AccuLine 40-6515 Instruction Manual - page 14
14
©2007 Johnson Level & Tool
(d) Detection
1. Coarse detection
• Aim the receiving window at the
rotating laser instrument. Loosen the
clamp bolt and move the instrument
up and downwards to receive the
laser scanning signals transmitted by
the rotating laser instrument.
• When the instrument displays like Fig.
(A), move the instrument slightly down-
wards as indicated by the arrow. When
it displays like Fig. (B), move it slightly
upwards as indicated by the arrow.
• When Fig. (C) is displayed, the instrument is at the right position.
• Tighten the clamp bolt and mark the position of the object on the rabbet.
This mark will be the horizontal reference of the coarse detection.
2. Fine detection
1. power symbol
2. fine detection symbol
• Press coarse/fine detection button. The
instrument is ready for fine detection.
• Move the instrument slightly up and
downwards like the coarse detection
procedure.
• When the instrument displays like Fig 6, it is at the right position.
• Tighten the clamp bolt and mark the position of the object on the
rabbet. This mark will be the horizontal reference of the fine detection.
Figure 6