    Accutemp products, inc. · 8415 north clinton park · fort wayne, in 46825 ·800 210-5907 · accutemp.Net service manual accu-steam gas g2 griddle improper installation, alteration, adjustment,service, cleaning or maintenance of this commercial appliance could result in property damage, serious injury o...

  • Page 2

    Accu-steam™ g2 gas service manual page 2 sp8042-1609 toll free 800.480.0415 office 260.469.3040 fax 260.493.8914 email service@accutemp.Net web site www.Accutemp.Net.

  • Page 3: Warning Symbol Definitions

    Accu-steam™ g2 gas service manual page 3 sp8042-1609 warning symbol definitions symbol definitions symbols are used to attract your attention to possible dangers. They are only effective if the operator uses proper accident prevention measures. Some of the symbols are boxed text; while others maybe ...

  • Page 4: Energized Equipment.

    Accu-steam™ g2 gas service manual page 4 sp8042-1609 electrical shock hazard while working on energized equipment. Unplug equipment prior to removing any components effected by electricity. Personnel injury hazard while picking up or moving heavy equipment. Always use at least 2 people and proper li...

  • Page 5: Warning

    Accu-steam™ g2 gas service manual page 5 sp8042-1609 do not store or use gasoline, or any other flammable vapor and/or liquids in the vicinity of this or any other appliance. Warning in the event of a power failure, do not attempt to operate this appliance. Warning improper installation, adjustment,...

  • Page 6: Warning & Caution Notes

    Accu-steam™ g2 gas service manual page 6 sp8042-1609 warning & caution notes only qualified service technicians should perform maintenance on this equipment. Warning caution griddle may have sharp edges..

  • Page 7: Table of Contents

    Accu-steam™ g2 gas service manual page 7 sp8042-1609 table of contents sequence of operation ............................................................................................................. Specification sheet ................................................................................

  • Page 8: Sequence of Operation

    Accu-steam™ g2 gas service manual page 8 sp8042-1609 sequence of operation 1. When the g2 griddle is plugged in, ac line voltage is supplied to the primary side of the transformer. 2. The voltage out of the secondary side of the transformer is 24vac nominal. Yellow and blue wires out of the transfor...

  • Page 9: Griddle Specifications Sheet

    Accu-steam™ g2 gas service manual page 9 sp8042-1609 griddle specifications sheet 13. If the dc voltage level is detected before 4 seconds and is at a high enough level the ignition module will continue to hold the main gas valve open. 14. If the dc voltage level is not high enough within the 4 seco...

  • Page 10: Troubleshooting Guide

    Accu-steam™ g2 gas service manual page 10 sp8042-1609 troubleshooting guide unit on? Correct voltage check internal voltage a b c no no breaker on? Unit plugged in? Yes yes no no fault light / error code? D e overtemp? Yes heat on? H i no unit heating up? Heat light on? Yes no no error code e001? E0...

  • Page 11: Troubleshooting Guide

    Accu-steam™ g2 gas service manual page 11 sp8042-1609 troubleshooting guide a power cord disconnected confirm proper voltage at outlet. Plug in power cord. B breaker is tripped unplug griddle and check line voltage at outlet. Reset breaker. C temperature controller if 24vac is on secondary side of t...

  • Page 12: Troubleshooting Guide

    Accu-steam™ g2 gas service manual page 12 sp8042-1609 troubleshooting guide g fault light on if burners did not ignite, replace fault timer. If burners did ignite and unit heating, check for short to ground in the white wire connected to the fault indicator lamp. H heat light not on if griddle is wa...

  • Page 13: Digital Controller

    Accu-steam™ g2 gas service manual page 13 sp8042-1609 digital controller change cooking/ default/ preset temperatures 1. Turn the griddle on by pressing the on/off (s5) button. 2. Hold the up (s1) arrow in for 3 seconds until all 3 lights start to flash. 3. Press the up (s1) or down (s4) arrow until...

  • Page 14: Digital Controller

    Accu-steam™ g2 gas service manual page 14 sp8042-1609 digital controller operating mode when power is applied to the control, the control will configure itself to operate in accordance with the parame - ters stored in memory. These parameters may be adjusted using manager’s mode. Reset pressing and ...

  • Page 15

    Accu-steam™ g2 gas service manual page 15 sp8042-1609 main components and purpose reference transformer at0e-2662-5 -steps down the line voltage to approximately 24vac nominal timer, ignition fault at0e-2500-3 -controls fault light. -if signal is lost from the ignition module the timer causes igniti...

  • Page 16

    Accu-steam™ g2 gas service manual page 16 sp8042-1609 parts identification, removal and installation fuse .75 amp 250v at0e-2731-4 1. Unplug from wall receptacle. 2. Lower front access panel by removing the screws in the upper corners of the panel. 3. Replace fuse. Hi-limit rtd temp sensor rtd ignit...

  • Page 17

    Accu-steam™ g2 gas service manual page 17 sp8042-1609 parts identification, removal and installation digital control board at0e-3625-5 1. Unplug from wall receptacle. 2. Lower front access panel by removing the screws in the upper corners of the panel. 3. Locate the main control board. Take note of ...

  • Page 18

    Accu-steam™ g2 gas service manual page 18 sp8042-1609 parts identification, removal and installation heat lamp at0e-1800-2 hi-limit lamp at0e-1800-2 fault lamp at0e-1800-2 1. Unplug from wall receptacle. 2. Lower front access panel by removing the screws in the upper corners of the panel. 3. Locate ...

  • Page 19

    Accu-steam™ g2 gas service manual page 19 sp8042-1609 parts identification, removal and installation gas valve at2e-1806-2 ignition control module at2e-1807-1 1. Unplug from wall receptacle. 2. Lower front access panel by removing the screws in the upper corners of the panel. 3. Locate the module an...

  • Page 20

    Accu-steam™ g2 gas service manual page 20 sp8042-1609 parts identification, removal and installation flame sensor at2e-4717-1 igniter at2e-4716-1 infrared burner at2b-2099-2 1. Unplug from wall receptacle. 2. Lower front access panel by removing the screws in the upper corners of the panel. 3. Remov...

  • Page 21: Rtd Testing

    Accu-steam™ g2 gas service manual page 21 sp8042-1609 parts identification, removal and installation temperature sensor, 1000 Ω rtd at0e-2885-8 (black heat shrink) 1. Unplug from wall receptacle. 2. Lower front access panel by removing the screws in the upper corners of the panel. 3. Locate and remo...

  • Page 22: Ignition System Testing

    Accu-steam™ g2 gas service manual page 22 sp8042-1609 ignition system testing when trouble shooting ignition problems it is absolutely imperative to start off by taking incoming/outgoing gas pressure and to get a reading from the flame sensor. These three measurement are the most useful readings a t...

  • Page 23: Ignition System Testing

    Accu-steam™ g2 gas service manual page 23 sp8042-1609 ignition system testing gas pressures when trouble shooting ignition problems it is absolutely imperative to start off by taking incoming/outgoing gas pressure and to get a reading from the flame sensor. These three measurement are the most usefu...

  • Page 24: Preventative Maintenance

    Accu-steam™ g2 gas service manual page 24 sp8042-1609 preventative maintenance general gas appliance periodic maintenance (pm) recommendations accutemp products, inc. Note: some information is not relevant for all appliances. Page 1 of 4 2/15/10 pm task description general items bi-annual items annu...

  • Page 25

    Accu-steam™ g2 gas service manual page 25 sp8042-1609 s c h e m a t ic, g 2 g r iddl e f o rt w ayn e, i n 46 8 25 at2t-3912 -1 rev a 8 4 1 5 n . C lin to n p a rk a ccu t em p p ro d u ct s, i n c. At2t-3912-1 120v-240v accu-steam g2 gas griddle yel o rn br n vi o b rn yel b lu yel b lu r ed or n y...

  • Page 26

    Accu-steam™ g2 gas service manual page 26 sp8042-1609 accu-steam™ g2 electric installation and operators manual mp5018-1605 page 4 limited warranty one year parts and laborone year parts and labor accutemp products, inc. ( accutemp ) warrants that your accutemp equipment will be free of defects in m...

  • Page 27: Notes

    Accu-steam™ g2 gas service manual page 27 sp8042-1609 notes ____________________________________________ ____________________________________________ ____________________________________________ ____________________________________________ ____________________________________________ _______________...