  • Page 1

    Fast etherhub-12s &ino.

  • Page 2: Installation Manual

    Installation manual fast etherhub-12s smart fast ethernet hub with 12 100base-tx ports.

  • Page 3

    Copyright (c) 1997 by accton technology corporation. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of accton technology corporation. Accton makes no warranties with respect to this documentation and disclaims a...

  • Page 4: Package Contents

    Package contents i package contents carefully unpack the contents of the package and verify them against the checklist given below. Package checklist æ fast etherhub-12s (model no. Eh3012-tx) æ ac power cord (optional) æ four rubber foot pads æ installation manual æ warranty registration card please...

  • Page 5: Quick Installation

    Quick installation iii quick installation the fast etherhub-12s is a class ii repeater. It contains 12 100base-tx fast ethernet ports. The smart design built into the front display panel provides a friendly interface that simplifies installation and network troubleshooting. If you are already famili...

  • Page 6

    Fast etherhub-12s user’s guide iv quick installation first calculate the maximum length permitted between each pair of end nodes as described in chapter 2 under the section on precise cable length budgeting . 5. Verify network communications by ensuring that - • you have made all the necessary conne...

  • Page 7: About This Guide

    About this guide v about this guide this guide is designed for the experienced network installer. It describes how to install and operate accton’s fast etherhub-12s. After reading this manual, you should be able to use the front display panel and configure options to manage all your network connecti...

  • Page 8: Contents

    Contents contents vii chapter 1: product overview ................................................. 1-1 introduction to fast ethernet .....................................................................................1-1 accton’s fast etherhub-12s......................................................

  • Page 9

    Fast etherhub-12s user’s guide viii contents appendix a: troubleshooting ................................................ A-1 diagnosing hub indicators........................................................................................A-1 system diagnostics .........................................

  • Page 10

    Fast etherhub-12s user’s guide contents ix limited warranty .......................................................................................................E-4 customer remedies..............................................................................................E-4 return process ......

  • Page 11

    Product overview 1-1 chapter 1: product overview introduction to fast ethernet standard 10 mbps ethernet has served well for past generations of 286 and 386 machines performing simple file transfers. However, with the inevitable growth in corporate network size and the introduction of fully-function...

  • Page 12

    Fast etherhub-12s user’s guide 1-2 product overview basic features • transmits data at 100 mbps for demanding applications • conforms to the ieee 802.3u repeater specification for 100base-tx • provides 12 rj-45 100base-tx station ports (using mdi-x wiring) • port 12 can serve as an mdi-x station por...

  • Page 13

    Fast etherhub-12s user’s guide product overview 1-3 • with automatic partitioning and reconnection, any port is automatically isolated if excessive collisions occur on it. When the condition is corrected, the port is automatically reconnected. • with the jabber lock-up function, the hub automaticall...

  • Page 14

    Installing the system 2-1 chapter 2: installing the system this chapter provides information on installing the fast etherhub-12s, estab- lishing network connections, and configuring the system. You may install this hub on any level surface (e.G., a table or shelf) or in a standard eia equipment rack...

  • Page 15

    Fast etherhub-12s user’s guide 2-2 installing the system connecting the hub system this hub is a fast ethernet repeater for 100base-tx networks. The etherhub-12s has 12 rj-45 station ports, of which port 12 can serve as either a station port or a daisy-chain port (depending on the port’s switch sett...

  • Page 16

    Fast etherhub-12s user’s guide installing the system 2-3 making a connection via the mdi daisy-chain port 1. To make a direct connection to another compatible repeater or switch, use the 12mdi daisy-chain port. When connecting to this port, remember to set the port selection switch mdi . 2. Prepare ...

  • Page 17

    Fast etherhub-12s user’s guide 2-4 installing the system simplified cable length constraints the fast etherhub-12s is a class ii repeater. Ieee recommends that class ii hubs be limited to a cascade of two hubs. The simplest rule is that workstation connections be limited to 100 meters for twisted-pa...

  • Page 18

    Fast etherhub-12s user’s guide installing the system 2-5 connected hub when using twisted-pair cabling. However, when linking one or more fast ethernet repeaters together (i.E., in the same collision domain), the overall length of cable used between any two nodes should not exceed the limits outline...

  • Page 19

    Fast etherhub-12s user’s guide 2-6 installing the system verifying port status check each connection by viewing the port status indicators listed below. (for a more detailed description of these indicators, refer to chapter 4.) link indicates that the port has established a valid network connection....

  • Page 20

    Fast etherhub-12s user’s guide installing the system 2-7 • test the adapter for an attached workstation by trying it in another computer that has been successfully connected to the network. If you still can’t resolve the problem, please refer to troubleshooting in appendix a..

  • Page 21

    Configuring the network 3-1 chapter 3: configuring the network the fast etherhub-12s allows great flexibility in configuring your network. You can use it in a stand-alone or multiple hub configuration. Some of the common applications for this fast etherhub are described in this chapter. Stand-alone ...

  • Page 22

    Fast etherhub-12s user’s guide 3-2 configuring the network using the rj-45 daisy-chain port you can easily connect to another hub via the mdi daisy-chain port (port 12). When using simplied cable length constraints as described in chapter 2, the inter- hub cable length is 5 meters. Figure 3-2 shows ...

  • Page 23

    Fast etherhub-12s user’s guide configuring the network 3-3 precise guidelines for configuring multiple hubs a detailed formula for calculating maximum cable length was provided in the section on precise cable length budgeting in chapter 2. This formula stated that the maximum length of cabling that ...

  • Page 24

    Fast etherhub-12s user’s guide 3-4 configuring the network figure 3-3 cabling limits for multiple hub configuration notes: 1. The maximum length for each cable must be determined by calculations for the longest path (i.E., node-to-node connection) that passes through that segment. 2. To control the ...

  • Page 25

    Hardware reference 4-1 chapter 4: hardware reference before connecting any network device to this hub, please review chapter 2 for information on system installation and chapter 3 for a brief look at common network architectures. This chapter describes the hardware features of the fast etherhub-12s....

  • Page 26

    Fast etherhub-12s user’s guide 4-2 hardware reference the front panel array provides indicators that show the utilization of network bandwidth and indicate the status of port connections. It includes port status indicators and a statistical display for network traffic as shown below. Figure 4.2 indi...

  • Page 27

    Fast etherhub-12s user’s guide hardware reference 4-3 statistical display for system performance utilization - ( utilization% ) the statistical indicators show the percentage of valid data passing through all ports compared to overall network bandwidth (updated every 0.5 seconds). There are 5 leds r...

  • Page 28

    Fast etherhub-12s user’s guide 4-4 hardware reference note: if the hub displays a high collision rate, check to see if any of the connected devices are malfunctioning or if a loop has been formed in your network connections. Otherwise, you may need to reconfigure your network to balance the traffic ...

  • Page 29

    Fast etherhub-12s user’s guide hardware reference 4-5 troubleshooting : if the link led does not light up when a device is connected to its corre- sponding port, check that both the hub and connected device are powered on. Be sure the cable length for all devices connected to the hub are within the ...

  • Page 30

    Fast etherhub-12s user’s guide 4-6 hardware reference rear panel the rear panel on the hub includes a full-range power socket. Figure 4.3 rear panel power socket the power socket accepts ac power from 100 to 240v at 50 to 60hz. The unit is equipped with a universal full-range power source..

  • Page 31

    Troubleshooting a-1 appendix a: troubleshooting diagnosing hub indicators this fast etherhub can be easily monitored through its comprehensive panel indicators. These indicators assist the network manager in identifying problems the hub may encounter. This section describes common problems you may e...

  • Page 32

    Fast etherhub-12s user’s guide a-2 troubleshooting system diagnostics power and cooling problems if the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section. However...

  • Page 33

    Fast etherhub-12s user’s guide troubleshooting a-3 external adapters make sure the network interface hardware and software drivers for the attached devices are function properly. Check the adapter cards and associated drivers used in any attached workstation or server. Physical configuration if prob...

  • Page 34: Appendix B:

    Cable and port assignments b-1 appendix b: port and cable assignments rj-45 port figure b-1 rj-45 connector (on the hub side) pin mdi-x assignment (station port 1 ~ 12) mdi assignment (cascade port 12) 1 input receive data + output transmit data + 2 input receive data - output transmit data - 3 outp...

  • Page 35

    Product specifications c-1 appendix c: product specifications transmission technique baseband topology star or tree access method csma/cd, 100mbps standards conformance ieee 802.3u 100base-tx class ii repeater media supported unshielded or shielded twisted-pair cable (100 w category 5 stp/utp) inter...

  • Page 36: Appendix D:

    Regulatory standards compliance d-1 appendix d: regulatory standards compliance emi certification fcc class b certification accton technology corporation model numbers: eh3012-tx fcc id: hed3012ehlct-tx this device complies with part 15 of the fcc rules. Operation is subject to the following conditi...

  • Page 37

    Fast etherhub-12s user’s guide d-2 regulatory standards compliance warnings 1. Wear an anti-static wrist strap or take other suitable measures to prevent electrostatic discharge whenever handling this equipment. 2. When connecting this hub to a power outlet, connect the field ground lead on the tri-...

  • Page 38

    Fast etherhub-12s user’s guide regulatory standards compliance d-3 read the instructions for correct handling. European community immunity requirements this unit was tested and found to comply with the class b limits of en55022 (cispr 22) and the immunity requirements of en50082-1. Ce mark declarati...

  • Page 39

    Fast etherhub-12s user’s guide d-4 regulatory standards compliance safety compliance underwriters laboratories inc. Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following specification list. Operating voltage cord s...

  • Page 40

    Fast etherhub-12s user’s guide regulatory standards compliance d-5 sicherheitshinweise 1. Die steckdose muß sich in der nähe des gerätes befinden und leicht zugänglich sein. 2. Zum reinigen den stecker aus der steckdose ziehen. Beim reinigen keine flüssigreiniger oder sprays verwenden, sondern ein a...

  • Page 41: Appendix E:

    Product support services e-1 appendix e: product support services product registration fill in the owner registration card and mail it to accton technology corporation. Accton will keep your record and inform you of any new accton unit developments. Problem report if problems occur during unit opera...

  • Page 42

    Fast etherhub-12s user’s guide e-2 product support services after repair, accton will inform you of the date of delivery and the exact amount due. Please send the payment by t/t (telegram transfer), and accton will send you the fixed component after receiving payment. With or without warranty, if th...

  • Page 43

    Fast etherhub-12s user’s guide product support services e-3 technical support your dealer or installer is the person who understands your network and accton units. If neither is available to help you, accton technical support engineers are available by fax, mail or phone. • send your technical quest...

  • Page 44

    Fast etherhub-12s user’s guide e-4 product support services limited warranty accton warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for the lifetime of the product. For the warranty to apply, you must register your purch...

  • Page 45

    Fast etherhub-12s user’s guide product support services e-5 return process before you may return any accton product to accton, you must request an rma number by calling, faxing or writing accton’s service department at the address listed below. If you ship the product, you must assume the risk of da...

  • Page 46

    Fast etherhub-12s user’s guide e-6 product support services accton offices accton technology corporation international headquarters, no. 1 creation rd. Iii, science-based industrial park, hsinchu 300, taiwan, r.O.C. Hsinchu: phone: 886-3-5770-270, fax: 886-3-5770-267, 886-3-5775-541 bbs: 886-3-5770-...

  • Page 47: Glossary

    Glossary 1 glossary 100base-tx ieee’s specifications for 100 mbps ethernet using twisted-pair cable (100 w cat. 5 stp or utp ) . The maximum length of cable for a point-to-point connection is 100 meters. Collision a condition in which two packets transmitted over a medium interfere with each other. ...

  • Page 48

    Fast etherhub-12s user’s guide 2 glossary fast ethernet 100 mbps network communication system based on ethernet and the csma/cd access method. Ieee 802.3 standard standard for the physical and electrical connections in local area networks developed by the ieee. The ieee 802.3u standard covers these ...

  • Page 49

    Fast etherhub-12s user’s guide glossary 3 shielded twisted-pair (stp) 100 w category 5 twisted-pair wire covered with an external aluminum-foil or woven- copper shield designed to reduce excessive noise pick up or radiation. The stp cable refered to in this manual is also sometimes called screened t...

  • Page 50: Index

    Index 1 index a accton's fast etherhub-12s • 1-1 automatic partitioning • 1-3 automatic polarity detection • 1-3 c cable length precise cable length budgeting • 2-4 simplified cable length constraints • 2-4 certification • c-1 class ii repeater • 2-5, 3-3 configuring the network • 3-1 connecting mul...

  • Page 51

    Fast etherhub-12s user’s guide 2 index m maximum cable length • 2-4 mdi daisy-chain port • 3-2 n network connection mdi daisy-chain port • 2-3 mdi-x station port • 2-2 p port and cable assignments • b-1 port status indicators • 4-4 power cord specifications • d-4 power socket • 4-6 product features ...

  • Page 52

    Eh3012-tx 150114-101 e0197-r02.