Anritsu MT8852B Remote Programming Manual

Other manuals for MT8852B: Operation Manual
Manual is about: Bluetooth Test Set

Summary of MT8852B

  • Page 1

    ® mt8852b remote programming manual bluetooth test set.

  • Page 2: Remote Programming Manual

    Remote programming manual mt8852b bluetooth test set p/n: 13000-00110 revision: v printed: february 2017 copyright 2017 anritsu company.

  • Page 3: Warranty

    Warranty the anritsu corporation will repair this equipment free-of-charge if a malfunction occurs within one year after shipment due to a manufacturing fault. However, software fixes will be made in accordance with the separate software end-user license agreement. Moreover, anritsu corporation will...

  • Page 4

    Software end-user license agreement (eula) please read this software end-user license agreement (hereafter this eula) carefully before using (includes executing, copying, registering, etc.) this software (includes programs, databases, scenarios, etc., used to operate, set, etc., anritsu electronic e...

  • Page 5

    4. Export restrictions you may not use or otherwise export or re-export directly or indirectly this software except as authorized by japanese and united states law. In particular, this software may not be exported or re-exported (a) into any japanese or us embargoed countries or (b) to anyone on the...

  • Page 6: Ce Conformity Marking

    Ce conformity marking anritsu affixes the ce conformity marking onto its conforming products in accordance with council directives of the council of the european communities in order to indicate that these products conform to the emc and lvd directive of the european union (eu). Rcm conformity marki...

  • Page 7

    Vxworks runtime license 2000-1189 windml target license 2000-1372 ni device license 3-2000-1486 windriver usb runtime license 2000-1421.

  • Page 8

    Signal generator mode and cw measurement 9-6 pn: 13000-00110 rev. V mt8852b programming manual edr signal generator mode (mt8852b and mt8852b-042 only) use this command to generate enhanced data rate (edr) modulation schemes. Set command format esiggen pi4

  • Page 10: Safety Symbols

    Mt8852b programming manual pn: 13000-00110 rev. V safety-1 safety symbols to prevent the risk of personal injury or loss related to equipment malfunction, anritsu company uses the following symbols to indicate safety-related information. For your own safety, please read the information carefully bef...

  • Page 11: For Safety

    Safety-2 pn: 13000-00110 rev. V mt8852b programming manual for safety warning always refer to the operation manual when working near locations at which the alert mark, shown on the left, is attached. If the operation, etc., is performed without heeding the advice in the operation manual, there is a ...

  • Page 12: Table of Contents

    Mt8852b programming manual pn: 13000-00110 rev. V contents-1 table of contents chapter 1—general information 1-1 about this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 comments on this manual. . . . . . . . . . . . . . . . . . . . . . ...

  • Page 13

    Contents-2 pn: 13000-00110 rev. V mt8852b programming manual *leetf (ble eut fail register query) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 *opc (operation completed indication) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 *rst (instrument reset) . . . . . . . . ...

  • Page 14: Chapter 7—Sco Connections

    Mt8852b programming manual pn: 13000-00110 rev. V contents-3 eutrs232 (eut rs232 hci set up). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16 eutsrce (eut address source) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18 hwinfo (hardware information) . . . . . . . ....

  • Page 15

    Contents-4 pn: 13000-00110 rev. V mt8852b programming manual differential phase encoding test configuration (edpcfg) . . . . . . . . . . . . 10-26 edr sensitivity test configuration (ebscfg) . . . . . . . . . . . . . . . . . . . . . . 10-28 edr ber floor sensitivity test configuration (efscfg) . . ....

  • Page 16

    Mt8852b programming manual pn: 13000-00110 rev. V contents-5 tstctrl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-25 ttbitcnt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-26 txpwr . . ...

  • Page 17: Chapter 16—Ble Measurement

    Contents-6 pn: 13000-00110 rev. V mt8852b programming manual multi slot sensitivity test results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-25 maximum input power test results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-26 15-6 edr tests. . . . . . . . . . ...

  • Page 18

    Mt8852b programming manual pn: 13000-00110 rev. V contents-7 pathrd (read a complete path loss table) . . . . . . . . . . . . . . . . . . . . . . 17-11 pathtbl (set path offset table). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-12 pathtblclr (clear a user path table) . . . . . ...

  • Page 19

    Contents-8 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 20: 1-1

    Mt8852b programming manual pn: 13000-00110 rev. V 1-1 chapter 1 — general information 1-1 about this manual this manual provides instructions on the remote operation of the following model types: • mt8852b bluetooth test set (with edr and audio) • mt8852b-040 bluetooth test set (without edr or audio...

  • Page 21: Associated Documentation

    About this manual general information 1-2 pn: 13000-00110 rev. V mt8852b programming manual notification of software release the mt8852b software is periodically updated as new features are added to meet market demands. To receive automatic notification of software releases, send a blank e-mail with...

  • Page 22: 1-2

    General information command format mt8852b programming manual pn: 13000-00110 rev. V 1-3 1-2 command format the commands are presented in a structured manner as shown below. Set command format for each command, the command name and syntax are detailed. For example: command[,,] each of the allowable ...

  • Page 23

    Command format general information 1-4 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 24: 2-1

    Mt8852b programming manual pn: 13000-00110 rev. V 2-1 chapter 2 — gpib overview the mt8852b bluetooth test set can be operated remotely through a general purpose interface bus (gpib) connection to a host computer. The mt8852b conforms to the ieee488.1 and ieee488.2 standards. 2-1 requirements when u...

  • Page 25: 2-3

    Termination gpib overview 2-2 pn: 13000-00110 rev. V mt8852b programming manual 2-3 termination all commands sent over the gpib interface to the mt8852b must be terminated with either (or both) of the following: end of string (eos): the ‘’ or 0x0a character. End of message indicator (eoi): a hardw...

  • Page 26: 2-5

    Gpib overview gpib 488.2 registers mt8852b programming manual pn: 13000-00110 rev. V 2-3 2-5 gpib 488.2 registers the following diagram shows the gpib event and status registers. The meaning of each bit is described below. Status byte register and service request enable register figure 2-1. Status b...

  • Page 27

    Gpib 488.2 registers gpib overview 2-4 pn: 13000-00110 rev. V mt8852b programming manual table 2-4. Esb (event status bit) when a bit is set in the event register and the corresponding bit has been set in the event status enable register (ese) the esb bit in the status register is set. Mav (message ...

  • Page 28

    Gpib overview gpib 488.2 registers mt8852b programming manual pn: 13000-00110 rev. V 2-5 standard event status register and standard event status enable register figure 2-2. Standard event status and standard event status enable registers table 2-5. Esr and ese bit definitions pon power on bit. This...

  • Page 29

    Gpib 488.2 registers gpib overview 2-6 pn: 13000-00110 rev. V mt8852b programming manual eut fail register and fail enable register this eut register is cleared on the start of a test or script. When a test completes, if it has failed the test limit parameters enabled to give a fail result the corre...

  • Page 30

    Gpib overview gpib 488.2 registers mt8852b programming manual pn: 13000-00110 rev. V 2-7 instrument status register and instrument status enable register the ins register displays the present status of the instrument and can be used to provide srqs for test or script completion and the connection st...

  • Page 31

    Gpib 488.2 registers gpib overview 2-8 pn: 13000-00110 rev. V mt8852b programming manual change register and change enable register the chg register indicates when a change of state has occurred in the instrument, and can be used to provide srqs by setting the corresponding bits in the che register....

  • Page 32: Mt8852B-042 Only)

    Gpib overview gpib 488.2 registers mt8852b programming manual pn: 13000-00110 rev. V 2-9 edr eut fail register and edr eut fail enable register (mt8852b and mt8852b-042 only) the edr eetf test fail register is cleared at the start of a test or script. If an edr test fails any of the test limits appl...

  • Page 33: (Mt8852B-043 and

    Gpib 488.2 registers gpib overview 2-10 pn: 13000-00110 rev. V mt8852b programming manual ble eut fail register and ble eut fail enable register (mt8852b-043 and units with option 27 only) the ble leetf test fail register is cleared at the start of a test or script. If a ble test fails any of the te...

  • Page 34: 2-6

    Gpib overview gpib over rs232 mt8852b programming manual pn: 13000-00110 rev. V 2-11 2-6 gpib over rs232 version 1.1 or above of the control software supports the use of rs232 in addition to gpib commands. Use the rs232 connector on the rear panel of the unit. Hardware handshake cts and rts lines ar...

  • Page 35: 2-7

    Summary of rs232 commands gpib overview 2-12 pn: 13000-00110 rev. V mt8852b programming manual 2-7 summary of rs232 commands table 2-12. Mnemonic definitions mnemonic meaning comments !Dcl device clear clear all queues and terminates any pending actions. !Spl serial poll clears srq cause and returns...

  • Page 36: And Register Commands

    Mt8852b programming manual pn: 13000-00110 rev. V 3-1 chapter 3 — ieee 488.2 mandatory and register commands this chapter provides details of the event register and mandatory commands. The commands are listed in alphabetical order as shown below. *che (change enable register) the bits in the change ...

  • Page 37

    Ieee 488.2 mandatory and register commands 3-2 pn: 13000-00110 rev. V mt8852b programming manual *cls (clear gpib status bytes) *eete (edr eut fail enable register) (mt8852b and mt8852b-042 only) the bits in the edr eut fail enable register are the same as those in the edr eut fail register. The two...

  • Page 38

    Ieee 488.2 mandatory and register commands mt8852b programming manual pn: 13000-00110 rev. V 3-3 *eetf (edr eut fail register query) (mt8852b and mt8852b-042 only) returns the current state of the edr eut fail register (eetf). *ese (standard event status enable) the bits in the standard event status...

  • Page 39

    Ieee 488.2 mandatory and register commands 3-4 pn: 13000-00110 rev. V mt8852b programming manual *esr (standard event status register query) returns the current state of the standard event register (esr). *ete (eut fail enable register) the bits in the eut fail enable register are the same as those ...

  • Page 40: *idn (Identification Query)

    Ieee 488.2 mandatory and register commands mt8852b programming manual pn: 13000-00110 rev. V 3-5 *etf (eut fail register query) returns the current state of the eut fail register (etf). *idn (identification query) query command format *etf? Response is a decimal representation of the binary value of...

  • Page 41

    Ieee 488.2 mandatory and register commands 3-6 pn: 13000-00110 rev. V mt8852b programming manual *ine (instrument status enable register) the bits in the instrument status enable register are the same as those in the instrument status register. The two registers are bitwise and’ed to determine which...

  • Page 42

    Ieee 488.2 mandatory and register commands mt8852b programming manual pn: 13000-00110 rev. V 3-7 *leete (ble eut fail enable register) (option 27 and mt8852b-043 only) the bits in the ble eut fail enable register are the same as those in the ble eut fail register. The two registers are bitwise and'e...

  • Page 43: *rst (Instrument Reset)

    Ieee 488.2 mandatory and register commands 3-8 pn: 13000-00110 rev. V mt8852b programming manual *opc (operation completed indication) these commands generate indications when all pending operations are completed. An operation is complete when all input messages processed and all responses have been...

  • Page 44

    Ieee 488.2 mandatory and register commands mt8852b programming manual pn: 13000-00110 rev. V 3-9 *sre (service request enable register) the bits in the service request enable register (sre) are the same as those in the status byte register (stb) except for bit 6, which is not used in the sre. With t...

  • Page 45: *tst (Self Test Query)

    Ieee 488.2 mandatory and register commands 3-10 pn: 13000-00110 rev. V mt8852b programming manual *tst (self test query) invokes an instrument self-test cycle and places the results in the output queue *wai (wait to continue) this mandatory iee488.2 command is decoded but produces no action because ...

  • Page 46: Chapter 4 — General Gpib

    Mt8852b programming manual pn: 13000-00110 rev. V 4-1 chapter 4 — general gpib commands bootstatus? (startup self test status request ) cont (continue after self test) query command format bootstatus? Remarks on startup the instrument performs a self test. If the self test fails, a warning screen is...

  • Page 47: Errlst (Error List)

    General gpib commands 4-2 pn: 13000-00110 rev. V mt8852b programming manual errlst (error list) this command reads out and clears the recorded error states latch. The error states latch records an error occurring and retains the error states until the instrument is reset, the power is cycled, or the...

  • Page 48

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-3 11 error finding start of packet using power profile 12 error locating p0/gfsk sync word 13 location of p0/gfsk sync word exceeds allowed limits 14 error locating edr sync word 15 location of edr sync word exceeds allowed li...

  • Page 49

    General gpib commands 4-4 pn: 13000-00110 rev. V mt8852b programming manual eutinit (bluetooth slave mode) this command puts the mt8852b into bluetooth slave mode. It is the equivalent to: .> “system features” > “connection control” > “make me an eut”. Eutmaxpwr (send eut to max power control) this ...

  • Page 50

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-5 lepktmode (set the ble data packet mode) this command sets the data mode for the bluetooth low energy (ble) tests. Lkpass (update lock/unlock password) this command enables the operator to change the script lock password. Th...

  • Page 51: Lock (Script Lock)

    General gpib commands 4-6 pn: 13000-00110 rev. V mt8852b programming manual lock (script lock) this command locks a script so that it cannot be altered unless it is unlocked with the unlock command. The enquiry version of this command will return true or false indicating whether a script has been lo...

  • Page 52: Opmd (Operation Mode)

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-7 opmd (operation mode) this command configures the operation mode of the instrument. Set command format opmd{} script script mode stest single test mode siggen signal generator mode esiggen edr signal generator mode lessiggen...

  • Page 53

    General gpib commands 4-8 pn: 13000-00110 rev. V mt8852b programming manual less ble receiver sensitivity (option 27 and mt8852b-043 only) lepri ble per report integrity test (option 27 and mt8852b-043 only) lemp ble max input signal level (option 27 and mt8852b-043 only) remarks is applicable only ...

  • Page 54: Optstatus? (Option Status)

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-9 optstatus? (option status) scptcfg (configure script) this command is used to select which tests are run as part of a script. All scripts and their tests are independent. Query command format optstatus? Remarks this command ...

  • Page 55

    General gpib commands 4-10 pn: 13000-00110 rev. V mt8852b programming manual efs edr floor sensitivity test (mt8852b and mt8852b-042 only) emp edr maximum input power test (mt8852b and mt8852b-042 only) epc enhanced power control leop ble output power (option 27 and mt8852b-043 only) lemi ble modula...

  • Page 56

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-11 • carrier drift • single slot sensitivity • multi slot sensitivity • max input power • edr relative transmit power test (mt8852b and mt8852b-042 only) • edr carrier frequency stability and modulation accuracy test (mt8852b ...

  • Page 57: Scptnm (Set Script Name)

    General gpib commands 4-12 pn: 13000-00110 rev. V mt8852b programming manual scptnm (set script name) set or request the script name. The anritsu predefined scripts names cannot be set. Scptrst (reset script) this command resets a script to its default values. Set command format scptnm 3 to 10 scrip...

  • Page 58: Scptsel (Select Script)

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-13 scptsel (select script) set or request the selected script to be executed. If this command is sent when in single test mode, the selected test is executed. Scpttstgp (set test group state) (mt8852b and mt8852b-042 only) thi...

  • Page 59: Scriptmode (Script Mode)

    General gpib commands 4-14 pn: 13000-00110 rev. V mt8852b programming manual scriptmode (script mode) this command determines how the tests within the specified script are run. Set command format scriptmode 3 to 10 standard nullpkt singlepayload example set the script mode for script 3 to null packe...

  • Page 60: Status (Status Command)

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-15 status (status command) this command requests the instrument measurement status. It can be sent any time. If it is sent while a script is running, it provides information about the measurement that is currently in progress....

  • Page 62

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-17 ooo ble test selected: (models with option 27 only) lepri ble per report integrity leop ble output power test lemi ble modulation characteristics test leic ble carrier frequency offset and drift test less ble receiver sensi...

  • Page 63: Self Test Items

    General gpib commands 4-18 pn: 13000-00110 rev. V mt8852b programming manual sterr (request post or *tst? Results) this command returns the results of the most recent self-test. It does not initiate a self-test itself. Self test items the following is a list of all self-test items. For more informat...

  • Page 64

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-19 dspram indicates the type of test that failed, indicates the type of ram where the failure occurred and is the list of addresses where the test failed. Dspif dsp interface error. Uart indicates the type of test that failed ...

  • Page 65: Tstpause (Test Pause)

    General gpib commands 4-20 pn: 13000-00110 rev. V mt8852b programming manual tstpause (test pause) this command specifies whether a test pause lmp test control is used between changes in a test control format. Txpwr (transmitter power level) this command sets the default transmitter power level for ...

  • Page 66: Unlock (Script Unlock)

    General gpib commands mt8852b programming manual pn: 13000-00110 rev. V 4-21 unlock (script unlock) this command will unlock a locked script so that it can be altered. If the unlock failed, an execution error is indicated set command format unlock 3 to 10 the lock/unlock password. Default is “1234”....

  • Page 67

    General gpib commands 4-22 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 68

    Mt8852b programming manual pn: 13000-00110 rev. V 5-1 chapter 5 — system configuration this chapter provides details of the system configuration command and the associated parameters. The commands are listed in alphabetical order as detailed below. Syscfg (set or query system configuration) • auth (...

  • Page 70

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-3 bncoutput (rear panel output) this command defines the output directed to the rear panel bnc outputs. The allowable selections are restricted as follows: • output 1 cannot be rxon and output 2 cannot be txon. • if output 1 is...

  • Page 72

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-5 gpib (tester gpib address) lktimo (link timeout setting) this command sets the amount of time the unit waits after loosing a (bluetooth) link before abandoning the connection. This command is used before a link is made. Set c...

  • Page 73

    System configuration 5-6 pn: 13000-00110 rev. V mt8852b programming manual modindex (mod index setting) the mt8852b default setting for the modulation index of the communication channel is 0.32. This command allows this value to be changed. Set command format syscfgconfigmodindex 0.25 to 0.50 exampl...

  • Page 74

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-7 npmode (poll/null measurement mode) this command has been maintained to ensure compatibility with software version 1.00. It should not be used in any of the new test programs and ideally should be replaced in existing test pr...

  • Page 75

    System configuration 5-8 pn: 13000-00110 rev. V mt8852b programming manual range (tester measurement system power range) this command allows the power range of the measurement system to be controlled if required. There are six power ranges plus auto ranging which is the default. Set command format s...

  • Page 76

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-9 rs232 (tester communication rs232 baud rate) set command format syscfgconfigrs232 1200 2400 4800 9600 19200 38400 57600 example to set the baud rate to 19200 the command would be: syscfg config,rs232,19200 query command forma...

  • Page 77

    System configuration 5-10 pn: 13000-00110 rev. V mt8852b programming manual rsmode (tester rear panel rs232 mode) this command sets the rear panel rs232 into one of the following modes: extcom the connector can be used for gpib type control and communication. Exthci the connector is used to send hci...

  • Page 79

    System configuration 5-12 pn: 13000-00110 rev. V mt8852b programming manual entry (error beep on illegal entry) this command sets the instrument to make an audible beep when an illegal entry is made from the front panel. Foltst (follow test mode) this command is used to set the follow test display m...

  • Page 80

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-13 key (tactile feedback control ‘key click’) this command controls the key click from the front panel keypad. Text (user text string) set command format syscfgdispsoundkey on or off example to turn on the key click the command...

  • Page 81

    System configuration 5-14 pn: 13000-00110 rev. V mt8852b programming manual texts (user text display state) set command format syscfgdispsoundtexts on or off example to set the user text display state to on, the command would be: syscfg dispsound,texts,on query command format syscfg?Dispsoundtexts r...

  • Page 82: Eutaddr (Eut Address)

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-15 eutaddr (eut address) this command is used to set the eut address when the eut address source is set to manual. If the source is not set to manual the command is ignored and an execution error given. The query command is use...

  • Page 83

    System configuration 5-16 pn: 13000-00110 rev. V mt8852b programming manual eutname (eut user friendly name request) this command returns the user-friendly name of the eut if it is available. When a test or script is run the standard connection procedure requests the user-friendly name. If the conne...

  • Page 84

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-17 query command format syscfg?Eutrs232 response the response is returned in the form of the command to set that state. Example syscfg? Eutrs232 response for baud rate set to 19200 the response would be: syscfg eutrs232,19200

  • Page 85: Eutsrce (Eut Address Source)

    System configuration 5-18 pn: 13000-00110 rev. V mt8852b programming manual eutsrce (eut address source) set command format syscfgeutsrce manual rs232 inquiry usb ble2wire usbadaptor remarks this command is used to set the source of the eut address. Manual the address of the eut is entered via the f...

  • Page 86: Ident (Tester Identity)

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-19 hwinfo (hardware information) this command returns the rf pcb serial number and revision and the control pcb serial number and revision. Ident (tester identity) this command allows the operator to read the identity, serial n...

  • Page 87: Inqset (Inquiry Set Up)

    System configuration 5-20 pn: 13000-00110 rev. V mt8852b programming manual inqset (inquiry set up) this command configures the inquiry. The inquiry continues until the maximum number of responses has been reached or the maximum period of time has expired. The inquiry can also be terminated by the i...

  • Page 88

    System configuration mt8852b programming manual pn: 13000-00110 rev. V 5-21 timeout (maximum inquiry time) the inquiry can be configured to stop after a maximum period of time. The command parameters used to set this value. Set command format syscfginqsettimeout 5 to 60 (timeout in seconds) example ...

  • Page 91

    System configuration 5-24 pn: 13000-00110 rev. V mt8852b programming manual lpstfail (loop test/script stop on fail) when running a test or script in loop mode this command allows the testing to stop on a test failing. Frqdisp (frequency display mode) this command sets the way that the bluetooth cha...

  • Page 93

    System configuration 5-26 pn: 13000-00110 rev. V mt8852b programming manual verdate (tester firmware version and date stamp) this command returns the version and date stamp information for all the modules within the anritsu bluetooth test set. Vernum (tester firmware version numbers) this command re...

  • Page 94

    Mt8852b programming manual pn: 13000-00110 rev. V 6-1 chapter 6 — sco configuration this chapter provides details of the sco configuration command and the associated parameters. Sco connections are used to carry audio data. A sco connection can only be set up when an acl connection has been made bet...

  • Page 95

    Sco configuration 6-2 pn: 13000-00110 rev. V mt8852b programming manual aircode (sco air code format) bitposn (sco linear pcm bit position) set command format scocfgaircode cvsd ulaw alaw remarks this command is used to set the format to be used over air for the sco connection. Both ends of the sco ...

  • Page 96

    Sco configuration mt8852b programming manual pn: 13000-00110 rev. V 6-3 inputcode (sco input coding format) inputdata (sco input data format) set command format scocfginputcode linear ulaw alaw remarks this command is used to set the input coding format for the audio connection. The value is only us...

  • Page 97

    Sco configuration 6-4 pn: 13000-00110 rev. V mt8852b programming manual lbmode (loopback mode) pkttype (sco packet type) set command format scocfglbmode on off remarks this command is used to set the unit into remote loopback mode. In this mode all data received over air (including sco data) is loop...

  • Page 98

    Sco configuration mt8852b programming manual pn: 13000-00110 rev. V 6-5 sampsize (sco input sample size) tonegen (sco tone generator) set command format scocfgsampsize 8 bit 16 bit remarks this command is used to set the input sample size for the audio connection to either 8 bit or 16 bit. The value...

  • Page 99

    Sco configuration 6-6 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 100: Scoconn (Sco Connect)

    Mt8852b programming manual pn: 13000-00110 rev. V 7-1 chapter 7 — sco connections this chapter provides details of the sco connect and disconnect commands. A sco connection can only be created when an acl connection already exists between the two units. The following list is an example gpib command ...

  • Page 101

    Sco connections 7-2 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 102

    Mt8852b programming manual pn: 13000-00110 rev. V 8-1 chapter 8 — afh measurement this chapter provides details of the adaptive frequency hopping (afh) configuration commands and associated parameters. Afh is a method used to improve the transmission quality by preventing hopping to channels that ar...

  • Page 103

    Afh measurement 8-2 pn: 13000-00110 rev. V mt8852b programming manual acm (read active channel map) afh (afh on / off) display (display channel utilization or fer page) query command format afhcfg?Acm response response is a hexadecimal representation of the active channel map. Example if all channel...

  • Page 104

    Afh measurement mt8852b programming manual pn: 13000-00110 rev. V 8-3 eutrpt (eut reporting on / off) eutrrate (eut reporting rate) fer (read frame error rate) set command format afhcfgeutrpt on or off remarks this command is used to enable or disable eut reporting. Query command format afhcfg?Eutrp...

  • Page 105

    Afh measurement 8-4 pn: 13000-00110 rev. V mt8852b programming manual minchan (minimum number of active channels) mplam (set mt8852b pseudo local assessment map) set command format afhcfgminchan 1 to 20 remarks this command is used to set the minimum number of channels that may remain as active in t...

  • Page 106

    Afh measurement mt8852b programming manual pn: 13000-00110 rev. V 8-5 scale set command format afhcfgscale 10 20 50 100 remarks this command sets the scale value used for the “chart recorder” display when measuring channel utilisation or fer. Query command format afhcfg?Scale response the response i...

  • Page 107

    Afh measurement 8-6 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 108: And Cw Measurement

    Mt8852b programming manual pn: 13000-00110 rev. V 9-1 chapter 9 — signal generator mode and cw measurement the mt8852b can be used to generate fixed data patterns at calibrated levels. The instrument can be placed into signal generator mode by using the opmd command or sending the siggen or esiggen ...

  • Page 109: Ble Signal Generator Mode

    Signal generator mode and cw measurement 9-2 pn: 13000-00110 rev. V mt8852b programming manual ble signal generator mode (option 27 and mt8852b-043 only) use this command to generate bluetooth low energy (ble) modulation schemes. Set command format lesiggen tate> 32 bit hexadecimal value. (ble defau...

  • Page 110: (Option 34 Only)

    Signal generator mode and cw measurement mt8852b programming manual pn: 13000-00110 rev. V 9-3 ble extended signal generator mode (supports data length extension) (option 34 only) use this command to generate bluetooth low energy (ble) modulation schemes. Set command format lesiggenx 32 bit hexadeci...

  • Page 111: (Options 35 and 36 Only)

    Signal generator mode and cw measurement 9-4 pn: 13000-00110 rev. V mt8852b programming manual ble extended signal generator mode (supports bluetooth 5 - 2le and blr) (options 35 and 36 only) use this command to generate bluetooth low energy (ble) modulation schemes. Set command format lepktgen 32 b...

  • Page 112

    Signal generator mode and cw measurement mt8852b programming manual pn: 13000-00110 rev. V 9-5 remarks lepktgen extends the lesiggenx to include support for bluetooth 5 (2le and blr). It is only available when option 35 (2le) and / or option 36 (blr) is installed. An additional parameter allows the ...

  • Page 114: Cw Measurement Mode

    Signal generator mode and cw measurement mt8852b programming manual pn: 13000-00110 rev. V 9-7 cw measurement mode the mt8852b can be used to measure a fixed frequency modulation signal. Power, frequency, and modulation can be measured. The opmd command can be used to put the mt8852b into cw measure...

  • Page 115

    Signal generator mode and cw measurement 9-8 pn: 13000-00110 rev. V mt8852b programming manual edr cw measurement mode (mt8852b and mt8852b-042 only) the mt8852b can be set up in cw measurement mode to allow calibration of an incoming fixed frequency signal. The instrument will measure power and dev...

  • Page 117: Mt8852B-042 Only)

    Signal generator mode and cw measurement 9-10 pn: 13000-00110 rev. V mt8852b programming manual ecwresult (edr cw measurements results output) (mt8852b and mt8852b-042 only) this command is used to fetch the measurement results from the mt8852b when configured in edr cw measurement mode. Query comma...

  • Page 118: Standard Mode

    Mt8852b programming manual pn: 13000-00110 rev. V 10-1 chapter 10 — configuring tests in standard mode basic rate tests (#1) output power (trm/ca/bv-01-c) power control (trm/ca/bv-03-c) enhanced power control (trm/ca/bv-14-c) initial carrier frequency (trm/ca/bv-08-c) carrier frequency drift (trm/ca...

  • Page 119

    Configuring tests in standard mode 10-2 pn: 13000-00110 rev. V mt8852b programming manual blr receiver sensitivity, le coded (s=2), stable modulation index (#5) (rcv-le/ca/bv-32-c) blr receiver sensitivity, le coded (s=8) (#5) (rcv-le/ca/bv-27-c) blr receiver sensitivity, le coded (s=8), stable modu...

  • Page 120: 10-1 Basic Rate Tests

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-3 10-1 basic rate tests output power test configuration (opcfg) the output power test performs power measurements on the eut transmitted packets using either the loopback test control or the tx t...

  • Page 121

    Basic rate tests configuring tests in standard mode 10-4 pn: 13000-00110 rev. V mt8852b programming manual query command format opcfg? 1 to 10 lrxfreq low rx frequency setting. Mrxfreq medium rx frequency setting. Hrxfreq high rx frequency setting. Hopmode use defined, all, or any mt8852b custom mod...

  • Page 122

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-5 power control test configuration (pccfg) the power control test performs power measurement cycles on the eut output, if the eut supports power control, at each of the defined frequencies (low, ...

  • Page 123

    Basic rate tests configuring tests in standard mode 10-6 pn: 13000-00110 rev. V mt8852b programming manual example to set the default pccfg the command would be: pccfg 3,default query command format pccfg? 1 to 10 lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequency s...

  • Page 124

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-7 enhanced power control test configuration (epccfg) the enhanced power control test performs power measurement cycles on the eut output at each of the defined frequencies (low, medium and high)....

  • Page 125

    Basic rate tests configuring tests in standard mode 10-8 pn: 13000-00110 rev. V mt8852b programming manual example to set the default epccfg the command would be: epccfg 3,default query command format epccfg? 1 to 10 lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequenc...

  • Page 126

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-9 initial carrier test configuration (iccfg) the initial carrier test performs a frequency accuracy test on a dh1 pseudo random data packet. (prbs 9) this test can be performed using either the l...

  • Page 127

    Basic rate tests configuring tests in standard mode 10-10 pn: 13000-00110 rev. V mt8852b programming manual mfreqsel read the medium frequency settings in test. Hfreqsel read the high frequency settings in test. Ltxfreq read the low frequency tx and rx value. Mtxfreq read the medium frequency tx and...

  • Page 128

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-11 carrier drift test configuration (cdcfg) the carrier drift test performs a frequency drift measurement over the length of the packet received. The test can be carried out for each of the suppo...

  • Page 129

    Basic rate tests configuring tests in standard mode 10-12 pn: 13000-00110 rev. V mt8852b programming manual lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequency settings in test. Hfreqsel read the high frequency settings in test. Ltxfreq read the low frequency tx and ...

  • Page 130

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-13 single slot sensitivity test configuration (sscfg) for a single slot sensitivity measurement the mt8852b transmits dh1 packets with a pseudo random payload (prbs 9) to the eut at a minimum pow...

  • Page 131

    Basic rate tests configuring tests in standard mode 10-14 pn: 13000-00110 rev. V mt8852b programming manual query command format sscfg? 1 to 10 lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequency settings in test. Hfreqsel read the high frequency settings in test. Lt...

  • Page 132

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-15 multi slot sensitivity test configuration (mscfg) for a multi slot sensitivity measurement the mt8852b transmits the longest supported packet type as reported by the eut during link set up wit...

  • Page 133

    Basic rate tests configuring tests in standard mode 10-16 pn: 13000-00110 rev. V mt8852b programming manual query command format mscfg? 1 to 10 lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequency settings in test. Hfreqsel read the high frequency settings in test. Lt...

  • Page 134

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-17 modulation index test configuration (micfg) this test measures the modulation characteristics on the eut output for each of the frequency ranges selected (low, medium and high). The mt8852b ca...

  • Page 135

    Basic rate tests configuring tests in standard mode 10-18 pn: 13000-00110 rev. V mt8852b programming manual example to set the default micfg the command would be: micfg 3,default query command format micfg? 1 to 10 lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequency ...

  • Page 136

    Configuring tests in standard mode basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-19 input power sensitivity test configuration (mpcfg) for the eut maximum input power test the mt8852b transmits a pseudo random payload (prbs 9) dh1 data packet to the eut so that the eut receiv...

  • Page 137

    Basic rate tests configuring tests in standard mode 10-20 pn: 13000-00110 rev. V mt8852b programming manual lrxfreq read the low frequency rx value. Mtxfreq read the medium frequency tx value. Mrxfreq read the medium frequency rx value. Htxfreq read the high frequency tx value. Hrxfreq read the high...

  • Page 138

    Configuring tests in standard mode enhanced data rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-21 10-2 enhanced data rate tests relative transmit power test configuration (erpcfg) (mt8852b and mt8852b-042 only) the edr relative transmit power measurement ensures that the difference...

  • Page 139

    Enhanced data rate tests configuring tests in standard mode 10-22 pn: 13000-00110 rev. V mt8852b programming manual specify either frequency (freq) or channel (chan). Query command format erpcfg? 1 to 10 numpkts read the number of packets. Dhxpkt read the dhx test packet type. Tstctrl read the test ...

  • Page 140

    Configuring tests in standard mode enhanced data rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-23 carrier frequency stability and modulation test configuration (ecmcfg) (mt8852b and mt8852b-042 only) this test verifies the transmitter carrier frequency stability and modulation accu...

  • Page 141

    Enhanced data rate tests configuring tests in standard mode 10-24 pn: 13000-00110 rev. V mt8852b programming manual htxfreq high tx frequency. Lfreqsel use the low frequency settings in test. Mfreqsel use the medium frequency settings in test. Hfreqsel use the high frequency settings in test. Initfr...

  • Page 142

    Configuring tests in standard mode enhanced data rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-25 initfrqlh read the initial frequency error upper limit value. Initfrqll read the initial frequency error lower limit value. Freqerlh read the frequency error upper limit value. Freqerl...

  • Page 143

    Enhanced data rate tests configuring tests in standard mode 10-26 pn: 13000-00110 rev. V mt8852b programming manual differential phase encoding test configuration (edpcfg) (mt8852b and mt8852b-042 only) in this measurement the eut transmits a packet with a defined prbs9 payload. The payload of the r...

  • Page 144

    Configuring tests in standard mode enhanced data rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-27 pctpkt read the percentage of packets with no errors limit value. Response the response is returned in the form of the command to set that state. Note refer to chapter 12 for details o...

  • Page 145

    Enhanced data rate tests configuring tests in standard mode 10-28 pn: 13000-00110 rev. V mt8852b programming manual edr sensitivity test configuration (ebscfg) (mt8852b and mt8852b-042 only) the sensitivity test case is to test the eut receiver sensitivity performance in terms of bit error rate usin...

  • Page 146

    Configuring tests in standard mode enhanced data rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-29 query command format ebscfg? 1 to 10 dhxpkt read the dhx test packet type to use. Dirtytx read the dirty table parameters. Dirtytab read the dirty table. Drifts read the drift status. ...

  • Page 147

    Enhanced data rate tests configuring tests in standard mode 10-30 pn: 13000-00110 rev. V mt8852b programming manual edr ber floor sensitivity test configuration (efscfg) (mt8852b and mt8852b-042 only) the ber floor performance test case is to test whether the eut receiver sensitivity has low residua...

  • Page 148

    Configuring tests in standard mode enhanced data rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-31 query command format efscfg? 1 to 10 dhxpkt read the dhx test packet type to use. Pktcount read the method used to count packets. Hopping read the hopping stages. Thbitcnt read the thr...

  • Page 149

    Enhanced data rate tests configuring tests in standard mode 10-32 pn: 13000-00110 rev. V mt8852b programming manual edr maximum input power test configuration (empcfg) (mt8852b and mt8852b-042 only) the edr maximum input level test case is to test whether the eut receiver sensitivity has low ber per...

  • Page 150

    Configuring tests in standard mode enhanced data rate tests mt8852b programming manual pn: 13000-00110 rev. V 10-33 numbits read the number of bits. Hopping read the hopping stages. Pktcount read the method used to count packets. Lrxfreq read the low rx frequency. Mrxfreq read the medium rx frequenc...

  • Page 151: 10-3 Low Energy Tests

    Low energy tests configuring tests in standard mode 10-34 pn: 13000-00110 rev. V mt8852b programming manual 10-3 low energy tests (option 27 and mt8852b-043 only) ble output power test configuration (leopcfg) the output power test performs power measurements on the eut transmitted packets. The mt885...

  • Page 152

    Configuring tests in standard mode low energy tests mt8852b programming manual pn: 13000-00110 rev. V 10-35 query command format leopcfg? 1 to 10 lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequency settings in test. Hfreqsel read the high frequency settings in test. ...

  • Page 153

    Low energy tests configuring tests in standard mode 10-36 pn: 13000-00110 rev. V mt8852b programming manual ble carrier frequency offset and drift test configuration (leicdcfg) (option 27 and mt8852b-043 only) the carrier drift test performs an initial carrier frequency offset, drift and drift rate ...

  • Page 154

    Configuring tests in standard mode low energy tests mt8852b programming manual pn: 13000-00110 rev. V 10-37 dftblelrrat e set the drift rate limit (blr). Default set the test to its default settings (set only). Specify either frequency (freq) or channel (chan). Example to set the default leicdcfg th...

  • Page 155

    Low energy tests configuring tests in standard mode 10-38 pn: 13000-00110 rev. V mt8852b programming manual response the response is returned in the form of the command to set that state. Example leicdcfg? 3,numpkts response if the value of the cdcfg numpkts was 25, the response would be: leuicdcfg ...

  • Page 156

    Configuring tests in standard mode low energy tests mt8852b programming manual pn: 13000-00110 rev. V 10-39 ble modulation characteristics test configuration (lemicfg) (option 27 and mt8852b-043 only) this test measures the modulation characteristics of the eut output for each of the frequency range...

  • Page 157

    Low energy tests configuring tests in standard mode 10-40 pn: 13000-00110 rev. V mt8852b programming manual f1avg2min set the f1avg 2le min limit. F1avg2max set the f1avg 2le max limit. F1avg2smin set the f1avg 2le min limit (stable modulation index). F1avg2smax set the f1avg 2le max limit (stable m...

  • Page 158

    Configuring tests in standard mode low energy tests mt8852b programming manual pn: 13000-00110 rev. V 10-41 f1avgmin read the f1avg min limit. F1avgmax read the f1avg max limit. F1avgsmin set the f1avg min limit (stable modulation index). F1avgsmax read the f1avg max limit (stable modulation index)....

  • Page 159

    Low energy tests configuring tests in standard mode 10-42 pn: 13000-00110 rev. V mt8852b programming manual ble receiver sensitivity test configuration (lesscfg) (option 27 and mt8852b-043 only) for ble sensitivity measurement the mt8852b first sends the ble rx test command to the eut and then trans...

  • Page 160

    Configuring tests in standard mode low energy tests mt8852b programming manual pn: 13000-00110 rev. V 10-43 query command format lesscfg? 1 to 10 lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequency settings in test. Hfreqsel read the high frequency settings in test. ...

  • Page 161

    Low energy tests configuring tests in standard mode 10-44 pn: 13000-00110 rev. V mt8852b programming manual ble per report integrity (lepricfg) (option 27 and mt8852b-043 only) the mt8852b sends ble reference packets with a prbs9 payload at a power level of -30 dbm and with the crc value alternating...

  • Page 162

    Configuring tests in standard mode low energy tests mt8852b programming manual pn: 13000-00110 rev. V 10-45 numcyc read the number or cycles of the test. Lepkttype read the packet type. Letstmode read the test mode: standard or stable modulation index. Numpkts read the number of packets used for eac...

  • Page 163

    Low energy tests configuring tests in standard mode 10-46 pn: 13000-00110 rev. V mt8852b programming manual ble maximum input signal level test configuration (lempcfg) (option 27 and mt8852b-043 only) for the ble maximum input signal level measurement the mt8852b first sends the ble rx test command ...

  • Page 164

    Configuring tests in standard mode low energy tests mt8852b programming manual pn: 13000-00110 rev. V 10-47 query command format lempcfg? 1 to 10 lfreqsel read the low frequency settings in test. Mfreqsel read the medium frequency settings in test. Hfreqsel read the high frequency settings in test. ...

  • Page 165

    Low energy tests configuring tests in standard mode 10-48 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 166: Single Payload Mode

    Mt8852b programming manual pn: 13000-00110 rev. V 11-1 chapter 11 — configuring tests in single payload mode 11-1 single payload configuration (spcfg) this command is used to configure parameters when test scripts are carried out in single payload mode (see operation manual for more information on t...

  • Page 167

    Single payload configuration (spcfg) configuring tests in single payload mode 11-2 pn: 13000-00110 rev. V mt8852b programming manual 1 to 10 tstctrl read test control to be used in test payload read the test control payload type pkttype read type to use in performing test hopstate read the hopping m...

  • Page 168: Variables

    Mt8852b programming manual pn: 13000-00110 rev. V 12-1 chapter 12 — test parameter variables this section provides details of the non-limit type variables that may be used for all or any of the tests. For ease of referencing, the variables are listed in alphabetical order. Actual frequencies used (l...

  • Page 169

    Test parameter variables 12-2 pn: 13000-00110 rev. V mt8852b programming manual set command format pccfg [suffix] 3 to 10 ltxfreq low tx frequency (also rx frequency when in tx test control mode). Lrxfreq low rx frequency setting. Lfreq sets both tx and rx low frequencies when in tx test control mod...

  • Page 170

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-3 query command format pccfg? 1 to 10 ltxfreq tx frequency (also rx frequency when in tx test control mode). Lrxfreq low rx frequency setting. Lfreq tx and rx low frequencies when in tx test control mode. Mtxfreq medium tx...

  • Page 171: Default

    Test parameter variables 12-4 pn: 13000-00110 rev. V mt8852b programming manual default this parameter applies to all tests and will set that test back to its default settings. Dhxpkt (mt8852b and mt8852b-042 only) this parameter is used to set up the edr packet type to be used in both the 2 mbps an...

  • Page 172: Dirtytab

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-5 dirtytab this parameter is used with the edr sensitivity test, multi-slot sensitivity and single slot sensitivity tests where the dirty parameter table is available. The command allows a single entry or all entries for a...

  • Page 173: Dirtytx

    Test parameter variables 12-6 pn: 13000-00110 rev. V mt8852b programming manual dirtytx this parameter is used to set or read whether the dirty transmitter is applied during the single slot and multi slot sensitivity tests, and single payload test when a payload of prbs9 is used. Query command forma...

  • Page 174

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-7 frequencies used (lfreqsel, mfreqsel, hfreqsel) these parameters are used to select or read whether the low, medium or high frequencies are used when the test is run. Set command format pccfg 3 to 10 lfreqsel mfreqsel hf...

  • Page 175: Drifts

    Test parameter variables 12-8 pn: 13000-00110 rev. V mt8852b programming manual drifts this application turns on or off the application of drift as specified in the rf bluetooth test specification. Ferlimmode following the introduction of support for data length extension (dle) with option 34, this ...

  • Page 176: Hopmode

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-9 hopmode when a test is run with hopping on, this parameter is used to set which packets in the hop sequence are used for measurement. Set command format iccfg 3 to 10 defined all any example to set hopping mode in script...

  • Page 177: Hopping

    Test parameter variables 12-10 pn: 13000-00110 rev. V mt8852b programming manual hopping some of the tests can be done in both hopping on and hopping off states. This parameter is used to set or read in which states the test is done when a test with this parameter is run. Set command format iccfg 3 ...

  • Page 178: Hopstate

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-11 hopstate the single payload test can be performed in both hopping on and hopping off states. This parameter is used to set or read in which state the single payload test is performed. Set command format spcfg 3 to 10 on...

  • Page 179: Lepkttype

    Test parameter variables 12-12 pn: 13000-00110 rev. V mt8852b programming manual lepkttype (mt8852b-027 and mt8852b-043 with options 35, 36, 62 only) this configuration parameter is used to set the bluetooth low energy packet type. It is used with the following ble test configuration commands: leopc...

  • Page 180

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-13 example to set the packet type to lr2 (only) for the single sensitivity test in script 3 the commands are: lesscfg 3,lepkttype,lr2,true lesscfg 3,lepkttype,lr8,false lesscfg 3,lepkttype,2le,false lesscfg 3,lepkttype,ble...

  • Page 181: Letstmode

    Test parameter variables 12-14 pn: 13000-00110 rev. V mt8852b programming manual letstmode (mt8852b-027 and mt8852b-043 only) this configuration parameter is used to specify testing of bluetooth low energy devices that have a stable modulation index phy. It specifies whether stable, standard or both...

  • Page 182: Mincheck

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-15 mincheck (mt8852b and mt8852b-042 only) this parameter is used in the edr relative power test only. If the eut supports power control and its minimum power is less than the mt8852b measurement receiver sensitivity, this...

  • Page 183: Minpwr

    Test parameter variables 12-16 pn: 13000-00110 rev. V mt8852b programming manual minpwr this parameter is used to set or read the required minimum eut tx power level the power control test will step to if the eut has not already reached it’s minimum. Numbits (mt8852b and mt8852b-042 only) this param...

  • Page 184: Numcyc

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-17 numblks (mt8852b and mt8852b-042 only) this parameter is used to define the number of blocks over which the edr carrier frequency stability and modulation accuracy test is to be performed. Numcyc this parameter is used ...

  • Page 185: Numpkts

    Test parameter variables 12-18 pn: 13000-00110 rev. V mt8852b programming manual numpkts this parameter is used to set or read the number of packets that are used for each part of the test. For each of the low, medium and high frequencies selected to be used as part of the test, this is the number o...

  • Page 186: Payload

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-19 payload this sets the payload data for the packet type defined. Pktcount this parameter is used to configure how the packets are counted during this test. If the packet count is set to transmitted packets the test may n...

  • Page 187: Pktnummode

    Test parameter variables 12-20 pn: 13000-00110 rev. V mt8852b programming manual pktnummode (option 27 and mt8852b_043 only) this parameter configures whether the ble per integrity test is run using a fixed or random number of packets. The numpkts parameter is used only to define the number of packe...

  • Page 188: Pktsize

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-21 pktsize this parameter is used to set or read the packet sizes used for the carrier drift test. The test can be performed with all or any combination of the dh1, dh3 or dh5 packets depending on which packet types the eu...

  • Page 189: Pkttype

    Test parameter variables 12-22 pn: 13000-00110 rev. V mt8852b programming manual pkttype this parameter is used to set or read the packet type used for a test. The valid parameters depended on the test and whether an eut supports that packet type. The packet types that can be selected from the list ...

  • Page 190: Pwrdelay

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-23 ptxlev (mt8852b and mt8852b-042 only) this parameter is used to define whether the edr relative transmit power test (erpcfg) should be carried out at minimum and/or maximum power levels. Pwrdelay this parameter is used ...

  • Page 191: Toggle

    Test parameter variables 12-24 pn: 13000-00110 rev. V mt8852b programming manual thbitcnt (mt8852b and mt8852b-042 only) this parameter is used to set up the threshold bit count for the edr sensitivity tests. Toggle the modulation index test as defined in the rf test spec requires a measurement made...

  • Page 192: Tstctrl

    Test parameter variables mt8852b programming manual pn: 13000-00110 rev. V 12-25 tstctrl this parameter is used to configure the test control type to be applied on a test-by-test basis. All test that support both loopback and tx mode are listed below with their default value setting. Output power (o...

  • Page 193: Txpwr

    Test parameter variables 12-26 pn: 13000-00110 rev. V mt8852b programming manual ttbitcnt (mt8852b and mt8852b-042 only) this parameter is used to set up the total bit count for the edr sensitivity tests. Txpwr this parameter is used to configure the required tx power level during the sensitivity te...

  • Page 194: Avgmxlim, Avgmnlim, Peaklim

    Mt8852b programming manual pn: 13000-00110 rev. V 13-1 chapter 13 — test limit variables this chapter provides details of the limit variables for each of the tests. 13-1 output power test limit commands avgmxlim, avgmnlim, peaklim these parameters are used to set or read the limits used to determine...

  • Page 195: Mxsteplim, Mnsteplim

    Power control test limit commands test limit variables 13-2 pn: 13000-00110 rev. V mt8852b programming manual 13-2 power control test limit commands mxsteplim, mnsteplim these parameters are used in the power control test configuration to set or read the power step limits. If the step sizes are not ...

  • Page 196

    Test limit variables enhanced power control test limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-3 13-3 enhanced power control test limit commands mxsteplim, mnsteplim, mxepclim these parameters are used to setup the upper limit for the difference between the gfsk packet and the ...

  • Page 197: Mxposlim, Mxneglim

    Initial carrier frequency test limit commands test limit variables 13-4 pn: 13000-00110 rev. V mt8852b programming manual 13-4 initial carrier frequency test limit commands mxposlim, mxneglim these parameters are used to set or read the maximum positive or negative offset limits for the initial carr...

  • Page 198

    Test limit variables carrier frequency drift limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-5 13-5 carrier frequency drift limit commands dft1lim, dft3lim, dft5lim, dftnplim, dftrate these parameters are used to set or read the drift limit values in the carrier drift test. The d...

  • Page 199: Berlim, Ferlim

    Standard rate sensitivity test limit commands test limit variables 13-6 pn: 13000-00110 rev. V mt8852b programming manual 13-6 standard rate sensitivity test limit commands berlim, ferlim these parameters are used to set or read the ber/fer limit value used in the sensitivity tests. Set command form...

  • Page 200

    Test limit variables modulation index limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-7 13-7 modulation index limit commands f1avgmin, f1avgmax, f2maxlim, f1f2max these parameters are used to set or read the limit values used in the modulation characteristic test to determine if ...

  • Page 201: Pdiffll, Pdifflh

    Edr relative transmit power limit commands test limit variables 13-8 pn: 13000-00110 rev. V mt8852b programming manual 13-8 edr relative transmit power limit commands (mt8852b and mt8852b-042 only) pdiffll, pdifflh pdiffll – pdpsk to pgfsk difference window lower limit this parameter is used to set ...

  • Page 202

    Test limit variables edr relative transmit power limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-9 pdifflh – pdpsk to pgfsk difference window upper limit this parameter is used to set up the upper limit for the average power difference window for the edr relative power test pass-...

  • Page 203

    Edr carrier frequency and accuracy limit commands test limit variables 13-10 pn: 13000-00110 rev. V mt8852b programming manual 13-9 edr carrier frequency and accuracy limit commands (mt8852b and mt8852b-042 only) initfrqlh, initfrqll, freqerlh, freqerll, blkfrqlh, blkfrqll, lrmsdevm, hrmsdevm, lpkde...

  • Page 204

    Test limit variables edr carrier frequency and accuracy limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-11 initfrqll - initial frequency error lower limit value this parameter is used to set up the initial frequency error lower limit value for the edr carrier frequency and modula...

  • Page 205

    Edr carrier frequency and accuracy limit commands test limit variables 13-12 pn: 13000-00110 rev. V mt8852b programming manual freqerll - frequency error lower limit value this parameter is used to set up the frequency error lower limit value for the edr carrier frequency and modulation accuracy tes...

  • Page 206

    Test limit variables edr carrier frequency and accuracy limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-13 blkfrqll - block frequency error lower limit value this parameter is used to set up the block frequency error lower limit value for the edr carrier frequency and modulation ...

  • Page 207

    Edr carrier frequency and accuracy limit commands test limit variables 13-14 pn: 13000-00110 rev. V mt8852b programming manual hrmsdevm - 3mbps rms devm limit value this parameter is used to set up the 3mbps rms devm limit value for the edr carrier frequency and modulation accuracy test. Lpkdevm - 2...

  • Page 208

    Test limit variables edr carrier frequency and accuracy limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-15 hpkdevm - 3mbps peak devm limit value this parameter is used to set up the 3mbps peak devm limit value for the edr carrier frequency and modulation accuracy test. Lpctdevm -...

  • Page 209

    Edr carrier frequency and accuracy limit commands test limit variables 13-16 pn: 13000-00110 rev. V mt8852b programming manual hpctdevm - 3mbps 99% packets devm limit value this parameter is used to set up the 3mbps 99% packets devm limit value for the edr carrier frequency and modulation accuracy t...

  • Page 210

    Test limit variables edr differential phase encoding limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-17 13-10 edr differential phase encoding limit commands (mt8852b and mt8852b-042 only) pctpkt - percentage of packets with no errors limit value this parameter is used to set up t...

  • Page 211: Therr, Tterr

    Edr sensitivity and edr ber floor limit commands test limit variables 13-18 pn: 13000-00110 rev. V mt8852b programming manual 13-11 edr sensitivity and edr ber floor limit commands (mt8852b and mt8852b-042 only) therr, tterr therr - threshold error limit this parameter is used to set up the threshol...

  • Page 212

    Test limit variables edr sensitivity and edr ber floor limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-19 tterr - total test error limit this parameter is used to set up the total test error limit for the edr sensitivity test (ebscfg) and the edr ber floor sensitivity test (efscf...

  • Page 213

    Edr maximum input power limits test limit variables 13-20 pn: 13000-00110 rev. V mt8852b programming manual 13-12 edr maximum input power limits (mt8852b and mt8852b-042 only) this parameter is used to set or read the ber limit value used in the edr maximum input power test. Note that different unit...

  • Page 214: Avgmxlim, Avgmnlim, Peaklim

    Test limit variables ble output power test limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-21 13-13 ble output power test limit commands (mt8852b-043 and option 27 units only) avgmxlim, avgmnlim, peaklim these parameters are used to set or read the limits used to determine if the...

  • Page 215: Dftblelrrate

    Ble carrier frequency offset and drift limit commands test limit variables 13-22 pn: 13000-00110 rev. V mt8852b programming manual 13-14 ble carrier frequency offset and drift limit commands (mt8852b-043 and option 27 units only) mxposlim, mxposlrlim, mxneglim, mxneglrlim, dftblelim, dftblelrlim, in...

  • Page 216

    Test limit variables ble carrier frequency offset and drift limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-23 dftblelrrate set the drift rate limit - blr. Range 1 to 90 khz (default 19.2 khz/48 s) example to set the ble carrier drift limit to +/– 70 khz in script 4 the command ...

  • Page 217

    Ble modulation characteristics limit commands test limit variables 13-24 pn: 13000-00110 rev. V mt8852b programming manual 13-15 ble modulation characteristics limit commands (mt8852b-043 and option 27 units only. 2le requires option 35 and blr requires option 36 or 62) f1avgmin, f1avgmax, f1avgsmin...

  • Page 218

    Test limit variables ble modulation characteristics limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-25 ranges depend on the parameter : f1avgmin range –350 to +350 khz (default 225 khz) f1avgmax range –350 to +350 khz (default 275 khz) f1avgsmin range –350 to +350 khz (default 24...

  • Page 219

    Ble modulation characteristics limit commands test limit variables 13-26 pn: 13000-00110 rev. V mt8852b programming manual f1avg2smax read the f1avg max limit - stable modulation index (2le) f2maxlim read the f2max limit (ble) f2maxslim read the f2max limit - stable modulation index (ble) f1maxlim r...

  • Page 220: Ferlim

    Test limit variables ble sensitivity test and maximum input limit commands mt8852b programming manual pn: 13000-00110 rev. V 13-27 13-16 ble sensitivity test and maximum input limit commands (mt8852b-043 and option 27 units only) ferlim these parameters are used to set or read the fer limit value us...

  • Page 221: Lowperlim, Highperlim

    Ble per report integrity test limit commands test limit variables 13-28 pn: 13000-00110 rev. V mt8852b programming manual 13-17 ble per report integrity test limit commands (mt8852b-043 and option 27 units only) lowperlim, highperlim these parameters configure the ble per integrity test limits. Set ...

  • Page 222: Code

    Mt8852b programming manual pn: 13000-00110 rev. V 14-1 chapter 14 — running and aborting code running tests (run) this command runs either the test or the script depending on the operation mode. Refer to the operation mode command (opmd) for details. Aborting tests (abort) this command aborts the te...

  • Page 223

    Running and aborting code 14-2 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 224: Data

    Mt8852b programming manual pn: 13000-00110 rev. V 15-1 chapter 15 — reading test results data the commands listed in this section request measurement results for the bluetooth tests or scripts that were last run. If measurement results are requested while a script or test is ongoing, an execution er...

  • Page 225: 15-1 Summary Results

    Summary results reading test results data 15-2 pn: 13000-00110 rev. V mt8852b programming manual 15-1 summary results set command format oresultscript or oresulttest extension code: 0 to n (n is test dependent). If a test does not support a given extension code the next valid lower code is used (0 =...

  • Page 226

    Reading test results data summary results mt8852b programming manual pn: 13000-00110 rev. V 15-3 lessstb ble receiver sensitivity, stable modulation index (#3) less2m 2le receiver sensitivity (#4) less2mstb 2le receiver sensitivity, stable modulation index (#4) lesslr8 blr8 receiver sensitivity (#5)...

  • Page 227

    Summary results reading test results data 15-4 pn: 13000-00110 rev. V mt8852b programming manual example to request the standard results for the output power test only, the command would be: oresult test,0,op to request the whole script standard results (extension code 0), the command would be: ores...

  • Page 228

    Reading test results data summary results output format mt8852b programming manual pn: 13000-00110 rev. V 15-5 15-2 summary results output format set command format , 2 to 11 ascii characters indicating which test the results are for. Op output power (#1) pc power control (#1) epc enhanced power con...

  • Page 229

    Summary results output format reading test results data 15-6 pn: 13000-00110 rev. V mt8852b programming manual lesslr2 blr2 single slot sensitivity (#5) lesslr2stb blr2 receiver sensitivity, stable modulation index (#5) lepri ble per report integrity (#3) lepristb ble per report integrity, stable mo...

  • Page 230

    Reading test results data summary results output format mt8852b programming manual pn: 13000-00110 rev. V 15-7 example 1 when sending the following command to request the output power test results: oresult test,0,op the summary output power test results, extension code 0, would be: op0, where for th...

  • Page 231

    Extended results data output reading test results data 15-8 pn: 13000-00110 rev. V mt8852b programming manual 15-3 extended results data output set command format xresult[] op output power (#1) pc power control (#1) epc enhanced power control (#1) mi modulation index (#1) ic initial carrier (#1) cd ...

  • Page 232

    Reading test results data extended results data output mt8852b programming manual pn: 13000-00110 rev. V 15-9 lesslr8stb blr8 receiver sensitivity, stable modulation index (#5) lesslr2 blr2 receiver sensitivity (#5) lesslr2stb blr2 receiver sensitivity, stable modulation index (#5) lepri ble per rep...

  • Page 233

    Extended results data output reading test results data 15-10 pn: 13000-00110 rev. V mt8852b programming manual hoponanymax hopping on, any channel, max power hopofflmin hopping off, low frequency, min power hopofflmax hopping off, low frequency, max power hopoffmmin hopping off, mid frequency, min p...

  • Page 234

    Reading test results data extended results output format mt8852b programming manual pn: 13000-00110 rev. V 15-11 15-4 extended results output format set command format [], ascii characters indicating which test the results are for. Xop output power (#1) xpc power control (#1) xepc enhanced power con...

  • Page 235

    Extended results output format reading test results data 15-12 pn: 13000-00110 rev. V mt8852b programming manual xlesslr2 blr2 receiver sensitivity (#5) xlesslr2stb blr2 receiver sensitivity, stable modulation index (#5) xlepri ble per report integrity (#3) xlepristb ble per report integrity, stable...

  • Page 236

    Reading test results data extended results output format mt8852b programming manual pn: 13000-00110 rev. V 15-13 example 1 when sending the following command to request the edr relative power test results: xresult erp,hopofflmax the formatting for the extended edr relative power test results is: xer...

  • Page 247

    Basic rate tests reading test results data 15-24 pn: 13000-00110 rev. V mt8852b programming manual fer length integer e.G. 1 fer lost integer e.G. 4 packets received integer e.G. 7404 bit errors integer e.G. 11 frame errors integer e.G. 8 packets sent integer e.G. 7408 example: xss,hopoffl,true,0.19...

  • Page 248

    Reading test results data basic rate tests mt8852b programming manual pn: 13000-00110 rev. V 15-25 multi slot sensitivity test results summary results extended results refer to the extended screens section of the single slot sensitivity test. Extension codes 0: standard 1: frame error details 2: rec...

  • Page 249

    Basic rate tests reading test results data 15-26 pn: 13000-00110 rev. V mt8852b programming manual maximum input power test results summary results extended results refer to the extended screens section of the single slot sensitivity test. Extension codes 0: standard 1: frame error details 2: receiv...

  • Page 250: 15-6 Edr Tests

    Reading test results data edr tests mt8852b programming manual pn: 13000-00110 rev. V 15-27 15-6 edr tests edr relative transmit power test results (mt8852b and mt8852b-042 only) summary results extension codes 0: standard 1: gfsk absolute power readings 2: dpsk absolute power readings 3: edr packet...

  • Page 251

    Edr tests reading test results data 15-28 pn: 13000-00110 rev. V mt8852b programming manual extended results the individual stage measurements for the edr relative power test also includes extension code results. Note that there is no extension code ‘0’, as this only applies to the summary measureme...

  • Page 254

    Reading test results data edr tests mt8852b programming manual pn: 13000-00110 rev. V 15-31 extended results the individual stage measurements for the edr carrier frequency stability & modulation accuracy test also includes extension code results. Note that there is no extension code ‘0’, as this on...

  • Page 255

    Edr tests reading test results data 15-32 pn: 13000-00110 rev. V mt8852b programming manual example: xecm1,hopoffl,true,0.070,0.170,100.00,0.054,-5.0,1.7,-6.0, pass,true,0.064,0.160,100.00,0.052,-5.2,1.9,-5.8,pass,4.96e-006, 4.99e-006,4.95e-006,4.99e-006.

  • Page 256

    Reading test results data edr tests mt8852b programming manual pn: 13000-00110 rev. V 15-33 edr differential phase encoding test results (mt8852b and mt8852b-042 only) summary results extended results the individual stage measurements for this test also includes extension code results. Note that the...

  • Page 259

    Edr tests reading test results data 15-36 pn: 13000-00110 rev. V mt8852b programming manual extended results the individual stage measurements for this test also includes extension code results. Note that there is no extension code ‘0’, as this only applies to the summary measurement results. Extens...

  • Page 260

    Reading test results data edr tests mt8852b programming manual pn: 13000-00110 rev. V 15-37 example: xebs2,hopoffm,true,0.00e+000,0,300,0,true,pass,true,5.83e-007, 1,210,2,true,pass,0,0,0,2,0,0,300,210

  • Page 261

    Edr tests reading test results data 15-38 pn: 13000-00110 rev. V mt8852b programming manual ber floor sensitivity test results (mt8852b and mt8852b-042 only) summary results extension codes 0: standard 1: frame error details 2: received packets errors extension code: 0 2mbps results valid e.G. True ...

  • Page 262

    Reading test results data edr tests mt8852b programming manual pn: 13000-00110 rev. V 15-39 extended results the individual stage measurements for this test also includes extension code results. Note that there is no extension code ‘0’, as this only applies to the summary measurement results. Extens...

  • Page 263

    Edr tests reading test results data 15-40 pn: 13000-00110 rev. V mt8852b programming manual example: xefs2,hopoffm,true,0.00e+000,0,1500,0,true,pass,true,9.89e-007,8, 990,7,true,pass,0,0,0,7,0,0,1500,990

  • Page 265

    Edr tests reading test results data 15-42 pn: 13000-00110 rev. V mt8852b programming manual extended results the individual stage measurements for this test also includes extension code results. Note that there is no extension code ‘0’, as this only applies to the summary measurement results. Extens...

  • Page 266

    Reading test results data edr tests mt8852b programming manual pn: 13000-00110 rev. V 15-43 example: xemp2,hopoffm,true,3.10e-004,477,295,13,pass,true,9.35e-004,1403, 196,16,pass,1,1,12,4,2,12,283,184.

  • Page 268

    Reading test results data low energy tests mt8852b programming manual pn: 13000-00110 rev. V 15-45 ble carrier frequency offset and drift test results (mt8852b-043 and units with option 27 only) summary results example: leicd0,true,-800,300,-2300,-1865,-2000,-2000,0,10,pass example: leicd1,true,-800...

  • Page 270

    Reading test results data low energy tests mt8852b programming manual pn: 13000-00110 rev. V 15-47 ble modulation characteristics test results (mt8852b-043 and units with option 27 only) summary results (note variations when measuring blr8 packets.) extended results (note variations when measuring b...

  • Page 271

    Low energy tests reading test results data 15-48 pn: 13000-00110 rev. V mt8852b programming manual delta f2 average floating point e.G. 2.253e+005 (omitted for blr8) delta f2avg / delta f1avg floating point e.G. 0.850 (omitted for blr8) delta f2 max failed integer e.G. 0 (delta f1 max failed for blr...

  • Page 275

    Low energy tests reading test results data 15-52 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 276

    Mt8852b programming manual pn: 13000-00110 rev. V 16-1 chapter 16 — ble measurement this chapter provides details of the bluetooth low energy measurement commands and associated parameters. The commands in this chapter are listed in alphabetical order. Abortcap abort the ble measurement capture if t...

  • Page 277

    Ble measurement 16-2 pn: 13000-00110 rev. V mt8852b programming manual lescptcfg (configure all measurements in a script in parallel) set command format lescptcfglepkttype remarks this command allows all low energy measurements in a script to be configured in parallel. It is when testing bluetooth 5...

  • Page 278

    Ble measurement mt8852b programming manual pn: 13000-00110 rev. V 16-3 measblecap (capture and make ble tx measurement) set command format measblecap remarks this command enables the mt8852b to capture the ble test packet based on the trigger set up using the cfgblecap command. When the packet is ca...

  • Page 279

    Ble measurement 16-4 pn: 13000-00110 rev. V mt8852b programming manual measblecapx (capture and make ble tx measurement - extended) set command format measblecapx remarks this command enables the mt8852b to capture the ble test packet based on the trigger set up using the cfgblecap command. When the...

  • Page 280

    Ble measurement mt8852b programming manual pn: 13000-00110 rev. V 16-5 setblecaptyp (set the capture type to ble, 2le or blr) set command format setblecaptyp remarks this command configures the mt8852b to capture a low energy packet type. Ble 1 msym/s uncoded 2le 2 msym/s blr 1 msym/s coded (s=2 or ...

  • Page 281: Example Ble Measurement

    Ble measurement 16-6 pn: 13000-00110 rev. V mt8852b programming manual example ble measurement an example of the processes required to perform a ble tx measurement is given below. 1. Configure the dut to transmit ble test packets with the required payload. 2. Set the capture type to ble, 2le or blr:...

  • Page 282

    Mt8852b programming manual pn: 13000-00110 rev. V 17-1 chapter 17 — auxiliary commands this chapter provides details of the auxiliary commands allowed over the gpib interface to help development and demonstrations. The commands are detailed in alphabetical order as shown in the list below. Connect s...

  • Page 283

    Auxiliary commands 17-2 pn: 13000-00110 rev. V mt8852b programming manual connect (connect to eut address) this command is used to connect to the eut address listed in the mt8852b. This command does not request the eut features. Do not use this command to make a connection before running a normal te...

  • Page 284

    Auxiliary commands mt8852b programming manual pn: 13000-00110 rev. V 17-3 connpkt (connection packet control) contime? (connection time) (option 15 required) set command format connpkt this is a ‘binary string’ where a ‘1’ indicates that the packet type shall be used and a ‘0’ that the packet type w...

  • Page 285

    Auxiliary commands 17-4 pn: 13000-00110 rev. V mt8852b programming manual disconnect (disconnect from device) this command disconnects any existing acl connection. If an acl connection does not exist, an execution error is indicated. This command invalidated the eut address when it is anything other...

  • Page 286

    Auxiliary commands mt8852b programming manual pn: 13000-00110 rev. V 17-5 eutvendcmd (send a vendor-specific command to eut) set command format eutvendcmd,, remarks this command writes the defined vendor-specific hci command to the eut via the control port on the mt8852b. The vendor-specific event r...

  • Page 287

    Auxiliary commands 17-6 pn: 13000-00110 rev. V mt8852b programming manual example if the response from a successful vendor-specific command was a vendor- specific event or a command-complete event, and the event was 12 bytes long, the reply would be: eutvendevent,0,12,0e0501abfc00 if the response fr...

  • Page 288

    Auxiliary commands mt8852b programming manual pn: 13000-00110 rev. V 17-7 fixedoff (set fixed offset value) this command is used to set or read the fixed path offset value applied during testing when the path offset mode is set to fixed. Geteutfeat (obtain supported features from eut) this command i...

  • Page 289

    Auxiliary commands 17-8 pn: 13000-00110 rev. V mt8852b programming manual inqrsp? (obtain the results of an inquiry) this command is used after an inquiry or inqcancel command to obtain the results of the inquiry. Inquiry (perform an inquiry) this command performs an inquiry based on the internal in...

  • Page 290

    Auxiliary commands mt8852b programming manual pn: 13000-00110 rev. V 17-9 loopback (perform a loopback test control sequence) this command allows a single loopback test control sequence to be requested. The command is rejected with an execution error if an acl connection does not already exist or if...

  • Page 291

    Auxiliary commands 17-10 pn: 13000-00110 rev. V mt8852b programming manual pathdel (delete an entry from a path loss table) this command is used to delete an entry from a path loss table. If there is no entry for the given channel number in the table specified, a gpib execution error is returned. Pa...

  • Page 292

    Auxiliary commands mt8852b programming manual pn: 13000-00110 rev. V 17-11 pathoff (set path offset mode) this command is used to set up the user path offset mode for the single slot and multi slot sensitivity tests. This is the path loss offset that is added to the transmitted power. Pathrd (read a...

  • Page 293

    Auxiliary commands 17-12 pn: 13000-00110 rev. V mt8852b programming manual pathtbl (set path offset table) this command selects which of the path offset tables is applied to the script. Pathtblclr (clear a user path table) this command can be used to clear one of the user path loss tables. Testmode ...

  • Page 294

    Auxiliary commands mt8852b programming manual pn: 13000-00110 rev. V 17-13 tstdelay (test control delay) each device reacts to a test control command at a different speed. This command allows a delay to be set up for each script to allow for the time taken to change to the test control parameters. T...

  • Page 295

    Auxiliary commands 17-14 pn: 13000-00110 rev. V mt8852b programming manual txtest (perform a tx test control sequence) this command allows a single tx test control sequence to be requested. The command is rejected with an execution error if an acl connection does not already exist (see connect comma...

  • Page 296: Format

    Mt8852b programming manual pn: 13000-00110 rev. V a-1 appendix a — supported features format a-1 eut feature format this table details the eut feature format mask as defined in the bt specification. Refer to commands geteutfeat and eutfeat for details on how to obtain eut features information. Byte ...

  • Page 297

    Eut feature format a-2 pn: 13000-00110 rev. V mt8852b programming manual 3 0 reserved 1 edr acl 2mbps mode 2 edr acl 3mbps mode 3 enhanced inquiry scan 4 interlaced inquiry scan 5 interlaced page scan 6 rssi with inquiry results 7 extended sco link (ev3 packets) 4 0 ev4 packets 1 ev5 packets 2 reser...

  • Page 298: B-1

    Mt8852b programming manual pn: 13000-00110 rev. V b-1 appendix b — gpib pc card set-up the following gpib driver configuration setup is recommended for reliable gpib communication with the mt8852b. The set up is expressed in the terms used by the national instruments gpib isa and pci cards and drive...

  • Page 299

    Gpib device template b-2 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 300: C-1

    Mt8852b programming manual pn: 13000-00110 rev. V c-1 appendix c — script default settings c-1 script 1 default settings table c-1. Script 1 default settings hopping hopping test mode frequency test type packet type number of packets output power on any — loopback dh1 100 init carrier on any — loopb...

  • Page 301: C-2

    Script 2 default settings c-2 pn: 13000-00110 rev. V mt8852b programming manual c-2 script 2 default settings table c-2. Script 2 default settings hopping hopping test mode frequency test type packet type number of packets output power on defined l,m,h loopback longest 10 power control off defined l...

  • Page 302: C-3

    Scripts 3 to 10 default settings mt8852b programming manual pn: 13000-00110 rev. V c-3 c-3 scripts 3 to 10 default settings table c-3. Scripts 3 to 10 default settings hopping hopping test mode frequency test type packet type number of packets output power on defined l,m,h loopback longest 10 power ...

  • Page 303

    Scripts 3 to 10 default settings c-4 pn: 13000-00110 rev. V mt8852b programming manual.

  • Page 304: Index

    A to e mt8852b programming manual pn: 13000-00110 rev. V index-1 index a abort command . . . . . . . . . . . . . . . . . . 14-1 abortcap command . . . . . . . . . . . . . . 16-1 acm command . . . . . . . . . . . . . . . . . . . . . 8-2 afh command . . . . . . . . . . . . . . . . . . . . . 8-2 afhcfg...

  • Page 305

    F to l index-2 pn: 13000-00110 rev. V mt8852b programming manual errlst command . . . . . . . . . . . . . . . . . . 4-2 ese command . . . . . . . . . . . . . . . . . . . . . . 3-3 esiggen command . . . . . . . . . . . . . . . . . 9-6 esr command . . . . . . . . . . . . . . . . . . . . . . 3-4 ete co...

  • Page 306

    M to r mt8852b programming manual pn: 13000-00110 rev. V index-3 lemicfg command . . . . . . . . . . . . . . 10-39 lempcfg command . . . . . . . . . . . . . . 10-46 leopcfg command . . . . . . . . . . . . . . 10-34 lepktgen command . . . . . . . . . . . . . . . 9-4 lepktlen command . . . . . . . . ....

  • Page 307

    S to w index-4 pn: 13000-00110 rev. V mt8852b programming manual results summary . . . . . . . . . . . . . . . . . . . 15-2 rnum command . . . . . . . . . . . . . . . . . . 5-20 rs232 baud rate command . . . . . . . . . . . 5-9 rs232 commands . . . . . . . . . . . . . . . . . . 2-12 rsmode command ....

  • Page 308

    Australia anritsu pty. Ltd. Unit 21, 21-35 ricketts road mount waverley victoria 3168 australia telephone: +61-3-9558-8177 fax: +61-3-9558-8255 brazil anritsu eletronica ltda. Praça amadeu amaral, 27 - 1 andar 01327-010-bela vista-são paulo-sp brazil telephone: +55-11-3283-2511 fax: +55-11-3288-6940...

  • Page 309

    Http://www.Anritsu.Com anritsu prints on recycled paper with vegetable soybean oil ink..