Airpax Dimensions 24/4500H-3PH Owner's Manual

Summary of 24/4500H-3PH

  • Page 1

    Iso 9001:2000 certified company dc to ac power inverters owners manual for models: 24/4500h-3ph 24/6000h-3ph form 120015 owners manual january 2007 120015c a irp ax d im e n s io n s , in c . 44 6 7 w h ite b e ar p a rk w a y (6 51 ) 65 3 -70 0 0 s t. P a u l, m n 55 1 1 0-7 62 6 f a x (65 1 ) 65 3...

  • Page 2

    Owners manual inverter model 24/4500h-3ph 24/6000h-3ph table of contents page 1. General . . . . . . . . . . . 2 2. Description . . . . . . . . 2 3. Installation . . . . . . . . 2 4. Start up/operation. . . 4 5. Troubleshooting. . . . . 4 6. Installation figure 1. . 5 7. Limited warranty . . . . 6 1...

  • Page 3

    Important note for vehicle installation: do not use the vehicle chassis as the negative return in place of a return cable. Use the same size cable as the positive connection and run directly to the battery. 3.05.5 install the cables at the battery, inverter and then fuse holder. Make sure that clean...

  • Page 4

    Page 4 circuit modified to accept +24 vdc instead of +12 vdc. The remote switch must be connected to the violet wire marked "remote switch hookup". 3.07 220y/120 vac output 3.07.1 caution: do not connect another source of ac power directly to the output of the inverter. This will result in damage to...

  • Page 5

    3 phase inverter figure 1 page 5 * +24 v for units with a model designation ending in "r24". Customer supplied on/off switch fuse 24 volt auxiliary battery pack + 12 vdc* ground l1 l3 neutral l2 + + violet wire output cir- cuit breaker running time meter battery voltage indicators on/off switch.

  • Page 6

    Limited warranty terms & conditions page 6 shipping terms: f.O.B. St. Paul minnesota. Freight prepaid and billed, subject to prior credit approval. Minimum order: $50.00 net price loss or damage: loss or damage in transit is the responsibility of the carrier. Any claim should be filed with the deliv...