AccuRelief MiniTENS ACRL-1000 User Manual

Manual is about: Pain Relief System

Summary of MiniTENS ACRL-1000

  • Page 1

    Mini tens natural, drug-free pain relief 20 minute treatment – single patient use model acrl-1000 user manual clinically proven.

  • Page 2

    This manual is valid for the accurelief™ mini tens acrl-1000 this instruction manual is published by carex health brands. Carex health brands reserves the right to improve and amend this manual at any time without prior notice. Amendments may however be published in new editions of this manual. All ...

  • Page 3

    3 table of contents introduction .............................................................................................................................. 4 important safety precautions and warnings ............................................................................... 6 product struct...

  • Page 4

    4 perception. Tens does not cure any physiological problem. It only helps control the pain. Tens does not work for everyone. However, in most patients, it is effective in reducing or eliminating the pain, allowing for a return to normal activity. How does tens work? Scientific theory suggests that e...

  • Page 5

    5 what conditions can tens help relieve? Tens provides pain relief for a number of different pain conditions associated with exercise, normal work and household activities. This product is designed for temporary relief of muscle and joint bone pain in the: n neck n waist n shoulder n upper extremiti...

  • Page 6

    6 safety symbols used in this manual indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in serious injury and equipment damage. Indicates a potentially hazardous s...

  • Page 7

    7 warning consult with your physician before using this device, because the device may cause lethal rhythm disturbances in certain susceptible individuals. Do not use this device under these conditions: n if you have a cardiac pacemaker, active implanted defibrillator, or other implanted metallic or...

  • Page 8

    8 do not use this device during these activities: n bathing or showering; n sleeping; n driving, operating machinery or any activity in which electrical stimulation can put you at risk for injury. Pain management warnings n if you have had medical or physical treatment for your pain, consult with yo...

  • Page 9

    9 n both sides of the thorax simultaneously (lateral or front and back), or across your chest because the introduction of electrical current may cause rhythm disturbances, which could be lethal. Caution warnings and precautions regarding the pads n do not bend or fold because the pads may not functi...

  • Page 10

    10 n pads should not be placed simultaneously on the soles of both feet. N pads should not be placed simultaneously on the calves of both legs. N do not share pads with another person. This may cause a skin irritation or infection. Pads are intended for use by one person. N do not place or relocate ...

  • Page 11

    11 n the size, shape and type of pads may affect the safety and effectiveness of electrical stimulation. Use only the accurelief™ brand electrode (accurelief™ supply kit - acrl-0002) designed specifically for the acrl-1000 mini tens device. General precautions n the long-term effects of electrical s...

  • Page 12

    12 n this stimulation should not be applied over the menstruating or pregnant uterus. N this stimulation should not be applied over areas of skin that lack normal sensation. N keep unit out of reach of young children. The unit contains small pieces that may be swallowed. Contact your physician immed...

  • Page 13

    13 product structure mini tens back of unit front of unit.

  • Page 14

    14 1. Remove the larger + button from the gel pad. 2. Using a coin, turn the battery cover counterclockwise to open. 3. Place the battery in the battery compartment so the positive terminal ( + ) faces upward. 4. Close the battery cover by turning it clockwise. Then snap the electrode pad to the bac...

  • Page 15

    15 step 1 cleaning of skin clip excess hair from the treatment area. Wash area with soap and water, and dry completely. Step 2 preparation of the tens unit each gel pad is pre-fixed with a stud to connect to the back of the device, and is protected by a transparent film. Attach the gel pads to the b...

  • Page 16

    16 step 4 operating the tens unit once gel pads are securely placed on the skin, the tens unit is ready for use. 1. To power on the unit, press and hold the “ + ” button for 3 seconds until you hear a mildly audible long beep. 2. Use the “ + ” button and the “ – ” button to adjust the intensity to a...

  • Page 17

    17 gel pad positioning the tens unit can treat many different types of pain. This page shows diagrams of recommended placement of gel pads for the most common forms of pain. For other areas of pain, place the gel pads on either side of the area of pain. Please note: never place the gel pads on the h...

  • Page 18

    18 n always use the protective film provided and then store in sealed package when the gel pads are not in use. N do not use any chemical to clean the device or the gel pads. If you need to clean the device, wipe with a damp, lint-free cloth. N do not let the gel pads dry out or expose them to direc...

  • Page 19

    19 technical specifications type: mini tens acrl-1000 power supply: dc3.0v, 1×cr2032 wave form: bi-phase square pulse wave frequency: 2~125hz pulse width: 100~200 μs output voltage: 0 – 70ma output intensity level: 0~15 levels treatment time: 20 minutes operating conditions: 50°f~104°f (10°c ~ 40°c)...

  • Page 20

    20 troubleshooting problem possible causes possible solution the unit cannot power on is the battery exhausted? Replace the battery. Is the battery installed correctly? Insert the battery observing polarity. Stimulation weak or cannot feel any stimulation gel pads are dried out or dirty. Replace wit...

  • Page 21

    21 with the increased number of electronic devices such as computers and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a poten...

  • Page 22

    22 guidance and manufacturer’s declaration – electromagnetic emissions accurelief™ electrical stimulators are intended for use in the electromagnetic environment specified below. The customer or the user of these electrical stimulators should assure that it is used in such environment. Emissions tes...

  • Page 23

    23 guidance and manufacturer’s declaration – electromagnetic immunity accurelief ™ electrical stimulators are intended for use in the electromagnetic environment specified below. The customer or the user of these electrical stimulators should assure that it is used in such environment. Immunity test...

  • Page 24

    24 guidance and manufacturer’s declaration – electromagnetic immunity accurelief™ electrical stimulators are intended for use in the electromagnetic environment specified below. The customer or the user of these electrical stimulators should assure that it is used in such environment. Immunity test ...

  • Page 25

    25 note i at 80 mhz ends 800 mhz the higher frequency range applies. Note 2 these guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. A field strengths from fixed transmitters, such as base stations for...

  • Page 26

    26 recommended separation distances between portable and mobile rf communications equipment and the device the device is intended for use in an electromagnetic environment in which radiated rf disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interf...

  • Page 27

    27 for transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where p is the maximum output power rating of the transmitter in watts (w) according to the ...

  • Page 28

    28 explanation of symbols type bf applied part disposal in accordance with directive 2002/96 ec (weee) refer to instruction manual caution keep dry.

  • Page 29

    29 warranty please contact carex health brands or the device center in case of a claim under the warranty. If you have to send in the unit, enclose a copy of your receipt and clearly state the defect. The following warranty terms apply: 1. The warranty period for the device is one year from date of ...

  • Page 30

    30 limited one year warranty your accurelief™ mini tens device is warranted for a period of 1 year from the date of original purchase. Electrodes pads are excluded from this warranty. Carex health brands sells its products with the intent that they are free of defects in manufacture and workmanship ...

  • Page 32

    Manufactured for: carex health brands tel: 800-328-2935 customerservice@carex.Com copyright 2014 by carex health brands.