Accurate Technology DigiStop-10 Installation & Operation Manual

Manual is about: Digi-Stop series

Summary of DigiStop-10

  • Page 1

    Digi-stop ™ installation & operation.

  • Page 2: Warranty

    Manual part # 800-1070-001 rev 10-2016 page 2 of 20 warranty accurate technology, inc., warrants this product against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon notification of a defect, accurate technology, inc., shall have the option to repair or...

  • Page 3: Table Of Contents

    Accurate technology digi-stop page 3 of 20 table of contents s ection 1 g eneral i nformation .................................................................. 4 introduction....................................................................................................... 4 about this manual ....

  • Page 4: Ection

    Manual part # 800-1070-001 rev 10-2016 page 4 of 20 s ection 1 g eneral i nformation introduction digistop is a digital stop & fence system. It is ideal for use on miter saws, chop saws, radial arm saws or any other application where a moveable stop along a fixed back fence is desired. It has been d...

  • Page 5: Specifications

    Accurate technology digi-stop page 5 of 20 specifications measuring range 1 : digistop4 up to 50 inches (1.3 meters) digistop-8 up to 94 inches (2.4 meters) digistop-10 up to 116 inches (2.9 meters) accuracy 2 : +/- 0.015 inches (0.4 mm) resolution .1inch .1mm or .01inch .01mm or .001inch .01mm or 1...

  • Page 6: Digi-Stop Parts

    Manual part # 800-1070-001 rev 10-2016 page 6 of 20 digi-stop parts each digi-stop is shipped in one or two packages (depending on the model). The first contains the fence extrusion with the scale attached. The second package (if necessary) contains the digital stop and installation hardware. Pictur...

  • Page 7: Ection

    Accurate technology digi-stop page 7 of 20 s ection 2 i nstallation mounting the fence assembly 1. Align the fence assembly adjacent to the saw (scale is to the rear of the fence). 2. Mark a line on the table top, along the front edge of the fence. 3. Remove the fence assembly and mark a second line...

  • Page 8: Calibration

    Manual part # 800-1070-001 rev 10-2016 page 8 of 20 calibration 1. Check to be sure installation of all parts is complete, all fasteners are secure and the encoder is plugged into the readout. 2. Cut a small part (approximately 8 inches) using the stop. Do not move the stop until this procedure is c...

  • Page 9: The Lcd Display

    Accurate technology digi-stop page 9 of 20 the lcd display the above figure illustrates all the segments available on the lcd. (not all segments are used on digi-stop systems) pressing and holding the on / off and units key for 10 seconds with power off will perform a full segment lcd test, display ...

  • Page 10: Ection

    Manual part # 800-1070-001 rev 10-2016 page 10 of 20 s ection 3 o peration readout keys key timing the keys pictured above, are found on all digi-fence readouts. Some of them have multiple functions! Timing, which is how long a key is depressed, and the combination of the keys pressed is important. ...

  • Page 11

    Accurate technology digi-stop page 11 of 20 additional 1/64 of an inch measurement making the true, full resolution measurement 2 13/64ths. Some users find this resolution unnecessary and prefer the 16ths or 32nds mode instead. For better resolution, switch to 64ths mode. For the best resolution swi...

  • Page 12: Readout Lock

    Manual part # 800-1070-001 rev 10-2016 page 12 of 20 readout lock to activate the lock function press and hold the on / off key and then momentarily press the units key. The word lock will appear in the upper left corner of the readout. When lock is displayed, the + , datum and – keys become inactiv...

  • Page 13: Auto On/off

    Accurate technology digi-stop page 13 of 20 auto on/off to prolong battery life, the readout has a built-in function that turns off the readout after a period of no movement or key activity. The auto on/off function is programmable from 0 (always on), to 240 (minutes) before entering sleep mode. Pre...

  • Page 14: Circuit Board Jumpers

    Manual part # 800-1070-001 rev 10-2016 page 14 of 20 circuit board jumpers the digi-stop readout has several user configurable jumpers consisting of three pins and a ‘shorting block or jumper’. The center of these three pins is ‘common’. One end pin is labeled a and the other end pin is labeled b. J...

  • Page 15: Readout Programming

    Accurate technology digi-stop page 15 of 20 readout programming several functions of the digi-stop readout are user programmable. The following describes what features and functions are available and how to change the factory defaults to customize your digi-fence system.. Review key timing described...

  • Page 16: Programming Parameters

    Manual part # 800-1070-001 rev 10-2016 page 16 of 20 programming parameters the readout programming parameters are listed below. Values in [ ] are the available range of values that can be entered for that parameter. Factory defaults are shown in bold red . Note: programming parameters are not seque...

  • Page 17

    Accurate technology digi-stop page 17 of 20 pr11 – readout measurement units ······································· [ 0 to 6] this parameter controls the type of measuring units the readout displays when the units key is pressed. The table below illustrates the possible combinations of measuring un...

  • Page 18: Frequently Asked Questions

    Manual part # 800-1070-001 rev 10-2016 page 18 of 20 frequently asked questions what f/w (firmware) version do i have? The readout will display d 2.Xxx on power up. This is the firmware version of your readout . The readings are “backwards”? You can change reading direction of the digi-fence by chan...

  • Page 19

    Accurate technology digi-stop page 19 of 20

  • Page 20: Thank You For Choosing An

    Manual part # 800-1070-001 rev 10-2016 page 20 of 20 thank you for choosing an american made product accurate technology, inc. 270 rutledge rd. Unit e fletcher, nc 28732 usa 828.654.7920 please register your product at: http://www.Proscale.Com/registration.Htm this manual is available online at: www...