Accu-Steam AT0H-3035 Owner's Manual

Manual is about: gas

Summary of AT0H-3035

  • Page 1

    Accu-steam ™ gas griddle owners manual important warranty information: for product warranty activation, the a ccu -s team ™ griddle start-up form and the product registration form must be submitted to accutemp products, inc. After installation of the appliance. A ccu -s team ™ griddle start-up form ...

  • Page 2

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page i important for your safety these installation instructions have been prepared for qualified gas equipment installation personnel, who should perform the initial field start-up and complete the equipment adjustments described in this manua...

  • Page 3: Document History

    At2t-3238-1 rev. C accu-ste am tm gas griddle owners manual page i document history current revision: – prior revision: none date: 2/28/06 date: none change initial release. Current revision: a prior revision: – date: 3/14/06 date: 2/28/06 change page 4 – added unpacking information. Page 5 – added ...

  • Page 4: Table Of Contents

    At2t-3238-1 rev. B accu-ste am tm gas griddle owners manual page ii table of contents document history i table of contents ii safety warnings 1 – 2 theory of operation 3 installation 4 – 10 operation 11 – 12 service and troubleshooting 13 – 15 gas conversion kit 16 gas griddle orifice reference tabl...

  • Page 5: Safety Warnings

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 1/29 safety warnings symbol definitions symbols are used to attract your attention to possible dangers. They are only effective if the operator uses proper accident prevention measures. Some of the symbols are boxed text, while other maybe...

  • Page 6: Safety Warnings (Cont.)

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 2/29 safety warnings (cont.) symbol icons below are definitions of symbol icons used in this manual: alert – notifies the reader of an important message/warning, usually a safety related message. Information – notifies the reader of import...

  • Page 7: Theory Of Operation

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 3/29 theory of operation introduction the a ccu -s team griddle is constructed and uses technology like no other griddle in the world. The diagram below is a cross-sectional view of the griddle. The griddle cooking surface is the top of a ...

  • Page 8: Installation

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 4/29 installation this installation must conform with local codes, or in the absence of local codes, with national fuel gas code, ansa/nfpa 54 , or the natural gas and propane installation code, csa b149.1 , as applicable. The appliance an...

  • Page 9: Installation (Cont.)

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 5/29 installation (cont.) provisions should be incorporated in the design of the kitchen, to ensure an adequate supply of fresh air for proper combustion and ventilation. When installing, never enclose the bottom of the unit with a raised ...

  • Page 10: Installation (Cont.)

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 6/29 installation (cont.) adequate means must be provided to limit the movement of the stand without depending on the connector and the quick-disconnect device or its associated piping to limit movement. The restraining device shall be mou...

  • Page 11: Installation (Cont.)

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 5/29 installation (cont.) provisions should be incorporated in the design of the kitchen, to ensure an adequate supply of fresh air for proper combustion and ventilation. When installing, never enclose the bottom of the unit with a raised ...

  • Page 12: Installation (Cont.)

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 7/29 installation (cont.) electrical requirements the electrical voltage requirement is listed on the data plate that is located on the front control panel. All standard accutemp gas griddles are supplied with power cord and plug that must...

  • Page 13: Installation

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 8/29 installation gas connection this griddle has been manufactured for use with the type of gas indicated on the data plate. Contact accutemp products technical & customer support department if your gas supply does not match the gas indic...

  • Page 14: Installation (Cont.)

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 9/29 installation (cont.) figure 2 adjust the regulator(s) as needed to comply with the pressures indicated on the griddle orifice and pressure specification label. See figure 2 for the orifice and pressure specification data. Figure 3 the...

  • Page 15: Installation (Cont.)

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 10/29 installation (cont.) a colored sheet copy of the a ccu -s team griddle start-up form and the griddle product registration form were enclosed in the gas griddle from the factory. Both of these documents must be completed and submitted...

  • Page 16: Operation

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 11/29 operation seasoning it is recommended that you clean your a ccu -s team griddle thoroughly before turning your unit on. To clean the griddle surface, just simply wash the cooking surface down with a solution of mild soap and water, a...

  • Page 17: Operation (Cont.)

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 12/29 operation (cont.) won’t change or vary by the location on the griddle surface. There are no hot or cold zones. Heat lamp it is normal for the heat light to cycle on and off. This light indicates when the main burners are energized. Y...

  • Page 18

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 13/29 service and troubleshooting no user-serviceable parts there are no user-serviceable parts. Accutemp-authorized service personnel should complete any servicing. Service performed by unauthorized personnel will void the warranty. Note ...

  • Page 19

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 14/29 service and troubleshooting (cont.) general service information basic troubleshooting griddle will not turn on make sure the griddle is plugged in and the “on/off” switch is in the on position. The power indicator light must be “on” ...

  • Page 20

    At2t-3238-1 rev. C accu-steam gas griddle owners manual page 15/29 service and troubleshooting (cont.) heat light will not come on make sure the griddle is not hotter than the temperature you have it set for. If you have turned down the temperature of the griddle, the heat light will not come on aga...

  • Page 21

    1 3 2 4 5 6 7 8 e d r : 0 80 s ca le : 1 :2 s he et 1 o f 1 c ti tle : r ev . D ra w in g n o. : s iz e: a t0 h -3 03 5 - g a s a p p li a n c e s td c o n v e r s io n k it a cc ut em p p ro du ct s, in c. 84 15 n . C lin to n p ar k fo rt w ay ne , i n 4 68 25 n am e d at e 1/ 03 /0 4 d ra w n c h...

  • Page 22

    At2t-3238-1 rev. C accu-steam tm gas griddle owners manual page 16 / 27 gas griddle orifice reference table for alititude and btu content note: this table represents the standard upper and lower ranges of btu per cubic foot content. There is no relationship between the natural gas btu content and th...

  • Page 23: At2A-2813-2

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m at2a-2813-2 24" x 24" griddle ext therm b b a d e f f g g g qty at2a-2813-24 qty at2a-2813-23 qty at2a-2813-22 qty at2a-2813-21 q...

  • Page 24: Exploded View Gas Griddle

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m 2 11 13 1 8 9 2 24 31 22 7 3 30 34 34 34 31 32 34 25 26 32 15 18 21 4 5 23 10 19 28 20 16 35 33 5 34 19 14 exploded view gas grid...

  • Page 25: At2A-2818-1

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m at2a-2818-1 combustion chamber 24" 20 10 22 1 9 20 2 20 6 14 23 11 23 14 6 3 20 3 20 20 20 8 7 2 21 18 5 a a 24 c 25 d b c d d d ...

  • Page 26: At2A-2818-2

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m at2a-2818-2 combustion chamber 36" 20 2 15 2 15 20 9 20 10 6 14 23 11 23 14 6 13 21 20 20 7 8 20 5 18 24 c 25 d edr: 045f scale: ...

  • Page 27: At2A-2818-3

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m at2a-2818-3 combustion chamber 48" 22 20 18 5 10 2 15 2 20 20 15 6 14 23 13 12 16 23 14 6 17 6 4 20 21 20 8 7 4 20 24 c 25 d edr:...

  • Page 28

    .0 7 - . 1 0 g f g d e t a il a s c a l e 3 : 1 c e r a m ic s u r f a c e ig n it o r r o d s e n s o r r o d l o w e s t p o in t s o f c e r a m ic s u r f a c e g r o u n d r o d t o c o n t a c t n o t e : g r o u n d r o d t o b e p o s it io n e d o n t o g .1 6 .1 2 ± .0 5 d e t a il b s c a...

  • Page 29: At2A-2850-2

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m at2a-2850-2 gas control valve assembly propane otherwise same as at2a-2850-1 11 12 a a b b 1 6 7 4 3 13 10 5 12 2 8 9 11 9 2 14 c...

  • Page 30: At2A-2819-1

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m 12 2 3 9 1 11 10 4 8 13 15 14 24 5 23 24 24 6 at2a-2819-1 control panel 24" 16 21 25 25 27 30 31 32 28 a b b b b a a c 34 d e f f...

  • Page 31: At2A-2819-2

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m at2a-2819-2 control panel 36" otherwise same as at2a-2819-1 f 21 use this weld stud for at0a-3506-1 ground connection k at2a-2819...

  • Page 32: At2A-2916-1

    Unless otherwise specified, dimensions: inches bends: 90 tolerances: angular 1° 2 place decimal .02 3 place decimal .005 t.I.R .005 √125 micro inches gd&t per ansi y14.5m at2a-2916-1 13 8 10 4 note: 1. Manufacturing date code reflects the date of manufacture of the rod assembly. 2. Date code to be p...

  • Page 33

    1/ 19 /0 5 d o n ot s ca le d ra w in g fi ni sh : m at er ia l: c om m en ts : 1/ 19 /0 5 e d r : 0 83 s ca le : 1 :2 s he et 1 o f 1 b ti tle : r ev . D ra w in g n o. : p ro j. E ng r. G . S e it z s iz e: a t2 t- 30 41 b g a s g r id d le s c h e m a ti c fo rt w ay ne , i n 4 68 25 n am e d at ...

  • Page 34: Warranty

    Warranty limited warranty one year – parts and labor u.S. & canada only accutemp products, inc. (accutemp) warrants that your accutemp equipment will be free of defects in material and workmanship under normal use for a period of twelve (12) months from installation or fifteen (15) months from date ...

  • Page 35

    Fs 3805-0804 page 1 of 4 gas griddle periodic maintenance (pm) recommendations note: accutemp-approved service providers should complete these pm tasks. Pm task descriptions daily items bi- annual items annual items 1. Verify that the griddle is level and properly located under the hood. X 2. Verify...

  • Page 36

    Fs 3805-0804 page 2 of 4 pm task descriptions daily items bi- annual items annual items 10. Inspect the burner venturi tubes for foreign particles. Wipe out with a mild detergent and warm water and rinse with clean water. X x 11. Inspect combustion chamber and the burner tiles. If water stains are p...

  • Page 37

    Fs 3805-0804 page 3 of 4 gas griddle periodic maintenance (pm) recommendations (cont.) accutemp products, inc. Gas pressures the griddle requires the proper gas pressure setting to operate properly. All pressure readings should be taken after the unit has reached a temperature of at least 200°f and ...

  • Page 38

    Fs 3805-0804 page 4 of 4 gas griddle periodic maintenance (pm) recommendations (cont.) accutemp products, inc. Igniter probe assembly the igniter probes ignite and sense that the pilot burner is operational. Depending on the kitchen- cooking environment, geographic location and cleaning solutions us...

  • Page 39

    Accu-steam ™ gas griddle start-up form accutemp products, inc. Location: __________________ address: ___________________________ city: _____________ state: _______ zip: _________ ph#______________ serial number ________ model number: ____________________________ service agency: ____________________ ...