Anritsu MS2830A-040 Product Brochure

Manual is about: Signal Analyzer: 9 kHz to 3.6 GHz; 9 kHz to 6 GHz; 9 kHz to 13.5 GHz; 9 kHz to 26.5 GHz; 9 kHz to 43 GHz

Summary of MS2830A-040

  • Page 1

    Ms2830a signal analyzer ms2830a-040: 9 khz to 3.6 ghz ms2830a-041: 9 khz to 6 ghz ms2830a-043: 9 khz to 13.5 ghz ms2830a-044: 9 khz to 26.5 ghz ∗ ms2830a-045: 9 khz to 43 ghz ∗ ∗ : see catalog for ms2830a-044/045. Product brochure.

  • Page 2

    The ms2830a is a high-speed, high-performance, cost-effective spectrum analyzer/signal analyzer. Not only can it capture wideband signals but fft technology supports multifunction signal analyses in both the time and frequency domains. Behavior in the time domain that cannot be handled by a sweep ty...

  • Page 3: Key Features

    Key features basic performance/functions ■ frequency range ms2830a-040: 9 khz to 3.6 ghz ms2830a-041: 9 khz to 6.0 ghz ms2830a-043: 9 khz to 13.5 ghz ■ total level accuracy: ±0.3 db (typ.) the absolute amplitude accuracy specification described in catalogs of other spectrum analyzers ignores the imp...

  • Page 4: Panel Layout

    Panel layout remote lamp lights up when the ms2830a is in a remote control state. Preset key resets parameters to their initial settings. Function keys used for selecting or executing function menu displayed on the right of the screen. The function menu contents are provided in multiple pages and la...

  • Page 5

    Ac inlet used for supplying power. Usb connectors (type a) used to connect a usb keyboard or mouse or the usb memory supplied with the ms2830a. Usb connector (type b) used when controlling the ms2830a externally via usb. Lan (ethernet) connector used for connecting to a personal computer or for ethe...

  • Page 6: Basic Performance

    Excellent total level accuracy: ±0.3 db (typ.) (common to both spectrum analyzer and signal analyzer performances) with a level calibration over a wide frequency range, the ms2830a has excellent total level accuracy. The absolute amplitude accuracy specification described in catalogs of other spectr...

  • Page 7: Basic Performance

    The measuring instrument level error cannot be said to really meet the specifications if measurement requires addition of a margin to the product test specification. Since specifications with added margin are severe, even genuinely passing products may sometimes be evaluated as failing due to this m...

  • Page 8: Basic Performance

    Wide dynamic range dynamic range is a key specification for spectrum analyzers. Low displayed average noise level (danl) as well as high toi are important too. Low toi may cause distortion with high-level carrier signals. Inserting an attenuator can lower the carrier level but this has the effect of...

  • Page 9: Basic Performance

    Improved level linearity conventional spectrum analyzers use an analog if and log amp to achieve good level accuracy at points near the log scale reference level, but the accuracy degrades at points that are further away. The ms2830a uses a digital if instead of a log amp, which supports measurement...

  • Page 10: Basic Performance

    Low consumption power, excellent eco product the ms2830a meets anritsu “excellent eco products” standard for environment-friendly products. It cuts consumed power by 50% compared to conventional models. Power consumption: ≤350 va (including all options) 110 va (nominal, with opt. 040, 3.6 ghz ∗ 1 ) ...

  • Page 11

    Wide dynamic range ∗ 1: requires opt. 006. ∗ 2: requires opt. 005 and opt. 006. ∗ 3: requires opt. 005, opt. 006 and opt. 077. ∗ 4: 300 khz ≤ f ∗ 5: excluding guard band. Signal analyzer: basic performance/functions wide bandwidth × high accuracy fft analysis opt. 006: 10 mhz max. (20 mhz max. Sampl...

  • Page 12

    Save signals in internal memory max. Capture time: 0.5 s to 2000 s max. Number of samples: 100 msamples the “analysis bandwidth × analysis time” signal is held in internal memory and saved to hard disk. Up to 100 msamples of data can be saved to memory for one measurement. The frequency span determi...

  • Page 13: Signal Analyzer: Trace

    Spectrum the spectrum trace displays a graph with amplitude on the y-axis and frequency on the x-axis. The captured iq data is fft processed (fast fourier transformed) and converted from the time domain to the frequency domain for display as a spectrum. Frequency vs. Time the frequency vs. Time trac...

  • Page 14: Signal Analyzer: Trace

    Spectrogram the spectrogram trace displays the level as color with frequency on the y-axis and time on the x-axis. The captured iq data is fft processed to confirm time variations in the continuous spectrum. It is useful for monitoring frequency hopping and transient signals. Measurement with sub-tr...

  • Page 15: Signal Analyzer: Trace

    Example: sub-trace display confirm analysis range in sub-trace, and target signal status on main trace. ↑ analysis range ↑ analysis range ↑ analysis range ↑ analysis range signal analyzer: trace product brochure l ms2830a 15.

  • Page 16

    Captured waveforms analysis using commercial analysis tools other digitizers may exhibit severe degradation of the rf channel during capture, requiring troublesome calibration of the captured data when using analysis tools. The ms2830a uses high-performance rf and two built-in calibration oscillator...

  • Page 17: Versatile Built-In Functions

    Useful for tx characteristics evaluation the ms2830a is fully loaded with all the functions required for evaluating tx characteristics. Tests can be performed simply and in accordance with standards using functions tailored to measurement contents. Measure function spa ∗ 1 vsa ∗ 2 channel power occu...

  • Page 18: Versatile Built-In Functions

    Example: spurious emission the japanese radio law governing measurement of spurious specifies searching for the peak level in the swept frequency segment using different parameter settings and then performing zero-span measurement of the found peak point. The ms2830a spurious measurement function no...

  • Page 19: Versatile Built-In Functions

    Measurement results ■ +peak, –peak, (peak-peak)/2, average measurement results ■ marker point frequency ■ marker point power ■ absolute power per hz in marker bandwidth ■ total power in marker bandwidth ■ difference between any markers measurement results ■ +peak, –peak, (peak-peak)/2, average measu...

  • Page 20: Versatile Built-In Functions

    2-tone 3rd-order intermodulation distortion by inputting two different frequency cw signals (desired waves), two-tone third-order intermodulation distortion is generated close to the desired waves according to non-linear characteristics of device under test (dut). Then, third order intercept (toi) i...

  • Page 21: Versatile Built-In Functions

    Versatile built-in functions phase noise (opt. 010) this function measures phase noise in the 10 hz to 10 mhz frequency offset range. Measurement results ■ carrier level ■ error between set frequency and carrier frequency ■ marker point phase noise level 10 hz 10 mhz offset basic performance upgrade...

  • Page 22: Versatile Built-In Functions

    Versatile built-in functions noise source supports noise sources from noisecom nc346 series. Nc346 series models and summary specifications are listed below. See the nc346 series catalog and datasheet for detailed specifications. K261 dc block return loss recommended dc blocks / adaptor combinations...

  • Page 23

    The ms2830a-020/021 vector signal generator covers the frequency range from 250 khz to 3.6 ghz/6.0 ghz; it has a wide vector modulation bandwidth of 120 mhz as well as a large built-in memory for storing 64 msamples/256 msamples (with opt. 027). Its level accuracy is at least as good as a dedicated ...

  • Page 24

    Versatile multiple waveform generation any type of waveform can be generated using the ms2830a-020/021 signal generator option. In addition to using c and simulation tools, anritsu's iqproducer can be run on a pc to edit waveform parameters and output waveforms. Wanted signal awgn wanted signal + aw...

  • Page 25

    Useful iqproducer waveform generation software iqproducer is application software for a pc for editing, creating and transferring waveform patterns using the ms2830a-020/021 arbitrary waveform generation option. It has the following three main functions. • parameter editing: function for easily edit...

  • Page 26

    Ber measurement function (opt. 026): basic performance convenient built-in ber measurement function for rx evaluations the ms2830a with the opt. 026 ber measurement function supports measurement up to 10 mbps. It supports rx sensitivity tests by inputting the receiver-demodulated data/clock/enable t...

  • Page 27

    Excellent expandability platform (hardware) the versatility of the ms2830a series is tailored easily to the application by installing modules in expansion slots. Basic function and performance upgrades ms2830a-001/101 rubidium reference oscillator/retrofit this option is a 10 mhz reference crystal o...

  • Page 28

    Expansion functions ms2830a-010/110 phase noise measurement function/retrofit phase noise measurements frequency range: 10 mhz to main-frame upper limit frequency offset frequency range: 10 hz to 10 mhz ms2830a-017/117 noise figure measurement function/retrofit adds noise figure measurement function...

  • Page 29

    Future-proof platform (software ∗ ) adding measurement software options to the signal analyzer assures that the modulation analysis and other functions will support all common current and future communications systems. Measurement software communications systems model name addition to main frame (:...

  • Page 30

    Adding a license for the iqproducer waveform generation software to the vector signal generator option supports easy generation of test patterns for all common communications systems worldwide. Iqproducer license for ms2830a-020/021 vsg following licenses (option) are required to download waveform p...

  • Page 31: Specifications

    Specifications the specification is the value after 30-minute warm-up at a constant ambient temperature. The specifications are defined under the following conditions unless otherwise specified. Auto sweep time select: normal, auto sweep type rules: sweep only, switching speed mode: best phase noise...

  • Page 32

    ■ signal analyzer/spectrum analyzer (continuation) reference level setting range log scale: –120 to +50 dbm, or equivalent level linear scale: 22.4 μv to 70.7 v, or equivalent level setting resolution: 0.01 db, or equivalent level scale units log scale: dbm, dbμv, dbmv, dbμv (emf), dbμv/m, v, w line...

  • Page 33

    ■ signal analyzer/spectrum analyzer (continuation) connector rf input connector: n-j (front panel), 50Ω (nominal) 18° to 28°c, input attenuator: ≥10 db vswr (nominal): ≤1.2 (40 mhz ≤ f ≤ 3 ghz) ≤1.5 (3 ghz ≤1.6 (6 ghz external reference input connector: bnc-j (rear panel), 50Ω (nominal) frequency: 5...

  • Page 34

    ■ spectrum analyzer frequency span range: 0 hz, 300 hz to 3.6 ghz [ms2830a-040] 0 hz, 300 hz to 6 ghz [ms2830a-041] 0 hz, 300 hz to 13.5 ghz [ms2830a-043] resolution: 2 hz accuracy: ±0.2% (sweep points: 10001) frequency readout accuracy ±(display frequency × frequency reference accuracy + span frequ...

  • Page 35

    ■ spectrum analyzer (continuation) spurious responses 2-tone 3rd-order intermodulation distortion 18° to 28°c, ≥300 khz separation without ms2830a-008, or preamp: off mixer input level: –15 dbm (1wave) ≤–54 dbc, toi = +12 dbm (30 mhz ≤ f ≤–60 dbc, toi = +15 dbm (300 mhz ≤ f ≤–58 dbc, toi = +14 dbm (...

  • Page 36

    ■ signal analyzer display waveform data, such as spectrum, power vs. Time captured at specific time general trace mode spectrum, power vs. Time, frequency vs. Time, phase vs. Time, ccdf, spectrogram, no trace analysis bandwidth sets capture analysis bandwidth from center frequency 1 khz to 10 mhz (1...

  • Page 37

    ■ signal analyzer (continuation) spectrum displayed function function outline displayed spectrum of any time length and frequency range within captured waveform data analysis time length analysis start time: sets analysis start time point from waveform data header analysis time length: sets analysis...

  • Page 38

    ■ signal analyzer (continuation) power vs. Time displayed function function outline displayed time changes of power for captured waveform data analysis time range analysis start time: sets analysis start time position from beginning of waveform data analysis time length: sets analysis time length se...

  • Page 39

    ■ signal analyzer (continuation) replay function function outline captured waveforms can be replayed again by using the vsa function to read saved digitize data conditions for measurable waveform data format: i, q (binary format) combination of span, sampling rate, and minimum capture sample span sa...

  • Page 40

    ■ ms2830a-020 3.6 ghz vector signal generator/ms2830a-021 6 ghz vector signal generator ∗ : use the ms2830a-021 for frequencies higher than 3.6 ghz. The specifications of the ms2830a-020/021 are defined under the following conditions unless otherwise specified. Cw pulse modulation: off modulation af...

  • Page 41

    ■ ms2830a-020 3.6 ghz vector signal generator / ms2830a-021 6 ghz vector signal generator (continuation) signal purity harmonic spurious output level: ≤0 dbm (without ms2830a-022), ≤–5 dbm (with ms2830a-022), cw non-harmonic spurious offset from output frequency: ≥15 khz output level: ≤0 dbm (withou...

  • Page 42

    ■ ms2830a-026 ber measurement function connector aux connector(rear panel) ∗ ∗ : can convert to bnc by connecting aux conversion adapter (j1556a). Input level ttl level input signal data, clock, enable input bit rate 100 bps to 10 mbps measured patterns pn9, pn11, pn15, pn20, pn23, all0, all1, alter...

  • Page 43

    ■ ms2830a-066 low phase noise performance signal analyzer/spectrum analyzer frequency range 9 khz to 3.7 ghz 9 khz to 3.5 ghz (frequency band mode: spurious) span 300 hz to 1 mhz (spectrum analyzer) 1 khz to 31.25 mhz (signal analyzer) ssb phase noise 18° to 28°c 500 mhz, spectrum analyzer, switchin...

  • Page 44

    ■ ms2830a-077 analysis bandwidth extension to 62.5 mhz (requires ms2830a-005 and ms2830a-006) ms2830a-078 analysis bandwidth extension to 125 mhz (requires ms2830a-005, ms2830a-006 and ms2830a-077) an image response is received when setting the bandwidth to more than 31.25 mhz. This can be used when...

  • Page 45

    ■ ms2830a-077 analysis bandwidth extension to 62.5 mhz (requires ms2830a-005 and ms2830a-006) ms2830a-078 analysis bandwidth extension to 125 mhz (requires ms2830a-005, ms2830a-006 and ms2830a-077) (continuation) amplitude displayed average noise level (danl) 18° to 28°c, input attenuator: 0 db with...

  • Page 46: Options Configuration Guide

    Options configuration guide options configuration refer two table shown below about the hardware / software which each frequency model of ms2830a can implement. Hardware frequency range (ms2830a-040/041/043/044/045) not upgradable. = can be installed, no = cannot be installed, r = require, u = upgra...

  • Page 47

    Software = can be installed, no = cannot be installed, r = require, u = upgrade model name addition to main frame analysis bandwidth note 040 041 043 044 045 005 006 009 077 078 mx269010a mobile wimax measurement software no r r no mx269011a w-cdma/hspa downlink measurement software  r mx269012a w-...

  • Page 48: Ordering Information

    Model/order no name ms2830a – main frame – signal analyzer p0031a z0541a – standard accessories – power cord: 1 pc usb memory (≥256 mb, usb2.0 flash driver): 1 pc usb mouse: 1 pc install cd-rom (application software, instruction manual cd-rom): 1 pc ms2830a-040 ms2830a-041 ms2830a-043 – options – 3....

  • Page 49

    Model/order no name w3334ae w2851ae w3335ae w2853ae w3336ae w2855ae w3117ae w3118ae w3655ae w3656ae w3337ae w3338ae w2914ae w2929ae – application parts – following operation manuals provided as hard copy ms2830a operation manual (mainframe operation) ms2690a/ms2691a/ms2692a and ms2830a operation man...

  • Page 50

    J1556a aux conversion adapter b0671a front cover for 1mw4u ms2830a with front cover ma24106a usb power sensor b0636c carrying case (hard type, with casters) b0645a soft carrying case 50 product brochure l ms2830a.

  • Page 51: Note:

    Note: product brochure l ms2830a 51.

  • Page 52

    X 8qlwhg6wdwhv $qulwvx&rpsdq\ (dvw&roolqv%oyg6xlwh5lfkdugvrq 7;86$ 7roo)uhh 3krqh )d[ x &dqdgd $qulwvx(ohfwurqlfv/wg 6loyhu6hyhq5rdg6xlwh.Dqdwd 2qwdulr.9&&dqdgd 3krqh )d[ x %ud]lo $qulwvx(ohwu{qlfd/wgd 3udod$pdghx$pdudo$qgdu %hod9lvwd6mr3dxor63%ud]lo 3krqh )d[ x 0h[lfr $qulwvx&rpsdq\6$gh&9 $y(mpuflw...