AirLive SP-101 User Manual

Manual is about: Smart energy plug in

Summary of SP-101

  • Page 1

    Sp-101 smart energy plug in switch user manual.

  • Page 2: Copyright & Disclaimer

    Copyright and disclaimer i airlive sp-101 user manual copyright & disclaimer no part of this publication may be reproduced in any form or by any means, whether electronic, mechanical, photocopying, or recording without the written consent of ovislink corp. Ovislink corp. Has made the best effort to ...

  • Page 3

    Copyright and disclaimer airlive spi-101 user manual ii fcc interference statement this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interfe...

  • Page 4: Table Of Contents

    Table of contents airlive sp-101 user manual iii table of contents 1. Overview ................................................................................................... 1 1.1 adding to z-wavetm network ........................................................... 1 1.2 led indication ..........

  • Page 5: Overview

    1. Overview airlive sp-101 user manual 1 1 1. Overview this plug-in on/off switch is a security enabled wireless switch, based on z-wave plus technology. Z-wave plustm enabled devices displaying the z-wave plustm logo can also be used with it regardless of the manufacturer, and can also be used in o...

  • Page 6

    1. Overview airlive sp-101 user manual 2 1.1.1. Auto inclusion the function of auto inclusion will be executed as long as the switch does not have node id and just plug the switch into a wall outlet. Note: auto inclusion timeout is 2 minute during which the node information of explorer frame will be...

  • Page 7: 1.2 Led Indication

    1. Overview airlive sp-101 user manual 3 or if your controller requires to have the plug send a 'node information frame' or nif for associations, then pressing the on/off button three times within 2 seconds will cause the plug to send its nif. 2. There are only one group for the switch ※ including a...

  • Page 8: 1.5 Programming

    1. Overview airlive sp-101 user manual 4 2. Plug the load into the switch. Make sure the load to be controlled cannot exceed 13a. 3. Press the button or switch on the load to the on position. 4. To manually turn on the switch, press and release the on/off button. The led will turn on, and the load p...

  • Page 9

    1. Overview airlive sp-101 user manual 5 1.5.2.1. Auto report to grouping 1 (maximum node 1) 1.5.2.1.1. On/off event report when “on” or “off” state has been changed, it will send binary switch report to the node of grouping 1. Binary switch report on:[command class switch binary, switch binary repo...

  • Page 10

    1. Overview airlive sp-101 user manual 6 meter value 4 = 0xea (w) meter (w) = meter value 3 *256 + meter value 4 = 100.2w 1.5.2.2.2. Accumulated power consumption ( kw /h) when receiving meter get command, it will report meter report command to the node. Meter get command: [command class meter, mete...

  • Page 11

    1. Overview airlive sp-101 user manual 7 1.5.2.2.5. Ac load current (i) when receiving meter get command, it will report meter report command to the node. Meter get command: [command class meter, meter get, scale =0x05(i)] meter report command: [command class meter , meter report , rate type = 0x01 ...

  • Page 12

    1. Overview airlive sp-101 user manual 8 caution 5 restore switch state mode 1 0-2 1 0: switch off 1: last switch state 2 : switch on 6 mode of switch off function 1 0-1 1 1. : disable 2. : enable 7 led indication mode 1 1-3 1 1 : show switch state 2 : show night mode 3 : one flash mode 8 auto off t...

  • Page 13

    1. Overview airlive sp-101 user manual 9 1.5.3.6. Mode of switch off function: when the mode of switch on/off is set to 0, any command of switch off will be disabled and the on/off function of include button will be disabled. The default setting is enable mode. When manual on/off function is disable...

  • Page 14: 1.6 Troubleshooting

    1. Overview airlive sp-101 user manual 10 1.5.5. Firmware update over the air (ota) plug is based on 500 series soc and supports firmware update command class, it can receives the updated firmware image sent by controller via the z-wave rf media. It is a helpful and convenient way to improve some fu...

  • Page 15: 1.7 Specifications

    1. Overview airlive sp-101 user manual 11 1.7 specifications operating voltage 220v~240v / 50hz for eu type operating voltage 100v~120v / 50hz/60hz for us type maximum load (ampere) 13a (resistive load) socket type: germany type france type uk type us type range minimum 40 m in door 100m outdoor lin...