Ver:1.0 │ │ 31/12/2015 abb-welcome pos : 2 /di na4 - anleit ung en o nline/i nhalt /kn x/d oorentr y/ 83220- ap- xxx/tit elbl att - 83220-ap- xxx - abb @ 19\ mod_1323249806476_15. Doc x @ 111084 @ @ 1 m22344-w basic 4.3" video hands-free indoor station === ende der list e f ür t ext mar ke cover ===.
Abb-welcome pos : 6 / busch-j aeger (neus trukt ur)/m odul-str ukt ur/o nline-dokumentation/Ü bers chrift en (--> für alle dokumente 1 safety pos : 7 / busch-j aeger (neus trukt ur)/m odul-str ukt ur/o nline-dokumentation/ sicherheit (--> für all e d okument e warning electric voltage! Risk of death...
Abb-welcome (eu-directive 2002/96/eg weee and 2002/95/eg rohs) (eu-reach ordinance and law for the implementation of the ordinance (eg) no.1907/2006).
Abb-welcome pos : 18 /dina4 - anl eitungen onli ne/ueberschrif ten/ 1. /bedi enung @ 18\ mod_1302613924165_15. Doc x @ 103365 @ 1 @ 1 4 operations pos : 19 /dina4 - anl eitungen onli ne/ueberschrif ten/ 2. /nor maler betrieb @ 18\ mod_1302768820965_15.Doc x @ 103540 @ 2 @ 1 4.1 standard operations p...
Abb-welcome no. Functions 1 4.3" color display 2 comunication button 2a when a call is coming, press this button to activate the communication within 30 seconds and press it again to end the call. 2b in standby mode, press this button to enter the communication menu. If the led flashes slowly, this ...
Abb-welcome pos : 26 /dina4 - anl eitungen onli ne/ueberschrif ten/ 2. /bedi enaktionen @ 20\ mod_1323262294281_15. Doc x @ 111911 @ 2 @ 1 4.2 control actions pos : 27 /dina4 - anl eitungen onli ne/ueberschrif ten/ 3. /sprec h- und videover bindung @ 20\ mod_1323262368700_15.Doc x @ 111927 @ 3 @ 1 4...
Abb-welcome pos : 30 /dina4 - anl eitungen onli ne/ueberschrif ten/ 3. /tuer oeff nen @ 20\ mod_1323263277453_15.Doc x @ 111935 @ 3 @ 1 4.2.2 display & volume settings during calling pos : 31 /dina4 - anl eitungen onli ne/i nhalt/ kn x/d oor entr y/83220-ap- xxx/t uer oef fnen - 83220- ap- xxx @ 20\...
Abb-welcome pos : 33 /dina4 - anl eitungen onli ne/ueberschrif ten/ 3. /st umm s chalt en @ 20\ mod_1323263607142_15. Doc x @ 111951 @ 3 @ 1 pos : 66 /busc h-j aeg er (neustr ukt ur)/modul- struktur /o nline-dokument ati on/steuermodul e - onli ne-d okument ation (--> f ür all e d okument e 4.2.3 co...
Abb-welcome 4.2.3.2 switch actuator fig. 4: switch actuator set the actuator list in the “system settings-switch actuator“ menu first. After chosing a list, press button √ to enable the lock or light which is connected with the switch actuator. Switch actuator actuator 1 (001).
Abb-welcome 4.3 settings 4.3.1 overview press button to enter the system settings menu. The following functions are available: no. Functions 1 switch actuator -set the actuator list in this menu 2 program button -set functions for programmable buttons 3 ringtone -set the ringtone for outdoor bells, ...
Abb-welcome 4.3.2 switch actuator settings fig. 5: switch actuator settings no. Functions 1 existing switch actuator list: press button √ to modify the settings. 2 add a new actuator list:totally, up to 10 switch actuator lists can be added. 3 enter to change target address with “+” or “-” button fr...
Abb-welcome 4.3.3 program button settings fig. 6: program button settings no. Functions 1 set functions for the program button, e.G. Releasing 2nd-lock, calling guard unit, enabling the switch actuator. *only the switch actuator list can be assigned to the program button. Button 1 release 2nd-lock p...
Abb-welcome 4.3.4 ringtone settings fig. 7: ringtone no. Functions 1 select the bell sound for the default outdoor station. 2 select the bell sound for other outdoor stations. 3 select the bell sound for the apartment door. 4 select the bell sound for others, e.G.A call from the guard unit 1 default...
Abb-welcome 4.3.5 volume settings fig. 8: volume settings no. Functions 1 set the volume of bell sound. 2 enable/disable the feedback tone which sounds when the touch button is pressed. 3 the ringtone can be set fixed or cycled. 1 ringtone volume touchbutton tone volume volume 3 2 √ repeated tone √ ...
Abb-welcome 4.3.6 date and time settings fig. 9: date and time settings no. Functions 1 set the date. 2 set the time. 3 enable/disable the summer time function. 1 date(yyyy-mm-dd) time date and time 2013 2 08 summer time √ : 00 - 01 - 01 3.
Abb-welcome 4.3.7 other settings fig. 10: other settings no. Functions 1 enable/disable the auto full screen function. 2 enable/disable the auto-snapshot function. 3 enable/disable the missed call function( flashes when there is a missed call). 1 auto full screen auto-snapshots other settings √ 2 mi...
Abb-welcome 4.3.8 history review fig. 11: history review no. Functions 1 up to 100 events can be recorded in the history menu. -if the snapshot function is enabled, an icon is diplayed.If no snapshot function, the icon is not displayed.. -date, time and type of the event are recorded together with t...
Abb-welcome 2 press this button to view details of this event. Two pictures are always made when a visitor rings the bell. 3 press this button to delete a record item.
Abb-welcome 4.3.9 language settings fig. 12: language settings english language.
Abb-welcome 4.3.10 information fig. 13: information of the indoor station (scanning the qr code to get the detailed instruction of the indoor station) flash version: v1.02_151210_us information mcu version: v1.02_151210_us m/s: master default outdoor: 1 indoor st. Add.: 001.
Abb-welcome 4.3.11 reseting factory default fig. 14: reseting factory default no. Functions 1 reset all settings: reset the device and restore all default configurations. The operation does not delete the programmed data and history, such as switch actuator lists. 2 clear all data: delete all progra...
Abb-welcome pos : 67 /dina4 - anl eitungen onli ne/ueberschrif ten/ 2. /rei nigung @ 19 \ mod_1310733980533_15. Doc x @ 107853 @ 2 @ 1 4.4 cleaning pos : 68 /dina4 - anl eitungen onli ne/i nhalt/ kn x/d oor entr y/rei nigung/rei nigung touc hscreenmonit or @ 19\ mod_1310734108978_15. Doc x @ 107862 ...
Abb-welcome pos : 70 /dina4 - anl eitungen onli ne/ueberschrif ten/ 2. /g eraet eei nst ellungen @ 18\ mod_1302768847744_15.Doc x @ 103548 @ 2 @ 1 4.5 adjusting the device pos : 71 /dina4 - anl eitungen onli ne/ueberschrif ten/ 3. /absc hlus s widerst and @ 19\ mod_1321958079906_15.Doc x @ 110083 @ ...
Abb-welcome pos : 76 /dina4 - anl eitungen onli ne/ueberschrif ten/ 1. /tec hnisc he d at en @ 18\ mod_1302615863001_15.Doc x @ 103416 @ 1 @ 1 5 technical data pos : 77 /dina4 - anl eitungen onli ne/i nhalt/ kn x/d oor entr y/83220-ap- xxx/t ec hnische d at en - 83220-ap- xxx @ 18\ mod_1303212854559...
Abb-welcome pos : 79 /busc h-j aeg er (neustr ukt ur)/modul- struktur /o nline-dokument ati on/Übersc hrift en (--> für alle d okument e 6 mounting / installation pos : 80 /busc h-j aeg er (neustr ukt ur)/modul- struktur /o nline-dokument ati on/sic herheit (--> für alle dokumente warning electric v...
Abb-welcome 6.2 general installation instructions • terminate all branches of the wiring system via a connected bus device (e.G., indoor station, outdoor station, system device). • do not install the system controller directly next to the bell transformer and other power supplies (to avoid interfere...
Abb-welcome pos : 84 /busc h-j aeg er (neustr ukt ur)/modul- struktur /o nline-dokument ati on/Übersc hrift en (--> für alle d okument e 6.3 mounting recommended installation height dismantling open the housing of the panel by pulling the clamp at the bottom of the device..
Abb-welcome installation dimension 1. The bottom of the device has screw holes for fastening on the wall according to the above dimension instructions. 2. In addition, the bottom of the device can be fixed to the existing flush -mounted box. The dimension of the compatible flush-mounted box is shown...
Abb-welcome settings set addresses of the preferred outdoor stations and the address of the indoor station on the jumper (see chapter " adjusting the device "). Three types of installation: a. Surface-mounted 1) mounted on the wall 1. Fix the bottom of the device to the wall. 2. Latch the upper part...
Abb-welcome b. Desktop-mounted mounted with desktop bracket 1. Fix the bottom of the device to the desktop bracket. 2. Latch the upper part of the device onto its bottom part : place the upper side of the device on the lock-in lugs and then press the bottom side onto the bottom part of the device un...
Abb-welcome pos : 95 /dina4 - anl eitungen onli ne/i nhalt/ kn x/d oor entr y/pr ojektier ung-mer kblatt/ proj ekti erpos: 97 / busch-j aeger (neus trukt ur)/m odul-str ukt ur/o nline-dokumentation/r üc ks eit en (--> für alle d okument e notice === ende der list e f ür t ext mar ke bac kc over === ...