Airfree FIT 800 Instruction Manual - page 4
4
Guide for Airfree
®
installation in mold contaminated rooms
1 - Install your Airfree
®
unit in accordance with the user manual
2 - Allow your unit to run for at least one week to achieve significant airborne mold spore reduction.
3 - Clean mold infected items and surfaces, since they are a continuous source of new spores.
It is important to stress that Airfree
®
will not destroy or remove mold from an infected item or surface. Those
surfaces must be cleaned manually.
Airfree
®
will destroy airbone molds, spores and prevents them from contaminating other areas, inhibiting the
growth of existing and new colonies.
Airfree
®
and Mold
Installing and Connecting
Plug power cord into the nearest outlet. Make sure the surface is dry (never place Airfree
®
on
wet floor or immerge it in water). Make sure side led light is on. Adjust the night light intensity
with the touch sensor. After 10 minutes the top lid should be warm.
Place Airfree
®
on a flat surface not exceeding 3’ cm from the floor, not under furniture, shelves,
or behind curtains as it will reduce airflow and Airfree
®
efficiency in reducing microorganisms.
Check if the area is compatible with the unit capacity to achieve best unit performance. Using
Airfree in rooms larger than its capacity will greatly reduce its purifying capacity.
Airfree
®
must be continuously on in the same room, 24 hours a day.
Airfree
®
can be installed in rooms equipped with air conditioning and heating systems.
However it is recommended not to place it nearby to avoid potential interference in Airfree
®
air flow.
Airfree
®
can be placed in corridors but the air sterilization effects will barely have any effect
in connecting rooms.
Airfree
®
shall not be placed near doors or under windows to avoid sterilized air to exit the
room.
Airfree
®
is to be used in rooms with minimum air volume of 330 ft
³
.
Drill 2 vertical holes spaced apart as per the attached diagram.
After drilling the 2 holes, install the enclosed 2 screws leaving 5mm free distance from the wall.
Hang Airfree
®
from the two screws. Make sure Airfree
®
can not be removed after installation
by exercising upward pressure. If loose, please remove Airfree
®
and gradually tighten the
screws until Airfree
®
is really secured to the wall.