2) Mount the thermostat
Push the excess wires back
inside the electrical box.
Secure the thermostat to the
electrical box using the provided
screws.
Insert the screws through either
the right or left pair of mounting
holes on the thermostat.
3) Complete the installation
NOTE: If there is a protective film or sticker on the thermostat’s
screen, peel it off.
Apply power to the heating system. Verify the installation by checking
that the heater can be turned On and Off by raising and lowering the
setpoint using the
Up
and
Down
buttons.
WARNING: Keep the thermostat's air vents clean and free from
obstructions.
The thermostat normally displays the room (measured) temperature.
•
To view the set temperature (setpoint), press the
Up
or
Down
button once.
•
To change the setpoint, press the
Up
or
Down
button until the
desired setpoint is displayed.
•
The screen is backlit for 10 seconds when any button is pressed.
The factory settings are inside the shaded cells of the following table.
WARNING: The clock loses its setting whenever you change the
thermostat’s configuration.
Temperature display
To change the temperature display between °C and °F:
n
Open the thermostat’s door.
o
Press and hold the
Day
button.
p
Insert a pointed object (e.g., paperclip) in the reset opening.
Remove it when the thermostat’s screen becomes blank.
q
Wait one second and release the
Day
button.
Time display
To switch between the 12-hour format and the 24-hour format:
n
Open the thermostat’s door.
o
Press and hold the
Hour
button.
p
Insert a pointed object (e.g., paperclip) in the reset opening.
Remove it when the thermostat’s screen becomes blank.
q
Wait one second and release the
Hour
button.
Control type
Use proportional control (default setting) in most cases as it pro-
vides better temperature control.
Use conventional control if you have a fan-forced heater.
Fan
is displayed when conventional control is selected. To switch
between the two types of control:
n
Open the thermostat’s door.
o
Press and hold the
Min
button.
p
Insert a pointed object (e.g., paperclip) in the reset opening.
Remove it when the thermostat’s screen becomes blank.
q
Wait one second and release the
Min
button.
The clock must be set when
Time
flashes on the
screen.
n
Open the thermostat’s door.
o
Press the
Day
button to set the day.
p
Use the
Hour
and
Min
buttons to set the clock.
q
Press the
button to exit.
The thermostat has three modes of operation:
Automatic mode
To use the Automatic mode, press the Mode button
until
Auto
is selected (outlined) on the screen. The cur-
rent period number will appear.
In this mode, the thermostat automatically adjust its
temperature setpoint according to the period of the day
(wake up, leave for work, return home and sleep).
You can program up to 4 periods in a day. You can set 2 different
programs: one for the weekdays (Monday to Friday) and another one
for the weekend (Saturday and Sunday).
p
Temperature Display and Setting
3.
q
Configuration
4.
Temperature display
°C
°F
Time display
24 h
12 h
Temperature control
Proportional
(15-second cycles)
Conventional
(± 0.5°C deadband)
r
Clock and Day Setting
5.
s
Modes of Operation
6.
400-104-004-D (TH104PLUS) ENG.fm Page 2 Tuesday, January 29, 2008 4:21 PM