Anritsu MN469xC Series Installation Manual

Manual is about: Multiport Test Set

Summary of MN469xC Series

  • Page 1

    Installation guide vectorstar ™ mn469xc series multiport test set vectorstar mn4694c, k connectors, for the ms4642a/b or ms4644a/b vna vectorstar mn4697c, v connectors, for the ms4645a/b or ms4647a/b vna anritsu company 490 jarvis drive morgan hill, ca 95037-2809 usa http://www.Anritsu.Com part numb...

  • Page 3: Table of Contents

    Mn469xc multiport test set ig pn: 10410-00737 rev. C contents-1 table of contents chapter 1—general information 1-1 introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-2 test set description . . . . . . . ...

  • Page 4

    Contents-2 pn: 10410-00737 rev. C mn469xc multiport test set ig table of contents (continued) 4-7 preparation for shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 use a suitable container. . . . . . . . . . . . . . . . . . . . . ....

  • Page 5

    Mn469xc multiport test set ig pn: 10410-00737 rev. C 1-1 chapter 1 — general information 1-1 introduction this manual provides general information, installation, operating, and maintenance information for the vectorstar mn469xc series multiport test sets. The following model multiport test sets are ...

  • Page 6

    1-3 test set components general information 1-2 pn: 10410-00737 rev. C mn469xc multiport test set ig 1-3 test set components the mn469xc series multiport test set comes with the following components. Table 1-1. Mn469xc multiport test set components and cables part numbers description connection from...

  • Page 7

    General information 1-4 functional description mn469xc multiport test set ig pn: 10410-00737 rev. C 1-3 1-4 functional description the functional description is based on the functional block diagram of the mn469xc series test set shown below ( figure 1-2 ). The vectorstar vna sends switch control co...

  • Page 8

    1-5 technical specifications general information 1-4 pn: 10410-00737 rev. C mn469xc multiport test set ig 1-5 technical specifications for complete technical specifications, refer to the vectorstar mn469xc series multiport technical data sheet – 11410-00777. 1-6 related documentation all documents l...

  • Page 9

    General information 1-7 contacting anritsu mn469xc multiport test set ig pn: 10410-00737 rev. C 1-5 vectorstar mn469xc series multiport vna measurement system • mn469xc series multiport vna measurement system technical data sheet – 11410-00777 • mn469xc series multiport test set installation guide –...

  • Page 10

    1-7 contacting anritsu general information 1-6 pn: 10410-00737 rev. C mn469xc multiport test set ig.

  • Page 11

    Mn469xc multiport test set ig pn: 10410-00737 rev. C 2-1 chapter 2 — hardware installation 2-1 introduction this chapter provides installation instructions for the multiport test set. It includes information on initial inspection, preparation for use, front and rear panel connections, and general pu...

  • Page 12

    2-5 system connections hardware installation 2-2 pn: 10410-00737 rev. C mn469xc multiport test set ig 2-5 system connections the figure below shows the front panel connections between the test set and vna. Make the semi-rigid cable connections as shown in figure 2-1 , figure 2-2 , and in table 2-1 ....

  • Page 13

    Hardware installation 2-5 system connections mn469xc multiport test set ig pn: 10410-00737 rev. C 2-3 rear panel connections 1. Connect the gpib cable between the vna rear panel dedicated gpib connector and the test set ieee 488.2 gpib connector as shown in figure 2-2 . 2. On the vna rear panel, rem...

  • Page 14

    2-5 system connections hardware installation 2-4 pn: 10410-00737 rev. C mn469xc multiport test set ig table 2-1. Mn469xc multiport semi-rigid cable interconnect part numbers and locations index part numbers description/torque connection from connection to front panel connections 1 3-62109-42 v (m-m)...

  • Page 15

    Hardware installation 2-5 system connections mn469xc multiport test set ig pn: 10410-00737 rev. C 2-5 8 3-62112-81 sma male-male semi-rigid tighten using an 8 mm (5/16 in) torque end wrench set to 0.9 n·m (8 lbf·in). Ms464xb port labeled: p1 source loop out mn469xc port labeled: to vna port 1 src ou...

  • Page 16

    2-6 rear panel dip switch gpib address setting hardware installation 2-6 pn: 10410-00737 rev. C mn469xc multiport test set ig 2-6 rear panel dip switch gpib address setting the mn469xc series test set gpib address must match the gpib address set on the vna and is set on the test set by rear panel di...

  • Page 17

    Hardware installation 2-6 rear panel dip switch gpib address setting mn469xc multiport test set ig pn: 10410-00737 rev. C 2-7 changing vna addresses for the test set the default vna gpib address for the mn469xc series test set is gpib 16 and must match the address set on the test set through the rea...

  • Page 18

    2-7 power up sequence hardware installation 2-8 pn: 10410-00737 rev. C mn469xc multiport test set ig 2-7 power up sequence procedure 1. Make sure all of the cables are properly installed as illustrated in the previous sections. 2. Turn on the test set prior to launching the vna application on the vn...

  • Page 19

    Mn469xc multiport test set ig pn: 10410-00737 rev. C 3-1 chapter 3 — initial system checkout 3-1 introduction this chapter provides the general initial system checkout for a completely assembled multiport system. Once this procedure is complete, the system is ready for calibration and available to m...

  • Page 20

    3-3 mn469xc multiport test set configuration verification initial system checkout 3-2 pn: 10410-00737 rev. C mn469xc multiport test set ig 7. Select trace 3 and repeat step 3 setting numerator = b1, denominator = 1, driver port = 1. 8. Select trace 4 and repeat step 3, setting numerator = a2, denomi...

  • Page 21

    Initial system checkout 3-3 mn469xc multiport test set configuration verification mn469xc multiport test set ig pn: 10410-00737 rev. C 3-3 13. Select trace 4 and repeat step 8,, setting numerator = a4, denominator = 1, driver port = 4, reference position = 8. 14. Connect shorts to ports 3 and 4 on t...

  • Page 22

    3-3 mn469xc multiport test set configuration verification initial system checkout 3-4 pn: 10410-00737 rev. C mn469xc multiport test set ig.

  • Page 23: Maintenance

    Mn469xc multiport test set ig pn: 10410-00737 rev. C 4-1 chapter 4 — troubleshooting and maintenance 4-1 introduction this section provides the information necessary for maintenance of the multiport test set. Operator maintenance is limited to troubleshooting and repairs that can be made without rem...

  • Page 24

    4-3 troubleshooting gpib addresses troubleshooting and maintenance 4-2 pn: 10410-00737 rev. C mn469xc multiport test set ig figure 4-1. Remote inter. (remote interface) menu for gpib addresses.

  • Page 25

    Troubleshooting and maintenance 4-4 troubleshooting power up failure mn469xc multiport test set ig pn: 10410-00737 rev. C 4-3 4-4 troubleshooting power up failure troubleshooting by the operator consists of determining the cause of test set power up failure. The procedure below provides the necessar...

  • Page 26

    4-5 checking/changing the rear panel fuse troubleshooting and maintenance 4-4 pn: 10410-00737 rev. C mn469xc multiport test set ig 4-5 checking/changing the rear panel fuse the value of the line fuse used in the test set is printed on the rear panel next to the line voltage module. Procedure replace...

  • Page 27

    Troubleshooting and maintenance 4-6 preparation for storage mn469xc multiport test set ig pn: 10410-00737 rev. C 4-5 4-6 preparation for storage preparing the test set for storage consists of cleaning the unit, packing the inside with moisture-absorbing desiccant crystals, and storing the unit in a ...

  • Page 28

    4-7 preparation for shipment troubleshooting and maintenance 4-6 pn: 10410-00737 rev. C mn469xc multiport test set ig.

  • Page 29: Subject Index

    Symbols to p mn469xc multiport test set ig pn: 10410-00737 rev. C index-1 subject index symbols "l" rear panel dip switch . . . . . . . . . . . . . . . . . 2-6 "s" rear panel dip switch . . . . . . . . . . . . . . . . . 2-6 "t" rear panel dip switch . . . . . . . . . . . . . . . . . 2-6 numerics 100...

  • Page 30

    R to w index-2 pn: 10410-00737 rev. C mn469xc multiport test set ig r rear panel connectors and ports . . . . . . . . . . . . . . . . . . . 1-1 power cord . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 reference position . . . . . . . . . . . . . . . . . . . . . . . . 3-1 related document...

  • Page 32