Accurate Technology Digi-Stop User Manual

Manual is about: complete digital stop and fence system for chop saws, radial arm saws, and miter saws

Summary of Digi-Stop

  • Page 1

    User manual for: digital readout firmware version d 2.000 & higher digi-stop™ digi-stop.

  • Page 2: Warranty

    Manual part # 800-1070-001, rev g, 10-2008 page 2 of 16 warranty accurate technology, inc., warrants this product against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon notification of a defect, accurate technology, inc., shall have the option to repai...

  • Page 3: Table Of Contents

    Accurate technology digistop page 3 of 16 table of contents s ection 1 g eneral i nformation .......................................................... 4 introduction.................................................................................................. 4 what this manual includes...........

  • Page 4: Ection

    Manual part # 800-1070-001, rev g, 10-2008 page 4 of 16 s ection 1 g eneral i nformation introduction digi-stop is a complete digital stop and fence system for chop saws, radial arm saws, and miter saws. It is the consumer model of accurate technology’s prostop™ stop & fence system. The readout has ...

  • Page 5: Digi-Stop Parts

    Accurate technology digistop page 5 of 16 digi-stop parts each digi-stop is shipped in two packages. The first contains the fence extrusion with the scale attached. The second package contains the digital stop and some installation hardware. Pictured below are parts that will be referred to througho...

  • Page 6: Ection

    Manual part # 800-1070-001, rev g, 10-2008 page 6 of 16 s ection 2 i nstallation assembly & mounting digi-stop is easy to install. By following the basics of good installation reliable, error-free operation can be expected. 1. Carefully slide the encoder onto the scale. 2. Loosen the locking knob an...

  • Page 7: Calibration

    Accurate technology digistop page 7 of 16 calibration once installed, digi-stop can be calibrated easily and quickly. The following is an example of calibrating digi-stop on a cutoff saw application. Other installations follow the same general procedure. 1. Cut a small part (approximately 8 inches) ...

  • Page 8: Changing The Batteries

    Manual part # 800-1070-001, rev g, 10-2008 page 8 of 16 changing the batteries a low battery indicator will appear in the lower left corner of the lcd. When battery voltage drops below approximately 2.6v the readout will turn itself off until the batteries are replaced. To replace the battery remove...

  • Page 9: Ection

    Accurate technology digistop page 9 of 16 s ection 3 o peration readout keys key timing the keys pictured above, are found on all digi-stop readouts, and some of them have multiple functions. Timing, which is how long a key is depressed, and the combination of the keys pressed is important. This man...

  • Page 10: Reverse Readings

    Manual part # 800-1070-001, rev g, 10-2008 page 10 of 16 illuminated bar indicates an additional 1/64 of an inch of measurement.) for better resolution, switch to 1/32 or 1/64 mode. For the best resolution and accuracy switch to a decimal mode – inches or millimeters.. When the measurement is greate...

  • Page 11: Readout Lock Mode

    Accurate technology digistop page 11 of 16 readout lock mode to activate the lock function press and hold the on / off key and then momentarily press the units key. The word lock lock lock lock will appear in the upper left corner of the readout. When lock lock lock lock is displayed, the + , datum ...

  • Page 12: Circuit Board

    Manual part # 800-1070-001, rev g, 10-2008 page 12 of 16 keys to provide a different offset. Moving the stop in either direction will display the distance moved from the initial inc starting point (plus any offset). To complete another incremental measurement from the new position, momentarily press...

  • Page 13: Readout

    Accurate technology digistop page 13 of 16 readout programming several functions of the digi-stop readout is user programmable. The following describes what features and functions are available and how to change the factory defaults to customize your digi-stop system.. To enter programming mode: 1. ...

  • Page 14

    Manual part # 800-1070-001, rev g, 10-2008 page 14 of 16 programming parameters the digi-stop readout programming parameters are listed below. Values in [ ] are the available range of values that can be entered for that parameter. Factory defaults are shown in bold red . Pr 1 – datum key [ 0 to + 99...

  • Page 15: Frequently Asked Questions

    Accurate technology digistop page 15 of 16 frequently asked questions what f/w (firmware) version do i have? The readout will display d 2.Xxx on power up. This is the firmware version of your readout . What does no enc no enc no enc no enc mean? If the encoder cable is unplugged from the readout , n...

  • Page 16: American Made Product

    Manual part # 800-1070-001, rev g, 10-2008 page 16 of 16 thank you for choosing an american made product accurate technology, inc. 270 rutledge rd. Unit e fletcher, nc 28732 usa 828.654.7920 please register your product at: http://www.Digi-kit.Com/registration.Htm this manual is available online at:...