Acaia Pearl Operation Manual

Manual is about: Coffee Scale

Summary of Pearl

  • Page 1

    Using your pearl fw 2.0.008 identification the instructions in this operation manual apply to acaia coffee scale. You have purchased a quality precision weighing scale that requires handling with care. Make sure to read through this operation manual prior to using the scale. Acaia pearl operation ma...

  • Page 2

    Disclaimer notice calibrate your scale using calibration weight of the appropriate tolerance (class). A scale can be no more accurate than standard masses to which it has been compared. For more details, please read calibration mode section in the operation manual. Caution: 1. Do not place any hot o...

  • Page 3: Contents

    Contents 4 chapter 1: scale at a glance 4 introduction 4 specification 5 scale overview 6 accessories 6 buttons 7 led indicators 7 battery charge 8 chapter 2: getting started 8 preparation 9 installation 10 chapter 3: basics 10 basic operations 10 modes 10 mode 0 - weighing mode 11 mode 1 - espresso...

  • Page 4

    Chapter 1: scale at a glance introduction thank you for choosing one of our scales. The acaia coffee scale is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience. First of all, check the shipping carton to find the followings: " acaia coffee scale "...

  • Page 5

    Scale overview *note: for the best performance, place the weight in center of weighing platform. Chapter 1: scale at a glance 5 weighing pan power button led display micro-b usb port tare button scale front scale back.

  • Page 6

    Accessories buttons * please find chapter 3: basics for more details. Button function example turn on long press to turn on the scale. Turn off double-tap the power button to turn off the scale. Switch mode (default) while the scale is turned on, press and hold for 2 seconds to switch mode. Start/st...

  • Page 7

    Led indicators battery charge / charge error the led indicator on the upper left lights on in orange when the battery is charging and lights off when the battery is fully charged. The indicator starts flashing when the usb cable is not working. Timer reset the timer displays from 0 to 59 seconds in ...

  • Page 8

    Chapter 2: getting started preparation this scale is intended for indoor use. Select a work place that is stable, vibration-free and, if possible, a horizontal location for the weighing platform. Do not locate the scale near any equipment/instrument which contains magnets. Avoid places where room te...

  • Page 9

    Installation to use ac adapter instead of the built-in battery, plug the usb cable into the micro-b usb port located on the back panel of the scale. Long press v to turn on the scale. * it is highly recommended to calibrate the scale with calibration weight before using. Please make sure to use a he...

  • Page 10: Chapter 3: Basics

    Chapter 3: basics basic operations modes *to enable/disable modes please go to chapter 5: configuration on page 16. Mode 0 - weighing mode mode 1 - espresso mode mode 2 - timer mode mode 3 - auto start mode mode 4 - beverage mode mode 5 - auto tare mode mode 0 - weighing mode 1. There are two differ...

  • Page 11

    Mode 1 -espresso mode 1. The led timer on the left, weighing result on the right. 2. The timer displays from 0 to 59 seconds in cycle and will reset when reaching 60 seconds. When it resets, the mode indicator flashes 3. The readability decreases when the the weight is over 99.9. The led display sho...

  • Page 12

    Mode 3 - auto start mode place materials on scale. Tap power button to automatically tare. Begin pouring and timer will start with the pour. Timer stops when brewing equipment is removed. *to enable/disable auto start mode, please go to chapter 5: configuration on page 16. Action operation initiate ...

  • Page 13

    Mode 4 - beverage mode follow instructions on the display to place the carafe, filter, and coffee (tap tare in between steps). Timer will start with the pour. Lift dripper and filter off to stop timer. The flashing number is your beverage weight with all items subtracted. 1. As soon as weight is sta...

  • Page 14

    Mode 5 - auto tare mode (after version 2.0.008) displays weight only. Place item on and off scale and it will automatically tare. *to enable/disable auto tare mode, please go to chapter 5: configuration on page 16. Action operation tare weight short press t reset mode double tap t switch mode long p...

  • Page 15: Chapter 4: Calibration

    Chapter 4: calibration calibration mode 1. While the scale is in weighing mode and the weighing unit is in gram, press t button quickly multiple times until led display shows [ cal ] and then [ 500 ]. 2. Place a 500g calibration weight on scale and wait for the scale to execute calibration procedure...

  • Page 16: Chapter 5: Configuration

    Chapter 5: configuration enter settings 1. Press and hold v while turning on the scale. 2. Keep v pressed. When the led display shows [ n acaia ] and turns [ set ], long press t for another 2 seconds without releasing button. 3. Release both v and t when displays [ f.0000 ]. 4. Long press t to move ...

  • Page 17

    Auto sleep settings auto sleep settings can also be configured in the acaia app. 1. The number indicates the amount of time before the scale enters sleeping mode. For example, when 10 is selected, the scale enters sleeping mode after 10 minutes of idling. Auto zero settings 1. When auto zero setting...

  • Page 18

    Notice: the difference between zero operation and tare operation is that zero operation would simply ignore the weight and display as 0 while tare operation would deduct the weight from weighing result. However, zero operation does not increase the scale capacity. Weighing filter setting 1. The numb...

  • Page 19: Appendix

    Appendix error code error code description 100 code error 101 eeprom error 102 ad read error over load: the weight is over the maximum capacity. Under load: the weight is under the minimum capacity. 303 unable to make zero point, for the initial weight exceeds the limit (50% of capacity). 304 please...

  • Page 20

    Copyright the operation manual is protected by copyright. All rights reserved. No part of the operation manual may be reproduced, processed, duplicated or published in any form by photocopying, microfilming, reprinting or any other method, in particular electronic means, without the written agreemen...