B&B Electronics Elinx EIR418-2SFP-T User Manual

Manual is about: Industrial

Summary of Elinx EIR418-2SFP-T

  • Page 1

    Manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com e e i i r r 4 4 1 1 8 8 - - 2 2 s s f f p p - - t t u u s s e e r r m m a a n n u u a a l l.

  • Page 2

    I manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com e e i i r r 4 4 1 1 8 8 - - 2 2 s s f f p p - - t t d d o o c c u u m m e e n n t t a a t t i i o o n n n n u u m m b b e e r r : : e e i i r r 4 4 1 1 8 8 - - 2 2 s s f f p p - - t t - - 0 0 1 1 0 0 9 9 m m u u s ...

  • Page 3: Table of Contents

    Table of contents ii manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com table of contents 1. Introduction ..................................................................................................................... 1 features....................................

  • Page 4: Introduction

    Introduction 1 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com introduction the eir418-2sfp-t is an industrial din mount, unmanaged 18 port ethernet switch with gigabit capability. It has (16) 10/100 copper ethernet ports and (2) gigabit combo ports that support c...

  • Page 5: Package Contents

    Introduction 2 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com package contents • (1) eir418-2sfp-t, 18 port gigabit industrial ethernet switch • (1) quick start guide • (1) cd rom with user manual • (2) wall mounting bracket and screws.

  • Page 6: Hardware Description

    Hardware description 3 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com hardware description physical dimension (w x d x h) is 72mm x 105mm x 152mm (2.8 x 4.1 x 6.0 inches) front panel the front panel of the eir418-2sfp-t is shown below..

  • Page 7: Top View

    Hardware description 4 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com top view the top panel view of the eir418-2sfp-t is equipped with one terminal block connector that consists of two 12 to 48 vdc power inputs and the fault alarm output. Led indicators led stat...

  • Page 8

    Hardware description 5 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com green (upper led) connected to network blinking (upper led) networking is active off (upper led) not connected to network yellow (lower led) ethernet port full duplex blinking (lower led) colli...

  • Page 9: Ports

    Hardware description 6 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com ports rj-45 ports: eight rj-45 ports auto-sense for 10, 100 mbps while two ports auto-sense for 10, 100 or 1000 mbps device connections. The auto mdi/mdix feature allows connections to switches...

  • Page 10

    Hardware description 7 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com straight through cable schematic cross over cable schematic • 2 gigabit copper/sfp (mini-gbic) combo port: the eir418-2sfp-t has two auto-detect giga ports—copper/fiber combo ports. The gigabit...

  • Page 11

    Hardware description 8 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com port will link down. If a 100m sfp transceiver is inserted into the sfp cage the copper combo port will link down regardless of the connection status of the remote device..

  • Page 12

    Hardware description 9 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com.

  • Page 13

    Hardware description 10 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com to connect the transceiver and fiber cable, follow the steps shown below. (note: sfp modules typically terminate with an lc fiber connector) first, insert the sfp transceiver into the sfp modu...

  • Page 14

    Hardware description 11 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com second, insert the fiber cable into the transceiver. Lc connector to the transceiver to remove the lc connector and sfp transceiver, follow the steps below: first, press the upper side of the ...

  • Page 15: Cabling

    Hardware description 12 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com second, swivel the metal latch away from the switch and pull the transceiver out. Pull out from the sfp module cabling use unshielded twisted-pair (utp) or shielded twisted-pair (stp) cable. 1...

  • Page 16

    Hardware description 13 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com 2. Tighten the wire-clamp screws for prevent the wires from becoming loose. Wiring the fault alarm contact the fault alarm contact is in the middle of the terminal block connector as shown below. If one of the ...

  • Page 17: Mounting Installation

    Mounting installation 14 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com mounting installation din-rail mounting the din rail clip comes screwed on to the switch, from the factory. If the din rail clip is not screwed on the switch, please see the following figure ...

  • Page 18

    Mounting installation 15 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com 3. First, insert the top of din rail clip onto the piece of the din rail track. 4. Then, lightly push the bottom of the switch so it can snap the rest of the way onto the din rail track. 5. C...

  • Page 19

    Mounting installation 16 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com • pulling slowly at the bottom of the switch will bring the switch out so that the switch can now be carefully lifted off the din rail track. Wall or panel mount plate mounting follow the steps below to mount ...

  • Page 20: Hardware Installation

    Hardware installation 17 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com hardware installation installation steps 1. Unpack the switch. 2. Check if the din rail clip is screwed on the industrial switch or not. If the din rail clip is not screwed onto switch, pleas...

  • Page 21: Network Application

    Network application 18 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com network application the diagram below shows a typical switch installation for the eir418-2sfp-t..

  • Page 22: Troubleshooting

    Troubleshooting 19 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com troubleshooting • verify that you are using a power supply ranging from 12 to 48vdc. Applying more than 48vdc could cause damage to the switch. • be sure the proper cable is used in your network. R...

  • Page 23: Technical Specification

    Technical specification 20 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com technical specification standard ieee 802.3 10base-t ieee 802.3u 100base-tx ieee 802.3ab 1000base-t ieee 802.3z gigabit fiber ieee 802.3x flow control and back-pressure protocol csma/cd tra...

  • Page 24

    Technical specification 21 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com optical cable „ multi-mode: 50/125um or 62.5/125um „ single mode: 9/125um back-plane 7.2gbps packet throughput ability 10.7mpps at 64bytes power supply 12 to 48 vdc redundant power with pol...

  • Page 25

    Technical specification 22 manual documentation number eir418-2sfp-t – 0109m www.Bb-elec.Com www.Bb-europe.Com ce en61000-4-11 ce en61000-4-12 ce en61000-6-2 ce en61000-6-4 safety ul cul ce/en60950-1 stability testing iec60068-2-32 (free fall) iec60068-2-27 (shock) iec60068-2-6 (vibration).