Accu-Scope 3002 User Manual

Summary of 3002

  • Page 1

    Manual 73 mall drive, commack, ny 11725 • 631-864-1000 (p) • 631-543-8900 (f) www.Accu-scope.Com • info@accu-scope.Com 3002 microscope series.

  • Page 2: Contents

    Accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 2 contents safety notes .................................................................................................................. 3 care and maintenance ...........................................................

  • Page 3: Safety Notes

    Accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 3 safety notes 1. Open the shipping carton carefully to prevent any accessory, i.E. Objectives or eyepieces, from dropping and being damaged. 2. Do not discard the molded styrofoam container; the container should be re...

  • Page 4: Introduction

    Accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 4 introduction congratulations on the purchase of your new accu-scope ® microscope. Accu-scope ® microscopes are engineered and manufactured to the highest quality standards. Your microscope will last a lifetime if use...

  • Page 5: Components Diagram

    Accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 5 components diagram iris diaphragm adjustment lever interpupillary distance adjustment binocular viewing head coarse focus adjustment knob eyepieces objective mechanical stage illuminator housing on/off switch fine fo...

  • Page 6: Controls Diagrams

    Accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 6 controls diagrams diopter adjustment ring interpupillary distance adjustment condenser adjustment knob upper limit stage locking lever variable light intensity dial coarse focusing knob fine focusing knob.

  • Page 7: Controls Diagrams

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 7 controls diagrams (continued) y stage movement adjustment knob x stage movement adjustment knob fine focusing adjustment knob coarse focusing adjustment knob tension adjustment collar on/off sw...

  • Page 8: Assembly Diagram

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 8 assembly diagram the diagram below shows how to assemble the various components. The numbers indicate the order of assembly. Your microscope was preassembled by our factory technicians at our n...

  • Page 9: Assembly

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 9 assembly (continued) installing the binocular viewing head loosen the lock screw and carefully insert the binocular viewing head into the main body. Rotate the head so it is facing forward, the...

  • Page 10: Assembly

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 10 assembly (continued) installing the objectives adjust the coarse focus knob until the mechanical stage reaches its lowest limit position. Screw the 4×objective into the nosepiece from the left...

  • Page 11: Assembly

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 11 assembly (continued) connecting the power cord do not bend or twist the power cord. Before connecting the power cord, make sure the switch is off (o) as shown in ① (fig 8). Insert the female e...

  • Page 12: Assembly

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 12 assembly (continued) installing & replacing the lamp use only the specified halogen 6 volt 20 watt lamp (cat #3256) . Do not touch the halogen bulb with bare hands as it may shorten the lamp l...

  • Page 13: Adjustment

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 13 adjustment & operation adjusting the brightness connect the power supply and turn on the main switch ① (fig. 13) . Move the variable light intensity dial ② (fig 14) toward the front of the mic...

  • Page 14: Adjustment

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 14 adjustment & operation (continued) adjusting the focusing tension the tension of the coarse focusing knob has already been factory adjusted. If the handle is very heavy when focusing or the sp...

  • Page 15: Adjustment

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 15 adjustment & operation (continued) adjusting the condenser turn the condenser focus knob (fig. 17) to raise or lower the condenser. The condenser is raised when using high magnification object...

  • Page 16: Adjustment

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 16 adjustment & operation (continued) adjusting the interpupillary distance to adjust the interpupillary distance, hold the left and right eyetubes (fig. 19) while observing a specimen. Rotate th...

  • Page 17: Led Lamp Specifications

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 17 led lamp specifications the 3002-led-r microscope is equipped with a variable 1 watt rechargeable led lamp. The led lamp can last up to 5 hours on a single charge depending on the brightness l...

  • Page 18: Troubleshooting

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 18 troubleshooting problem cause solution led lamp does not light no power supply check the power cord or recharge the battery the led wire is disconnected reconnect the led wire or call your loc...

  • Page 19: Technical Specifications

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 19 technical specifications objective tube length 160mm viewing head monocular, binocular or trinocular head, 30°inclined; interpupillary distance 52-75 mm eyepiece wf 10x; 18mm field of view nos...

  • Page 20: Troubleshooting

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 20 troubleshooting under certain conditions, performance of this unit may be adversely affected by factors other than defects. If a problem occurs, please review the following list and take remed...

  • Page 21: Troubleshooting

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 21 troubleshooting (continued) image problems problem cause solution image moves while focusing specimen rises from stage surface secure the specimen in the slide holder revolving nosepiece is no...

  • Page 22: Troubleshooting

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 22 troubleshooting (continued) mechanical problems problem cause solution image will not focus with high power objective slide upside down turn the slide over so the coverglass faces up cover gla...

  • Page 23: Maintenance

    3002 microscope series accu-scope ® 73 mall drive, commack, ny 11725 • 631-864-1000 • www.Accu-scope.Com 23 maintenance please remember to never leave the microscope with any of the objectives or eyepieces removed and always protect the microscope with the dust cover when not in use. Service accu-sc...