Aber Hot Tub Manufacturing Pacific 2004 User Manual

Manual is about: Hot Tub

Summary of Pacific 2004

  • Page 1

    Please read this manual before proceeding with installation. 2004 owner’s manual aber hot tub manufacturing ltd. British columbia, canada.

  • Page 2

    Introduction congratulations on your purchase of a pacific hot tub! Pacific hot tubs are built to the highest standards and will provide you with many years of enjoyment, providing you follow the instructions set out in this manual. Please take the time to read all of the instructions before you ins...

  • Page 3

    Table of contents 5 general precautions 7 site selection 8 site preparation 8 delivery access 9 electrical connection 10 pacific hot tub features 13 starting your pacific hot tub 15 operating your pacific hot tub pht 2004 s controls (s-series) pht 1000 series controls (t-series) pht 2002 titanium se...

  • Page 4

    General safety precautions it is important that you read and understand the following warnings and precautions before using, or allowing someone else to use your new hot tub. Doing so will ensure that you get the most out of your investment. 1. Water temperature above 38°c (celsius) may be injurious...

  • Page 5

    15. Columbia, comet s and fun spa – cord connected spa (only) important safety instructions danger – risk of injury a) replace damaged cord immediately. B) do not bury cord. C) connect to a grounded, grounding type receptacle only. Warning – this product is provided with a ground-fault circuit inter...

  • Page 6

    Site selection y our pacific hot tub is totally self-contained and portable. You can place it just about anywhere you wish; on a patio, deck, or even directly on the ground. Regardless of your choice of location, the hot tub should always be placed on a firm, level, well-drained base. When consideri...

  • Page 7

    Site preparation y our pacific hot tub has been engineered for installation on any firm level surface. While a concrete slab is the best for long-term use, other solid foundations are acceptable. Other suggestions include pea gravel or crushed rock, railroad ties, or pre-cast stepping-stones. As a h...

  • Page 8

    Electrical connection t he electrical connections to the digital equipment pack must be wired in accordance with all applicable, local electrical codes, and a licensed electrician must perform all electrical work. The hot tub must be installed at least 1.5m (5ft) from all metal surfaces unless each ...

  • Page 9

    10 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l pacific hot tub features xxl jumbo storm soft massage jet the soft massage jet works to create a gentle, soothing motion to help relax and ease the muscles in the lower lumbar region. To increase the speed of the rotating massage jet, turn the ...

  • Page 10

    11 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l pacific hot tub features directional cluster jets the cluster jets are designed to give you a deep penetrating massage. The direction of the water-flow can be customized by adjusting the position of the jet nozzle. Cluster jet cluster jets are ...

  • Page 11

    12 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l pacific hot tub features hot tub pillows featured on select models. Custom molded pillows provide comfort in various seats. To remove for maintenance use both hands to pull towards you from inside hot tub. (do not pull upwards or downwards.) to...

  • Page 12

    Starting your pacific hot tub in above freezing temperature a fter your hot tub has been moved to the final installation site and wired correctly, follow these instructions for start-up.The same steps apply each time the hot tub is emptied and refilled: 1. Turn off all electrical power to the equipm...

  • Page 13

    Special instructions for start up of hot tubs equipped with the stealth system (laing) for european models only y our pacific hot tub is equipped with one of the most efficient heating systems in the industry. To simplify start up procedures and to protect your investment, a special purge line has b...

  • Page 14

    15 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l operating instructions pht 1000 and 2002 controls (t & lt models) start up power-up system and “pur” will appear for 30 seconds while system is in purge mode and then normal operation will resume. The temperature setting will assume the previou...

  • Page 15

    Factory programming pht 1000 and 2002 (t & lt models) mini max digital – r09/r59 factory programming procedure rev:0/5 power-up system and “pur” is displayed on topside panel for 30 seconds while in purge mode. Regular operation will then assume. Press heat and light key until “r--” appears. “r--” i...

  • Page 16

    Troubleshooting guide pht 1000 and 2002 (t & lt models) mini max digital spa pak rev:05 using ct250 printed circuit board no display at topside – check that connection to main board is clean and sound at j8. – test a new topside control. – check for 120v primary power going into the transformer and ...

  • Page 17

    Troubleshooting guide pht 1000 and 2002 (t & lt models) display flashes “flo” – this indicates a flow problem where the pressure switch is not closing – check that filters are clean – check that water level is optimal (2/3 up the filter) opening – check for a flow obstruction or closed valve – check...

  • Page 18

    Troubleshooting guide pht 1000 and 2002 (t & lt models) temperature readout is wrong – remove temperature sensor/thermister from the tub location and submerge it directly into the water. This will verify if the sensor has been installed where ambient air has affected it or if it is defective. – insu...

  • Page 19

    Troubleshooting guide pht 1000 and 2002 (t & lt models) filter cycle does not operate – adjust the temperature set point to be within 2°f of the actual water temperature. If the water temperature creeps 2°f higher than the set temperature, the system will shut off to allow the water to cool. When th...

  • Page 20

    Operating instructions pht 2004 s controls (s models) start up power-up system and “r.X.X.” message is displayed for a few seconds, with “x.X.” indicating the software revision of your system and than normal operation will resume (the display will blink until someone presses a key). It may be necces...

  • Page 21

    Jets one press pump key to turn pump on at low speed. Press a second time to turn pump to high speed (with a dual-speed pump). A third time turns pump off. A built-in timer automatically turns pump off after 20 minutes, unless it has been manually deactivated. The “pump” indicator lights up when pum...

  • Page 22

    Factory programming pht 2004 s controls (s models) 1.1 display units during normal operation, the display shows the spa water temperature in ˚f or ˚c (see low level programming to select the temperature unit). The screen resolution on the display is 1˚f and 0.5˚c. After a power-up, the display will ...

  • Page 23

    Low level programming it is possible to configure various systems operating parameters from the keypad. This is normally done at gecko factory or by the spa manufacturer, but may be done at anytime. The configuration will be kept into an eeprom memory. To program these system parameters, the light s...

  • Page 24

    Troubleshooting guide pht 2004 s (s models) gecko uspa pack owner troubleshooting the pump has started up for one minute on several occasions and “filter cycle” indicator is flashing. Not a bug but a feature! Our smart winter mode protects your spa from the cold by automatically turning the pump on ...

  • Page 25

    “oh” (overheat) error condition – check that the spa water temperature is over 112°f. The system should be shut down in this state and will re-start automatically when the water cools below 112°f. – this indicates that the heater body is over 112°f. The system should be shut down in this state and w...

  • Page 26

    Troubleshooting guide pht 2004 s (s models) temperature readout is wrong – remove temperature sensor/thermister from the tub location and submerge it directly into the water. This will verify if the sensor has been installed where ambient air has affected it or if it is defective. – insulate the thr...

  • Page 27

    Operating instructions pht 2004 lx controls (lxt models) start up power-up system and “95” message appears on blinking display, “95” indicating the temperature of water (in f) and than normal operation will resume (the display will blink until someone presses a key). It may be neccessary to bleed ex...

  • Page 28

    Use up or down arrow key to change setting (from 1 to 4). Press light key again to set temperature unit (f or c). When the desired setting is displayed, press light key to save all settings and exit. An irregularly flashing “filter cycle” indicator means that the system has stopped filtering after 3...

  • Page 29

    Winter mode. To activate or deactivate suspension mode, press and hold pump 1 key for 5 seconds. Suspension mode is activated for 40 minutes. The “off” message will be displayed. All keys are disabled except for the light key. If the water temperature reaches 112˚f, the display will flash and stop a...

  • Page 30

    Factory programming pht 2004 lx controls (lxt models) 1.1 ozone output 1.1.1 ozone without a circulation pump duration on during filter cycle 1.1.2 ozone with a circulation pump duration this output is tuned on with the circulation pump. 1.2 circulation pump functionality if the spas temperature is ...

  • Page 31

    System configuration 1.4 jumper configuration jumper number function position 1 (left) position 2 (right) jmp-1 current mode hc lc no restricion the heater is not allowed to be turned on if pump #1 is on at high speed or if pump #2 is activated. Jmp-2 circulation pump cp installed cp not installed (...

  • Page 32

    Troubleshooting guide pht 2004 lx controls (lxt models) gecko sspa pack no display at topside – check that connection to main board is clean and proper. – test a new topside control. – check for 120v primary power going into the transformer and for 12v secondary power out of the transformer before r...

  • Page 33

    Troubleshooting guide pht 2004 lx controls (lxt models) “flo” error condition – this indicates a flow problem where the pressure switch is not closing – check that filters are clean – check that water level is optimal (2/3 up the filter) opening – check for a flow obstruction or closed valve – check...

  • Page 34

    Troubleshooting guide pht 2004 lx (lxt models) temperature readout is wrong – remove temperature sensor/thermister from the tub location and submerge it directly into the water. This will verify if the sensor has been installed where ambient air has affected it or if it is defective. – insulate the ...

  • Page 35

    Operating instructions pht 2004 ulx controls (ulxt models) start up power-up system and “x.X.X.” message is displayed for a few seconds, with “x.X.X.” indicating the software revision of your system and than normal operation will resume (the display will blink until someone presses a key). It may be...

  • Page 36

    5. Press enter key to confirm the new setting. The spa side control will return to normal mode. To set the duration of the cycle: 1. Enter the programming mode by pressing program key. 2. Select the filter cycle duration parameter by pressing list key until “fidu” is displayed. 3. Press enter key to...

  • Page 37

    Turns pump 1 off. A built-in timer automatically turns pump 1 off after 20 minutes, unless it has been manually deactivated. The “pump 1” icon lights up when pump 1 is on at high speed. It flashes when pump 1 is on at low speed. Starting pump 2: press pump 2 to turn pump 2 on at low speed. Press a s...

  • Page 38

    Parameter summary cl time of day flon filter cycle start fidu filter cycle duration econ economy mode start ecdu economy mode duration tu temperature unit (°f or °c) loc keypad lockout if the water temperature reaches 112˚f, the display will flash and stop all accessories (pump, light and ozonator)....

  • Page 39

    Troubleshooting guide pht 2004 ulx controls (ulxt models) gecko mspa-pack owner troubleshooting pumps have started up for one minute on several occasions and “filter cycle” icon is flashing. Not a bug but a feature! Our smart winter mode protects your system from the cold by turning pumps on for one...

  • Page 40

    Troubleshooting guide pht 2004 ulx controls (ulxt models) gecko mspa-pack no display at topside – check that connection to main board is clean. – test a new topside control. – check for 120v primary power going into the transformer and for 12v secondary power out of the transformer before replacing ...

  • Page 41

    Troubleshooting guide pht 2004 ulx controls (ulxt models) no heat – check the topside control for “hl” error condition. This indicates that the system has overheated. Make sure the temperature has fallen to less than 112°f and press the heat (up/down key) to reset. – check for flashing led at topsid...

  • Page 42

    Troubleshooting guide pht 2004 ulx controls (ulxt models) filter cycle does not operate – adjust the temperature set point to be within 2°f of the actual water temperature. If the water temperature creeps 2°f higher than the set temperature, the system will shut off to allow the water to cool. When ...

  • Page 43

    Factory programming pht 2004 ulx controls (ulxt models) 1.1 economy switch functionality when economy mode is set, the pack regulates the water temperature 20°c below the actual set point. Press economy button and follow sequence. Sequence 1st press 2nd press display on off default off logo or arrow...

  • Page 44

    1.4 smart winter mode functionality turn pumps on when ambient temperature is below 68°f (20°c)* duration pumps activate for 1 minute (every 2 hours or less) for at least 24 hours. Logo or arrow filter arrow or logo blinks. Note: all pumps and blower outputs are activated for 1 minute at various tim...

  • Page 45

    Low level programming functionality hold econo key for 20 seconds, 1st parameter will appear (up/down keys modify values) duration press econo key to display next parameter, system will reset after last parameter. Display as table below, default values in bold. Parameter display value of x pump #1 p...

  • Page 46

    General troubleshooting guide pacific models symptom possible cause action no heat 1. Water level too low add water 2. Dirty filter clean filter 3. Pressure switch adjustments too high adjust pressure switch 4. Faulty pressure switch field service required replace) 5. Burnt out heating element field...

  • Page 47

    Hot tub maintenance thermal cover a vinyl cleaner should be used regularly on your thermal cover. This will help guard against the sun’s damaging ultra violet rays and help to prevent mildew stains. We recommend a periodic treatment of non- silicone spray for outdoor covers to help repel rainwater. ...

  • Page 48

    Pacific hot tubs cabinet removal instructions 49 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l step – 1 to remove any of the 4 corner panels on your pacific hot tub, first you must remove each of the side panels located adjacent to the corner. Step – 2 there are 3 screws along the bottom of e...

  • Page 49

    Hot tub maintenance monthly maintenance cleaning the filter: filtering is done by pumping water through the fine polyester mesh of the filter. As water flows through the filter, suspended particles become trapped on its surface. It is necessary to remove the filter and clean the cartridge surface, g...

  • Page 50

    Winterizing pacific hot tubs are designed for winter use. If you would like to shut down your hot tub for the winter, call your dealer. For a minimal charge they will winterize the equipment and plumbing to prevent damage to the internal parts of your hot tub. Severe damage, that is not covered by t...

  • Page 51

    Chemical safety • do not mix chemicals with each other before adding to hot tub. Add only one chemical at a time. • accurately measure and use exact quantities specified – never more than what is recommended. • never add concentrated chemicals directly into hot tub. Dilute with water in a large plas...

  • Page 52

    Chemicals and general supplies hot tub tabs stabilizing chlorinating tablets used to control bacteria and algae in hot tub water. Ph up raises the ph of hot tub water. Ph down lowers the ph of hot tub water. Stain and scale multi-purpose concentrate that eliminates and prevents staining and scale fo...

  • Page 53

    Regular maintenance daily maintenance • operate filter for at least 4 hours per day (on systems without a stealth system or tidal wave system). • test ph and adjust to between 7.2 and 7.6. • test chlorine or bromine level and adjust. • re-test again each day for one week if the hot tub has just been...

  • Page 54: Pht 1000 & Pht 2002

    55 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l pht 1000 & pht 2002.

  • Page 55: Pht 1000 & Pht 2002

    56 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l pht 1000 & pht 2002.

  • Page 56

    57 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l lxt models (equipped with aqua-stealth).

  • Page 57

    58 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l lxt models.

  • Page 58

    59 pa c i f i c h o t t u b s o w n e r ’ s m a n u a l ulxt model.