ACDelco AC-G0004 Instruction Manual

Manual is about: 5500 Surge Watts / 5000 Running Watts ELECTRIC START PORTABLE GENERATOR

Summary of AC-G0004

  • Page 1

    Model # ac-g0004 5500 surge watts / 5000 running watts electric start portable generator instruction manual thank you for purchasing this high quality acdelco model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator. This manual provides important information on properl...

  • Page 2

    Acdelco model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator features: • 5500 surge output • 5000 running watts • 120/240 volt operation • 11 hp engine, 4 stroke ohv • air cooled • 6.5 gal. Fuel tank w/gauge • avr automatic voltage regulation • electric and recoil s...

  • Page 3

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 3 table of contents recognize safety symbols, words and labels.................................................................................................... 4 important safety instructions......................

  • Page 4

    Recognize safety symbols, words and labels what you need to know about safety instructions warning and important safety instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating ...

  • Page 5

    Notice regarding emissions: engines certified to comply with california and u.S. Epa emission regulations for sore (small off road equipment) are certified to operate on regular unleaded gasoline and may include the following emission control systems: three-way catalyst (twc) (if equipped), and engi...

  • Page 6

    Powerful voltage: this generator produces powerful voltage, which can result in electrocution. • always ground this generator before using it. (see “ground the generator” section in this manual). • only electrical devices should be plugged into this generator, either directly or with an extension co...

  • Page 7

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 7.

  • Page 8

    In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator. Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 8.

  • Page 9

    Package contents the following items are supplied with this acdelco model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator. Verify that all items are included. Stop! If there are missing items, call 1-866-460-9437, monday - friday, 8 am - 4 pm central time for custome...

  • Page 10

    Generator components observe the locations and functions of the various components and controls of this generator. (1) 120/240 volt ac outlet - used for connecting electrical devices that run on 120 and/or 240 volt, 60 hz, single phase, ac current. (2) ground terminal - used for connecting grounding...

  • Page 11

    Preparing the generator for use using this generator for the first-time stop! The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform these steps can damage this generator and/or shorten its life. If still unsure about how to pe...

  • Page 12

    Step 2 - add gasoline gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns. • do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, et...

  • Page 13

    Step 3 - ground the generator failure to properly ground this generator can result in electrocution. Ground this generator by tightening the grounding nut against a grounding wire as illustrated in figure 3. A no. 12 awg (american wire gauge) stranded copper wire is generally an acceptable grounding...

  • Page 14

    Step 2 - verify gas level before starting this generator, verify that there is sufficient gasoline in the fuel tank. The fuel gauge, located on the top of this generator, indicates the gas level currently in the fuel tank. If necessary, add fresh unleaded gasoline with an octane rating of 87 or high...

  • Page 15

    To start this generator: 1. Confirm that there are no electrical devices connected to this generator. Connected devices may increase the difficulty in starting the engine. 2. Confirm that this generator is properly grounded. (see “ground the generator” section of this manual.) 3. Turn the fuel valve...

  • Page 16

    Using the generator after the engine has been running for several minutes, electrical devices may be connected to this generator. Ac usage electrical devices running on ac current may be connected according to their wattage requirements. The rated (running) and surge wattage for this acdelco model a...

  • Page 17

    Electrical device rated (running) watts additional surge watts air compressor (1 hp) 1500 3000 air compressor (1 - 1/2 hp) 2500 2500 airless sprayer (1/3 hp) 600 1200 box fan 300 600 clock radio am/fm 300 0 coffee maker 1500 0 computer w/17 inch monitor 800 0 deep freezer 500 500 electric drill (1/2...

  • Page 18

    Do not connect 50hz or 3-phase loads to this generator. Figure 8 - outlets available on this generator, from left to right, 12v dc, 240/120 ac (nema l14-30 plug) and 120v ac. Some notes about power cords long or thin cords can require more wattage from a generator to power an electrical device. Figu...

  • Page 19

    To connect 12 volt batteries to the dc outlet: 1. Connect one charging wire to the positive terminal of the battery and the other charging wire to the negative terminal of the battery. 2. Connect the free end of the positive wire to the positive side of the outlet on this generator. 3. Start this ge...

  • Page 20

    Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance procedures. Keep heat, sparks and flame away. Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction whi...

  • Page 21

    Figure 11 - checking the oil changing/adding oil the oil level in this generator should be checked before each use. (see figure 10.) when the oil level is low, add oil until the level is sufficient to operate this generator. The oil capacity for this acdelco model ac-g0004 5500 surge watts / 5000 ru...

  • Page 22

    Figure 12 - draining oil figure 13 - adding oil air filter maintenance routine maintenance of the air filter helps maintain proper airflow to the carburetor. Occasionally verify that the air filter is free of excessive dirt. The air filter will require more frequent cleaning when operating this gene...

  • Page 23

    3. Using a rag or brush, clean the cup of all sediment. 4. Reinstall the fuel filter cup. Figure 15 - removing the fuel filter cup spark plug maintenance the spark plug is essential for proper engine operation. The spark plug should be intact, free of deposits, and properly gapped. A bad or incorrec...

  • Page 24

    Figure 16 - removing the spark plug figure 17 - measuring the spark plug gap emptying the fuel tank to store this generator for extended time, drain the gasoline from the fuel tank. To drain gasoline from this generator: 1. Turn the fuel valve to the “off” position. 2. Remove the fuel filter cup. (s...

  • Page 25

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 25 troubleshooting important: if trouble persists, call our customer help line at 1-866-460-9437, monday - friday, 8 am - 4 pm central time. Symptom cause solution the key is set to "off." turn the key to "batt st...

  • Page 26

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 26 specifications acdelco model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator generator type brush, revolving magnetic field, self exciting, 2-pole, single phase ac output rated ...

  • Page 27

    Exploded view and parts list model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 27.

  • Page 28

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 28 parts list item part qty description item part qty description 1 188fd 1 gasoline engine 50 37880 1 low oil indicator 2 41100 1 frame complete 51 37310/2.8gf-3 1 control panel 3 41310/4gf-3 2 bottom rubber moun...

  • Page 29

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator wiring diagram model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 29.

  • Page 30

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 30 notes:.

  • Page 31

    Warranty limited warranty for acdelco generators from new buffalo corporation. Remember to save your receipt and to accurately fill out and mail your product registration card. You must provide proof of purchase for all warranty work. Acdelco generators are warranted to be free from defects in mater...

  • Page 32

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 32.

  • Page 33

    Portability kit installation the manufacturer recommends when using your acdelco generator for recreational or utility functions that you properly install the portability kit included with your generator purchase. All acdelco generator models include a portability kit for optional installation. Port...

  • Page 34

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 34.

  • Page 35

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 35.

  • Page 36

    Model ac-g0004 5500 surge watts / 5000 running watts electric start portable generator 36 (ac5500es070522).