Acclaim Lighting AL Graze DC User Manual

Summary of AL Graze DC

  • Page 1

    Www.Acclaimlighting.Com al graze dc (cv and dmx) user guide.

  • Page 3: Contents

    1 www.Acclaimlighting.Com contents introduction .....................................................................2 welcome 2 safety 2 supplied items 3 optional extras 3 installation ........................................................................5 mount adjustment 5 removing and replacin...

  • Page 4: Introduction

    2 www.Acclaimlighting.Com introduction welcome welcome to the al graze dc range from acclaim lighting. These aluminum bodied wet location (ip66) fixtures are designed specifically to graze indoor and outdoor surfaces in close proximity. Available in 1’ and 4’ lengths these robust units can be connec...

  • Page 5

    3 www.Acclaimlighting.Com supplied items optional extras al graze dc 1’ or 4’ with two swivel mount brackets fitted plus two additional flat brackets (and grub screws) link cables cv dmx 1’ (30cm) [agelc1] [agdlc1] 5’ (1.5m) [agelc5] [agdlc5] 10’ (3m) [agelc10] [agdlc10] feed cables plus end cap cv ...

  • Page 6

    4 www.Acclaimlighting.Com power supplies (115-230vac, 47-63hz input) 24vdc 240w (powers 2 x 12’ runs) [aps-240-24] 24vdc 480w (powers 4 x 12’ runs) [aps-480-24] glare shields 1’ (30cm) [ags1] 4’ (122cm) [ags4] optional extras (continued) louver 1’ (30cm) [aglv1] 4’ (122cm) [aglv4] extender bar 12” (...

  • Page 7: Installation

    5 www.Acclaimlighting.Com installation when installing each al graze dc fixture, ensure that the surface is level and that nothing is protruding to damage the mounting bracket(s). Suitable mounting surfaces include steel, aluminum, concrete or wood structures. Each mount bracket has two slots measur...

  • Page 8

    6 www.Acclaimlighting.Com removing and replacing brackets two types of mount brackets are supplied with each al graze dc fixture and these are easily changed. Use a 1/16th (1.5mm) allen wrench to loosen the two grub screws on each bracket. Then slide the bracket to the center of the fixture where th...

  • Page 9

    7 www.Acclaimlighting.Com fitting a glare shield optional glare shields are available for both sizes of al graze dc fixture; these can be quickly fitted on either side of the emitter housing to help conceal the emitters from side view. To fit a glare shield 1 line up the ledge of the glare shield wi...

  • Page 10

    8 www.Acclaimlighting.Com fitting extender bars a common fixing method is to use optional extender bars. These are available in 12” and 24” lengths. Two extender bars are required for each al graze dc fixture. Note: when feeding cables through the extender bar check for any metal burrs that may have...

  • Page 11

    9 www.Acclaimlighting.Com power and control wiring al graze dc fixtures use chogori™ standard (22) series ip67 connectors for their inputs and outputs. The connector placements at each end of every fixture are such that abutted fixtures can be directly connected without need for extra link cables: •...

  • Page 12

    10 www.Acclaimlighting.Com extending fixture runs beyond 12 feet due to the limited current carrying capacity of the internal power buses, runs of al graze dc fixtures must not exceed 12’ (3.65m). Where longer lengths are required you can either arrange separate parallel runs of up to 12’ or use the...

  • Page 13

    11 www.Acclaimlighting.Com m-series 24vdc dimmable transformer (al graze dc cv models only) the m-series magnetic transformers allow led fixtures to be integrated into an existing dimmed-circuit lighting installation. Dimmed mains input +24vdc gnd to al graze dc cv these transformers can be connecte...

  • Page 14

    12 www.Acclaimlighting.Com maximum number of fixtures the maximum number of fixtures that can be connected in a single series run is 12 feet (3.65m), as follows: 12 feet (3.65m) of total fixture length runs can consist of mixtures of 1’ and 4’ fixtures, as required, providing the total length of fix...

  • Page 15

    13 www.Acclaimlighting.Com making a temporary control link (al graze dc dmx models only) each xmt-350 dmx/rdm tool is supplied with a 5-pin male xlr lead that can be used to make a temporary control input link with the al graze dc dmx feed-in cable. Use a 3-pin terminal block, wire nuts, conn blocks...

  • Page 16: Operation

    14 www.Acclaimlighting.Com operation addressing fixtures (al graze dc dmx models only) al graze dc dmx fixtures have no external controls and instead rely on rdm (remote device management) for all configuration via the dmx interface. This allows multiple devices to be configured either before or aft...

  • Page 17

    15 www.Acclaimlighting.Com testing emitter output (al graze dc dmx models only) after you have addressed each al graze dc dmx fixture we recommend that you also test each one prior to installation. This can be achieved with your rdm (remote device management) tool. Various third party dmx/rdm tools ...

  • Page 18: Further Information

    16 www.Acclaimlighting.Com further information troubleshooting luminaire doesn’t turn on • check that power is correctly applied to the fixture and that there is no damage to the power input cord. • (dmx models) use an rdm tool (such as the swisson xmt-350) to check the settings and internal tempera...

  • Page 19

    17 www.Acclaimlighting.Com specifications color models cv: 2700k, 3000k, 3500k and 4000k white dmx: all above + rgb, rgbw, rgba or dynamic white (2200-5000k) beam angle options 15 o x 15 o , 10 o x 60 o , 30 o x 60 o or 60 o x 60 o illuminance (lm/ft 2 ) 419 (4000k 30 o x 60 o variant @ 100% - 1 foo...

  • Page 20

    18 www.Acclaimlighting.Com limited product warranty a. Acclaim lighting™ hereby warrants, to the original purchaser, acclaim lighting™ finished products to be free of manufacturing defects in material and workmanship for a standard period of: • fixtures: 5 years (1,825 days) from the date of purchas...

  • Page 22: Www.Acclaimlighting.Com

    Www.Acclaimlighting.Com.