by typing its nu...

  • Page 8

    6 n o i t a m r o f n i 0 . 1 9 9 1 r e t s a m a u q a r 0 0 2 d e t i m i l b b a r 1 0 2 e s u o h e n o t s r 2 0 2 a t 3 0 1 l g , k u , d n a l g n e r 3 0 2 1 6 6 6 2 8 3 5 4 1 ) 0 ( 4 4 + l e t r 4 0 2 m o c . B b a . B g @ w o lf r 3 6 1 r e n w o : 2 2 6 1 n o i t a c o l : 2 6 0 2 e g a s...

  • Page 9

    7 s s e c c a m e t s y s 0 . 4 1 6 1 e g a u g n a l : 4 8 4 2 ) d r o w s s a p ( n i g o l : 0 9 4 2 d r o w s s a p e g n a h c : 4 0 5 2 d r o w s s a p t n e r r u c : 4 1 5 2 d r o w s s a p w e n : 4 2 5 2 d r o w s s a p w e n m r if n o c : 4 t i x e : 0 s g n i t t e s w o l f 0 . 5 2 1 1...

  • Page 10

    8 l o r t n o c f f i r a t 0 . 0 1 2 4 e m i t t r a t s e l c y c y li a d : 4 3 4 e m i t d n e e l c y c y li a d : 4 4 4 y a d t r a t s e l c y c y l k e e w : 4 5 4 y a d d n e e l c y c y l k e e w : 4 6 4 e t a d t r a t s e l c y c y l r a e y : 4 7 4 e t a d d n e e l c y c y l r a e y : ...

  • Page 11

    9 menu layout gsm versions (v2.4x software) s e c i v r e s s m s 0 . 3 1 2 6 3 1 . O n e n o h p t r o p e r o t u a : 4 2 8 3 2 . O n e n o h p t r o p e r o t u a : 4 1 9 3 3 . O n e n o h p t r o p e r o t u a : 4 s t r o p e r o t u a t x e t 4 9 3 n o i t a n i t s e d : 4 1 6 3 e l u d e h c ...

  • Page 12

    10 d e n i f e d e l c y c y l k e e w e d o m a f f i r a t b f f i r a t 1 d n e k e e w g n i r u d e m i t y a d t h g i n d n a y a d + d n e k e e w t a e m i t t h g i n k e e w g n i r u d 2 k e e w g n i r u d e m i t y a d t h g i n d n a y a d + k e e w g n i r u d e m i t t h g i n d n e...

  • Page 13

    11 wireless communications – gsm versions only access via gsm commissioning test for signal strength this provides a means of carrying out a radio signal test for selecting the optimum location for the antenna. The system can be tested in its final commissioned location and state (e.G. Manhole cover...

  • Page 14

    12 …wireless communications status gsm module status gsm module status [>368] shows the current gsm radio module status as one of: 0 = not configured 1 = off 2 = off (sim not fitted) 3 = ready 4 = waiting pin 5 = waiting puk 6 = waiting antitheft pin 7 = waiting antitheft puk 8 = waiting pin2 9 = wa...

  • Page 15

    13 wireless communications… sim access control this section describes the steps to change the gsm module's sim pin and access lock status. Since sim access lock and sim pin are both held in the sim they can also be changed by inserting the sim into a mobile phone and following the steps to change it...

  • Page 16

    14 …wireless communications using aquamaster to change a sim's access lock status this requires that the pin has already been configured. Cycle though options via menu item sim access lock [>367]. Using the command line, this can be set to value 0 for 'lock disabled' or 1 for 'lock enabled'. [if the...

  • Page 17

    15 flow and pressure report schedules note. Log and totaliser reports can not be sent unless the unit has been supplied from the factory with the sms logging option enabled (parameter 406=1). The flow report schedule (>388) and pressure report schedule (>389) can be set to either of the following op...

  • Page 18

    16 …wireless communications alarm auto-reports this controls the sending of a report should any one or more of these events occur: • a sensor error • a coil error • a power supply error to the coil drive • a battery alarm if the alarm reporting (>402) has been enabled, then on any of the above error...

  • Page 19: Products & Customer Support

    Products & customer support products automation systems • for the following industries: – chemical & pharmaceutical – food & beverage – manufacturing – metals and minerals – oil, gas & petrochemical – pulp and paper drives and motors • ac and dc drives, ac and dc machines, ac motors to 1kv • drive s...

  • Page 20

    Im/amg/qrg issue 4 the company’s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in uk (08.05) © abb 2005 abb inc analytical instruments 9716 s. Virginia st., ste. E reno, nevada 89521 usa tel: +1 (0) 775 85...