Aircommand HERON 2.2 Owner's Manual

Other manuals for HERON 2.2: Installation Instructions Manual

Summary of HERON 2.2

  • Page 1

    • installation instructions • commissioning of heron 2.2 after installation • possible faults and remedy • specifications • warranty conditions • notice d’installation • mise en service d’ibis après l’installation • défauts éventuels et solutions • spécifications • conditions de garantie • einbauanl...

  • Page 2

    Warranty of refrigerated airconditioning warranty within australia we undertake by this warranty to rectify, free of charge, at our nearest authorised service agent, any fault due to faulty workmanship or replacement of any faulty components within 12 months from the date of the first retail purchas...

  • Page 3

    Customer’s copy purchaser’s name ............................................................................................................................................................................................................................. Address ........................................

  • Page 4

    Installation instructions for heron 2.2 the heron 2.2 is suitable for installation in most caravans & motorhomes. Installation in commercial and industrial vehicles and equipment should be referred to aircommand aust for assessment of suitability. The heron system must be installed in accordance wit...

  • Page 5

    Installing the condenser set ■ marking out the floor use the floor template as provided (or refer to fig. 3). Both, or either end of the con/set may be hard against a wall or panel, but the back of the unit must have sufficient clearance to allow easy access to the line valves (see fig. 4). Once a c...

  • Page 6

    Pipe installation & control wiring the pipe work consists of a 1 / 4 ” tube (liquid line), and a 3 / 8 ” tube (return gas) running between the con/set and the a/h. The 3 / 8 ” line must be insulated with 10 x 10 mm foam rubber insulation. Connection is made at the side of the con/set. Pipe work may ...

  • Page 7

    Figure 8 minimum space required on lhs of air handler 4 mark out the a/h cut out as per fig. 7. Ensure the choice of location satisfies the following: a. The facia panel will be centrally located. B. The right hand edge of the cutout is a minimum of 50 mm from right hand end of the cupboard. This wi...

  • Page 8

    5 ■ now install the air handler insert the a/h into the front panel, and shift to the right as far as possible such that the right hand flange is fully over the front panel. Now insert a screw to hold the a/h in place while the copper tubes are manipulated to line up with the respective nipples. Mar...

  • Page 9

    Power supply the unit is designed to plug into a normal mains electricity supply. This plug must be accessible after installation. If a new plug is installed, then it must be positioned near to the airhandler and be easily accessible. Note: the supply cord is designated type f. If replacement is nec...

  • Page 10

    Leak testing it is of the utmost importance that a leak check is made on the 4 flare nut connections. A leak, however small, will result in the aircon system losing capacity and endanger the compressor. 1. Use either soapy water, or a proprietary leak test solution. Paint on each flare nut (particul...

  • Page 11

    Unit specifications condenser set: height - 250 mm above floor width - 465 mm depth - 440 mm weight - 30 kg air handler: height - 240 mm width - 385 mm depth - 250 mm weight - 4 kg minimum cupboard dimensions: 320 high x 525 wide x 340 deep cooling output: 2.2 kw heating output: 1.5 kw maximum curre...

  • Page 12

    9.

  • Page 13

    10 condenser set is noisy and vibrates “tipping” noise from con/set “tipping” noise from a/h unit does not energize a/h fan will not run on any speed compressor & cond. Fan will not run insufficient cooling insufficient heating water drips from a/h trouble shooting check that general pipework is not...

  • Page 14

    Please send to: aircommand australia pty ltd 954 port road, albert park south australia 5014 australia envoyer à: aircommand australia pty ltd 954 port road, albert park south australia 5014 australia bitte einschicken an: aircommand australia pty ltd 954 port road, albert park south australia 5014 ...

  • Page 15

    Manufacturer’s copy purchaser’s name ............................................................................................................................................................................................................................. Address ....................................

  • Page 16: Aircommand Australia Pty Ltd

    Aircommand australia pty ltd 954 port road, albert park south australia 5014 australia tel: (08) 8345 8444 fax: (08) 8243 0628 aircommand europe airva zi les béthunes 10, avenue du fief 95310 st ouen l aumone france tel: +33 (0) 134642333 pantone cool grey 9u pantone 301 u pantone ds196 - 4 u (alter...