Access Specialties International RI-130 Installation & user manual - page 3
RI-130 Reader Interface Installation & User's Guide
I
NTRODUCTION
The RI-130 (Reader Interface) provides access control functions for a single entry. It is
capable of storing up to 15,000 transactions while in a degraded mode state. The RI-130
is designed to interface with the Access Gold™ and ASI 2000 software and the IC-1600
(Intelligent Controller). Most card technologies using weigand data output are supported.
Degraded mode is also supported.
The RI-130 supports variable time delay "go" and alarm shunt time relays. There is also
one auxiliary user-defined output relay. There are 9 user-defined monitoring points
available in addition to the Door Open Detect (DOD), Request To Exit, and Tamper
inputs.
There are several options for housing the RI-130. It can be mounted to a bracket that
may be used in either a surface or flush mount enclosure and appropriate Conversion Kit.
Standard electrical enclosures are also available for new installations.
S
PECIFICATIONS
Card
Technology Barium Ferrite, Wiegand, IBC, Mag Stripe,
Proximity Readers, etc…*
Momentary
Door
Unlocking
Switch selectable 2 to 16 seconds **
Alarm
Shunting Switch selectable 6 to 48 seconds **
Degraded
Mode
Switch selectable system code
12 Monitored Input Points Door Open Detect, Request To Exit, Tamper & 9
user-definable points
3 Controlled Output Points
Go Relay, Shunt Relay, & 1 User-definable
Output Door Relay
Contact Rating
120 VAC or 28DC @ 3A
Power
Requirements 12 VAC @ 60Hz, 1A or 12 volts DC at 1 A
Operating
Temperature -40
°C to 75+°C
*Contact Access Specialties for additional supported technologies.