ANTAIRA LNX-800N User manual

Manual is about: 8-Port 10/100TX SNMP Managed Industrial Ethernet Switch with Redundant Ring

Summary of LNX-800N

  • Page 1

    8-port 10/100tx snmp managed industrial ethernet switch with redundant ring user manual.

  • Page 2: Fcc Warning

    Fcc warning this equipment has been tested and found to comply with the limits for a class-a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and ...

  • Page 3: Content

    Content introduction ................................................................ 1 features ................................................................... 1 package contents .................................................... 2 hardware description ...........................................

  • Page 4

    Wall mount plate mounting .................................... 14 hardware installation ............................................... 15 network application ................................................ 16 redundant ring application ................................... 16 coupling ring applicati...

  • Page 5

    Power alarm configuration ............................................. 35 ip configuration ...................................................... 35 sntp configuration ............................................... 36 ip security .............................................................. 39 rs...

  • Page 6: Introduction

    1 introduction the 8-port 10/100tx snmp managed industrial ethernet switch with redundant ring is a cost- effective solution and meets the high reliability requirements demanded by industrial applications. The 8-port 10/100tx snmp managed industrial ethernet switch with redundant ring can be easily ...

  • Page 7: Package Contents

    2  simple network time protocol supported  management ip security  tftp firmware update and system configuration restore and backup  1mbits embedded memory  2k mac address table s nmp, web management, rmon supported package contents please refer to the package content list below to verify them ...

  • Page 8: Hardware Description

    3 hardware description in this paragraph, we will introduce the industrial switch ’s hardware spec, port, cabling information, and wiring installation. Physical dimension 8-port 10/100tx snmp managed industrial ethernet switch with redundant ring dimension (w x h x d) is 54mm x 135mm x 105mm front p...

  • Page 9: Bottom View

    4 reset button the reset button provides user a quick and easy way to restart and set the configuration back to default value.  restart: press the button for 2 seconds and release.  set to factory default value: press the button for 5 seconds and release. The switch will set all configurations bac...

  • Page 10

    5 dip switch no status description 1 off disable port 1 alarm on enable port 1 alarm. If the port ’s link fails, the fault led will light up. 2 off disable port2 alarm on enable port 2 alarm. If the port ’s link fails, the fault led will light up. 3 off disable port3 alarm on enable por3 t alarm. If...

  • Page 11: Led Indicators

    6 8 off disable port8 alarm on enable port8 alarm. If the port ’s link fails, the fault led will light up. 9 off disable the ring master function. On enable the switch as the ring master in the redundant ring group. [note] 1. When port alarm function is enabled, the fault led will on and alarm relay...

  • Page 12: Ports

    7 off no power failure or utp port failure or fiber port failure occurs r. M. (ring master) green the industrial switch is the master of redundant ring group. Off the industrial switch is not a ring master in redundant ring group. Lnk/act (port 7 & 8) green the port is linking. Blinks the port is tr...

  • Page 13

    8  rj-45 pin assignments pin number assignment 1 tx+ 2 tx- 3 rx+ 6 rx- [note] “+” and “-” signs represent the polarity of the wires that make up each wire pair. All ports on this industrial switch support automatic mdi/mdi-x operation, you can use straight-through cables (see figure below) for all ...

  • Page 14: Cabling

    9 cross over cable schematic cabling use four twisted-pair, category 5 cabling for rj-45 port connection. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long..

  • Page 15: Wiring The Power Inputs

    10 wiring the power inputs please follow below steps to insert the power wire. [note] the wire range of terminal block is from 12~ 24 awg. V- v+ v- v+ 1. Insert the positive and negative wires into the v+ and v- connector on the terminal block connector. 2. To tighten the wire-clamp screws for preve...

  • Page 16

    11 wiring the fault alarm contact the fault alarm contact is in the middle of terminal block connector as below figure shows. By inserting the wires and set the dip switch at “on” status, it will detect when power is failure or port link failure and form a closed circuit. And, the following figure s...

  • Page 17: Mounting Installation

    12 mounting installation din-rail mounting the din-rail is screwed on the industrial switch when out of factory. If the din-rail is not screwed on the industrial switch, please see the following figure to screw the din-rail on the switch. Follow the below steps to hang the industrial switch. Use the...

  • Page 18

    13 1. First, insert the top of din-rail into the track. 2. Then, lightly push the din-rail into the track. 3. Check the din-rail is tightly on the track. 4. To remove the industrial switch from the track, reverse steps above..

  • Page 19: Wall Mount Plate Mounting

    14 wall mount plate mounting follow the below steps to mount the industrial switch with wall mount plate. 1. Remove the din-rail from the industrial switch; loose the screws to remove the din-rail. 2. Place the wall mount plate on the rear panel of the industrial switch. 3. Use the screws to screw t...

  • Page 20: Hardware Installation

    15 hardware installation in this paragraph, it will describe how to install the 8-port 10/100tx snmp managed industrial ethernet switch with redundant ring and the installation points for attention. 1. Unpack the industrial switch. 2. Check the din-rail is screwed on the industrial switch. If the di...

  • Page 21: Network Application

    16 network application this chapter provides some sample applications to help user to have more actual idea of industrial switch function application. A sample application of the industrial switch as below: redundant ring application the industrial switch supports the redundant ring protocol that ca...

  • Page 22: Coupling Ring Application

    17 coupling ring application in the network, it may have more than one redundant ring group. By using the coupling ring function can connect each redundant ring for the redundant backup. It can ensure the transmissions between two ring groups will no failure. A sample of coupling ring application fi...

  • Page 23: Dual Homing Application

    18 dual homing application dual homing function is to prevent the connection lose between redundant ring group and upper level/core switch. The dual homing function only work when the redundant ring function is active. The maximum dual homing port is one in a redundant ring group. [note] in dual hom...

  • Page 24: Web-Based Management

    19 web-based management this section introduces the configuration and functions of the web-based management. The following configuration steps are based on the firmware version 1.06. About web-based management on cpu board of the switch there is an embedded html web site residing in flash memory, wh...

  • Page 25: System Login

    20  default gateway: 192.168.1.254  user name: admin  password: admin system login 1. Launch the internet explorer on the pc. 2. Key in “http:// “+” the ip address of the switch”, and then press “enter”. 3. The login screen will appear right after. 4. Key in the user name and password. The defaul...

  • Page 26: Port Status

    21 port status display every port status which depended on user’s setting and the negotiation result.  port: the port number  type: the speed mode, ex: 100tx = 100mbps  link: “down” means “no link”. “up” is for “link”  state: d isplay port statuses “disable” or “enable”. “unlink” will be treated...

  • Page 27: Port Statistics

    22 port information interface port statistics display the current port statistic information. Click clear button to clean all counts. Port statistics interface.

  • Page 28: Port Control

    23 port control modifying the port status 1. Select the port by scroll the port column 2. State: disable or enable control of his port 3. Negotiation: set auto negotiation mode is auto, nway (specify the speed/duplex on this port and enable auto-negotiation), or force 4. Speed: set the speed of the ...

  • Page 29: Port Mirroring

    24 bytes.  system location: assign the switch physical location. The maximum length is 64 bytes.  system description: display the description of switch. Read only cannot be modified.  firmware version: display the switch’s firmware version.  kernel version: display the kernel software version. ...

  • Page 30: Vlan Configuration

    25 2. Analysis port: the mirror port will receive all monitored port traffic. The mirror port can connect with the lan analyzer or netxray. 3. Monitor port: the ports which user wants to monitor. All monitor port traffic will be copied to mirror port. Maximum 7 monitor ports can be selected in one s...

  • Page 31

    26 network devices to another layer 2 switch. However, all the network devices are still plugged into the same switch physically. The industrial switch supports port-based and 802.1q (tagged-based) vlan. In the default configuration, vlan operation mode default is “disable”. Vlan configuration inter...

  • Page 32

    27 vlan – portbase interface 1. Click add to add a new vlan group. The maximum vlan group is up to 64 vlan groups 2. Enter the vlan name, group id and group the members of vlan group 3. Click apply.

  • Page 33

    28 vlan —portbase add interface 4. The vlan group list will display right after. 5. Click next page to view other vlan groups. 6. Use delete button to delete unwanted vlan. 7. Use edit button to modify existing vlan group. [note] remember to execute the “save configuration” action, otherwise the new...

  • Page 34

    29 all ports on the switch belong to default vlan, vid is 1. The default vlan can’t be deleting. The maximum vlan group is up to 64 vlan groups. 802.1q vlan interface  basic 1. Click add button 2. Management vlan id: it is used for remote management security. In fact, it can remote management throu...

  • Page 35

    30 management vlan id, it still has the right to remote management the switch. 3. Group name: assign a name for the new vlan 4. Vlan id: fill in a vlan id (2~ 4094). The default is 1 5. Select ports from the ports list, and then, click add to group the port as a vlan group 802.1q vlan –add interface...

  • Page 36

    31 7. Set the outgoing frames are vlan-tagged frames or untagged, and then click apply  tag: outgoing frames with vlan-tagged  untag: outgoing frames without vlan-tagged  port vid: configure port vid settings 1. Port vlan id: enter the port vlan id 2. Click apply 3. To reset to default value, cli...

  • Page 37: Alert

    32 802.1q vlan – port vlan id interface [note] remember to execute the “save configuration” action, otherwise the new configuration will lose when the switch power off. Alert there are three kinds of alert – e-mail, event, and power alarm. You can configure each alert function, as you needed. Email ...

  • Page 38

    33 2. Smtp server ip address: set up the mail server ip address 3. Authentication: mark the check box to enable and configure the email account and password for authentication  mail account: set up the email account to receive the alert. Ex: johnadmin@123.Com . The email account must exist on the m...

  • Page 39

    34  system event selection: 4 selections – device cold start, power status, snmp authentication failure, and redundant ring topology changes. Mark the checkbox to select the event. When selected events occur, the system will sent out the alerting.  device cold start: when the device executes cold ...

  • Page 40: Ip Configuration

    35 event configuration interface power alarm configuration power alarm function enables the relay alarm action. Without enabling power alarm function, the relay alarm action will not work even the relay alarm is set. Mark the check box and click apply button. Power alarm interface ip configuration c...

  • Page 41: Sntp Configuration

    36 apply the new ip settings.  dhcp client: enable or disable the dhcp client function. When dhcp client function is enabling, the industrial switch will be assigned the ip address from the network dhcp server. The default ip address will be replace by the dhcp server assigned ip address. After cli...

  • Page 42

    37 1. Sntp client: enable or disable sntp function to get the time from the sntp server 2. Daylight saving time: enable or disable daylight saving time function. When daylight saving time is enabling, user need to configure the daylight saving time period 3. Utc timezone: set the switch location tim...

  • Page 43

    38 cet - central european fwt - french winter met - middle european mewt - middle european winter swt - swedish winter +1 hour 1 pm eet - eastern european, ussr zone 1 +2 hours 2 pm bt - baghdad, ussr zone 2 +3 hours 3 pm zp4 - ussr zone 3 +4 hours 4 pm zp5 - ussr zone 4 +5 hours 5 pm zp6 - ussr zon...

  • Page 44: Ip Security

    39 6. Daylight saving period: configure the daylight saving time period 7. Daylight saving offset (mins): configure the offset value 8. Click apply [note] remember to execute the “save configuration” action, otherwise the new configuration will lose when the switch power off. Sntp configuration ip s...

  • Page 45: Rstp Configuration

    40 [note] remember to execute the “save configuration” action, otherwise the new configuration will lose when the switch power off. Ip security interface rstp configuration the rapid spanning tree protocol (rstp) is an evolution of the spanning tree protocol and provides for faster spanning tree con...

  • Page 46

    41 parameters  priority (0-61440): a value used to identify the root bridge. The bridge with the lowest value has the highest priority and is selected as the root. If the values change, user has to reboot the switch. The value must be multiple of 4096 according to the protocol standard rule.  max ...

  • Page 47

    42 rstp – system configuration interface per port configuration configuring the path cost and priority of every port 1. Select the port in port column 2. Path cost: the cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200000000. 3. Pr...

  • Page 48

    43 p2p disabling. 5. Admin edge: the port directly connected to end stations cannot create bridging loop in the network. To configure the port as an edge port, set the port to “true” status. 6. Admin non stp: the port includes the stp mathematic calculation. True is not including stp mathematic calc...

  • Page 49: Redundant Ring

    44 redundant ring redundant ring provides a faster redundant recovery than spanning tree topology. The action is similar with stp or rstp, but the algorithms not the same. In the redundant ring topology, every switch should enable redundant ring function and assign two member ports in the ring. Only...

  • Page 50

    45 level/core switch. Enable redundant ring: to enable the redundant ring function. Marking the check box to enable the redundant ring function.  1 st & 2 nd working ports: assign two ports as the member ports. One port will be working port and one port will be the backup port. The system will auto...

  • Page 51: Qos Configuration

    46 time. 2. Remember to execute the “save configuration” action, otherwise the new configuration will lose when the switch power off. Qos configuration configure qos setting of the every port.  oos policy: select the qos policy rule  using the 8,4,2,1 weight fair queue scheme: the switch will foll...

  • Page 52

    47 when the packet received by port 1, the system will check the tos value of the received ip packet. If the tos value of received ip packet is 25(priority = high), and then the packet priority will have highest priority. [note] qos and rate control cannot be existed at the same time. Qos configurat...

  • Page 53: Igmp

    48 igmp the internet group management protocol (igmp) is an internal protocol of the internet protocol (ip) suite. Ip manages multicast traffic by using switches, routers, and hosts that support igmp. Enabling igmp allows the ports to detect igmp queries and report packets and manage ip multicast tr...

  • Page 54: Snmp Configuration

    49 igmp snooping interface snmp configuration the snmp is a protocol that governs the transfer of information between management and agent. The switch supports snmp v1. Define management stations as trap managers and to enter snmp community strings. Also, define a name, location, and contact person ...

  • Page 55

    50 community strings community strings serve as password for mib read or write. 1. Strings: fill the name of string 2. Ro: read only. Enables requests accompanied by this string to display mib-object information 3. Rw: read write. Enables requests accompanied by this string to display mib-object inf...

  • Page 56: Security Manager

    51 snmp management interface security manager changing web management login user name and password for the management security issue 1. User name: key in the new user name. The default is “admin” 2. Password: key in the new password. The default is “admin” 3. Confirm password: re-enter the new passw...

  • Page 57: Configuration Backup

    52 security manager interface configuration backup restore the backup configuration back to the industrial and backup the switch configuration to tftp server. Tftp restore configuration the restore flash rom value can be restored from tftp server, but the backup image has to be on the tftp server. T...

  • Page 58: Tftp Update Firmware

    53 tftp backup configuration saving current flash rom value from the industrial switch to the tftp server, then go to the tftp restore configuration page to restore the image value back to the industrial switch. 1. Tftp server ip address: fill in the tftp server ip 2. Backup file name: fill the file...

  • Page 59: Factory Default

    54 tftp update firmware interface factory default reset switch to default configuration, except the ip address, subnet mask, default gateway, username, and password will remain as user had been configured. Click default button to reset switch to default setting. Factory default interface save config...

  • Page 60: System Reboot

    55 system reboot reboot the switch in software reset. Click reboot button to reboot the switch. System reboot interface rate control set up every port ’s bandwidth rate and packet limitation type.  limit packet type: select the packet type that wants to filter. The packet types have all type packet...

  • Page 61: System Log

    56 [note] 1. Remember to execute the “save configuration” action, otherwise the new configuration will lose when the switch power off. 2. Qos and rate control cannot be existed at the same. Rate control interface system log set up system log events and view the system log events. System log configur...

  • Page 62

    57  click apply button to apply the configuration system log configuration interface event configuration select the system log events. When selected events occur, the system will send out the log information. Also, per port log events can be selected.  system event selection: 4 selections – device...

  • Page 63

    58 system will produce a log message  power status: when the device power status has changed, the system will produce a log message  snmp authentication failure: when the snmp authentication fails, the system will produce a log message  redundant ring topology change: when the redundant ring topo...

  • Page 64: Troubles Shooting

    59 troubles shooting  verify that is using the right power cord/adapter (dc 12-48v), please don’t use the power adapter with dc output bigger than 48v, or it will burn this switch down.  select the proper utp cable to construct your network. Please check that you are using the right cable. Use uns...

  • Page 65: Technical Specification

    60 technical specification the 8-port 10/100tx snmp managed industrial ethernet switch with redundant ring technical specifications are as follows. Standard ieee 802.3 10base-t ethernet ieee 802.3u 100base-tx fast ethernet ieee802.3x flow control and back-pressure ieee802.1d spanning tree / ieee802....

  • Page 66

    61 packet throughput ability 2.38mpps @64bytes (8tx) led per port: link/activity (green), full duplex/collision (yellow) per unit: power (green) power 1 (green) power 2 (green) fault (yellow) master (green) network cable 10base-t: 2-pair utp/stp cat. 3, 4, 5 cable eia/tia-568 100-ohm (100m) 100base-...

  • Page 67

    62 snmp mib rfc 1213 mibii rfc 1493 bridge mib rmon rfc 1757 rfc 2674 vlan mib rfc 1643 ethernet like mib rfc1215 trap mib igmp mib. Private mib for switch information, redundant ring, port alarm, tftp firmware upgrade, reset, port mirror, ip security snmp trap up to 3 trap stations cold start, port...

  • Page 68

    63 spanning tree ieee802.1d spanning tree ieee802.1w rapid spanning tree igmp igmp v1 and query mode up to 256 groups sntp simple network time protocol smtp simple mail transfer protocol system event log 1000 event log entries management ip security ip address security to prevents unauthorized intru...

  • Page 69

    64 install provide din rail kit and wall mount ear for wall mount or din-type cabinet install alarm provides one relay output for port breakdown, power fail and provide dipswitch to mask link down port. Alarm relay current carry ability: 1a @ dc24v bandwidth control  support ingress packet filter a...

  • Page 70

    65 storage temperature -40℃ to 85℃ case dimension ip-30, 54 mm (w) x 135 mm (h) x 105mm (d) emi fcc class a, ce en61000-4-2 (esd), ce en61000-4-3 (rs), ce en61000-4-4 (eft), ce en61000-4-5 (surge), ce en61000-4-6 (cs), ce en61000-4-8, ce en61000-4-11, ce en61000-4-12, ce en61000-6-2, ce en61000-6-4 ...