ABB vital 1 Original Instructions Manual

Manual is about: safety module

Summary of vital 1

  • Page 1

    Abb jokab safety varlabergsvägen 11, se-434 39, sweden www.Abb.Com/jokabsafety original instructions vital 1 safety module.

  • Page 2

    2tlc172156m0201, rev. C 2 www.Abb.Com/jokabsafety 2016-07-04 read and understand this document please read and understand this document before using the products. Please consult your abb jokab safety representative if you have any questions or comments. Warranty abb jokab safety’s exclusive warranty...

  • Page 3: Table Of Contents

    2tlc172156m0201, rev. C 3 www.Abb.Com/jokabsafety 2016-07-04 table of contents 1 introduction ..................................................................................................................................... 4 scope ...................................................................

  • Page 4: Introduction

    2tlc172156m0201, rev. C 4 www.Abb.Com/jokabsafety 2016-07-04 1 introduction scope the purpose of these instructions is to describe the safety module vital 1 and to provide the necessary information required for installation and operation. Audience this document is intended for authorized installatio...

  • Page 5: Overview

    2tlc172156m0201, rev. C 5 www.Abb.Com/jokabsafety 2016-07-04 2 overview general description vital 1 is a safety module that generates and monitors a dynamic safety signal, which makes it possible to achieve a redundant safety system that complies with pl e, category 4 using only a single dynamic saf...

  • Page 6

    2tlc172156m0201, rev. C 6 www.Abb.Com/jokabsafety 2016-07-04 function description the safety is based on a dynamic safety circuit, using a single dynamic safety signal that is both generated and monitored within vital 1. The function is described in three steps: 1. The dynamic safety signal is gener...

  • Page 7: Connections

    2tlc172156m0201, rev. C 7 www.Abb.Com/jokabsafety 2016-07-04 3 connections vital 1 electrical connections nb: shielded cable is recommended between this unit and the rest of the safety circuit. Nb: a switch to determine the functionality of the information output is located on the inside of the hous...

  • Page 8

    2tlc172156m0201, rev. C 8 www.Abb.Com/jokabsafety 2016-07-04 reset connections it is possible to choose manually supervised or automatic reset on vital 1. Warning! When manually supervised reset is used, the reset button must be placed such that:  it is outside the hazardous area, and cannot be rea...

  • Page 9

    2tlc172156m0201, rev. C 9 www.Abb.Com/jokabsafety 2016-07-04 warning! All power to the device must be disconnected before the connection blocks may be removed. Connection of s1 s1 must be connected to b1 when an even amount of sensors are connected to the vital 1 dynamic safety circuit (i.E. The num...

  • Page 10

    2tlc172156m0201, rev. C 10 www.Abb.Com/jokabsafety 2016-07-04 connection example: vital 1 connected to different safety devices nb: if the safety light beam spot 10/35 is connected to vital 1, the information output switch must be in position 2. See section output connections for further details. Ca...

  • Page 11

    2tlc172156m0201, rev. C 11 www.Abb.Com/jokabsafety 2016-07-04 number of edens that can be used with vital 1 the following table shows the number of edens that can be connected to vital 1 with the maximum voltage variation. The values have been established in a laboratory environment. The actual poss...

  • Page 12

    2tlc172156m0201, rev. C 12 www.Abb.Com/jokabsafety 2016-07-04 number of tina units that can be used with vital 1 the following table shows the numbers of tina 3a, tina 6a, tina 7a, smile tina and inca tina that can be connected to vital 1 with the max voltage variation. The values have been establis...

  • Page 13

    2tlc172156m0201, rev. C 13 www.Abb.Com/jokabsafety 2016-07-04 example connections of units and cable lengths to vital 1 three connection alternatives to comply with pl e according to en iso 13849-1, the connection of sensor/adaptor units in the vital safety circuit must be made as per the following ...

  • Page 14

    2tlc172156m0201, rev. C 14 www.Abb.Com/jokabsafety 2016-07-04 cable lengths and number of sensor/adaptor units for the three connection examples as a guideline value when determining the number of sensor/adaptor units that can be connected to a vital 1 unit, one spot t/r is equivalent to five eden o...

  • Page 15

    2tlc172156m0201, rev. C 15 www.Abb.Com/jokabsafety 2016-07-04 4 installation and maintenance installation precautions first mount the unit to a 35 mm din rail, then install all cables to the terminals of the connection blocks (use max. Tightening torque 1 nm). Nb: do not forget the s1 terminal if an...

  • Page 16: Operation

    2tlc172156m0201, rev. C 16 www.Abb.Com/jokabsafety 2016-07-04 5 operation led indication led indication description on: on supply voltage ok flash supply voltage below 18 vdc or short circuit off no supply voltage t: on dynamic signal output – ok off no dynamic signal output r: on dynamic signal inp...

  • Page 17: Technical Data

    2tlc172156m0201, rev. C 17 www.Abb.Com/jokabsafety 2016-07-04 6 technical data manufacturer address abb jokab safety varlabergsvägen 11 se-434 39 kungsbacka sweden article number/ordering data vital 1, ver. H (from 2011): 2tla020052r1000 power supply operating voltage (to vital, a1-a2) 24 vdc +15%, ...

  • Page 18

    2tlc172156m0201, rev. C 18 www.Abb.Com/jokabsafety 2016-07-04 connector two connection blocks with 7 terminals each (detachable) max tightening torque: 1 nm max connection area: solid conductors: 1 x 4 mm 2 / 2 x 1.5 mm 2 / 12 awg conductor with socket contact: 1 x 2.5 mm 2 / 2 x 1 mm 2 connection o...

  • Page 19

    2tlc172156m0201, rev. C 19 www.Abb.Com/jokabsafety 2016-07-04 intended use this equipment is intended for (csa/ul requirement):  indoor use  altitude max 2000 m  maximum relative humidity 80% at max 31°c and decreasing linearly to 50% at 40°c.  pollution degree 2  installation category (overvol...

  • Page 20

    2tlc172156m0201, rev. C 20 www.Abb.Com/jokabsafety 2016-07-04 7 ec declaration of conformity abb jokab safety varlabergsvägen 11, se-434 39, sweden www.Abb.Com/jokabsafety.