Anritsu CMA 5000 - UTA Specifications

Manual is about: Universal Transport Analysis Module / SDH/SONET Application

Summary of CMA 5000 - UTA

  • Page 1

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 1 of 14 cma 5000 - uta specifications universal transport analysis module / sdh/sonet application content • the perfect tool for testing sdh & sonet core networks up to 10 gbps • testing aps switch time ...

  • Page 2

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 2 of 14 key features key applications •••• sdh/sonet interfaces up to 10 gbps •••• pluggable xfp & sfp – 1310 nm / 1550 nm •••• generates and analyzes sonet/sdh frames down to the tributary level (ds1/e1...

  • Page 3

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 3 of 14 testing aps switch time reaction of the network with 125 µs resolution due to the large amount of information being transferred over synchronous optical network (sonet/sdh), it is extremely impor...

  • Page 4

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 4 of 14 auto-discovery of the signal structure when performing tests in the field, it is sometimes difficult to configure the test equipment as the signal to be analyzed is not always known: is the signa...

  • Page 5

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 5 of 14 fast and professional reports creating professional report has never been so easy with the uta application. After stopping a measurement, the report is just one click away: produce, save, print r...

  • Page 6: Specifications

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 6 of 14 specifications notes 1 the xfp/sfp interfaces of the uta module meet the requirements stated in the msa standard 2 requires xfp/sfp that must be ordered separately (see the ordering guide) interf...

  • Page 7

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 7 of 14 dcc signals the uta-sdh/sonet application supports the drop and insert of dcc channels from sonet/sdh • d1-d3: 192 kb/s • d4-d12: 576 kb/s sonet mappings.

  • Page 8

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 8 of 14 sdh mappings test pattern prbs patterns • prbs: 2 9 -1, 2 11 -1, 2 15 -1, 2 20 -1, qrss, 2 23 -1, 2 29 -1, 2 31 -1 inverted and non-inverted word patterns • all “1” pattern, all “0” pattern, alte...

  • Page 9

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 9 of 14 error addition sonet/dsn • a1/a2, b1, b2, rei-l, b3, rei-p, v5, rei-v, faw (fas), sfaw, fps, maw, parity p, parity cp, f-bit, m-bit, febe, crc-6, prbs, word, transmission errors sdh/pdh • a1/a2, ...

  • Page 10

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 10 of 14 alarm addition sonet/dsn • los, lof, sef, tim-s, ais-l, rdi-l, ais-p, lop-p, tim-p, plm-p, uneq-p, rdi-p, lom-v, ais-v, lop-v, plm-v, uneq-v, rdi-v, tim-v, rfi-v, lomf, lsf, oof, rai, idle, lss,...

  • Page 11

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 11 of 14 path analysis signal qualification • power meter • frequency meter errors analysis • sonet/dsn a1/a2, b1, b2, rei-l, b3, rei-p, v5, rei-v, faw (fas), sfaw, fps, maw, parity p, parity cp, f-bit, ...

  • Page 12

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 12 of 14 performance analysis • direct graphical presentation of performance and availability conformance test result • automatic calculation of acceptance thresholds according to itu-t recommandations, ...

  • Page 13: Ordering Information

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 13 of 14 ordering information note 1: for best performance, the cma5000 platform must have 512m ram when using uta with more than one application. Note 2: all the 10g/11g applications are field upgradeab...

  • Page 14

    Iso 9001:2000 certified. Icma5kutastm64-spec05-0806-a4. ©2008 anritsu. All rights reserved. Page 14 of 14 anritsu corporation 5-1-1 onna, atsugi-shi, kanagawa, 243-8555 japan phone: +81-46-223-1111 fax: +81-46-296-1264 • u.S.A. Anritsu company 1155 east collins blvd., richardson, tx 75081, u.S.A. To...