B&B Electronics IE-Giga-MiniMc Operation Manual

Summary of IE-Giga-MiniMc

  • Page 1

    Ie-giga-minimc operation manual.

  • Page 2

    Ii fcc radio frequency interference statement this equipment has been tested and found to comply with the limits for a class a computing device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operate...

  • Page 3

    Iii table of contents fcc radio frequency interference statement .............................................................. Ii warranty ......................................................................... Error! Bookmark not defined. About the ie-giga-minimc ...................................

  • Page 4

    1 about the ie-giga-minimc the ie-giga-minimc is a 10/100/1000 auto negotiating switching miniature media converter. The fiber port always operates at 1000 mbps full duplex; the copper port auto negotiates the connected device’s speed and duplex mode: 10/100/1000 mbps half duplex; or 10 /100/1000 mb...

  • Page 5

    2 installing the ie-giga-minimc the ie-giga-minimc installs virtually anywhere as a standalone device in locations with extremely limited space. Installation options include: velcro strips din rail mounting with din rail clips a wall mount bracket an ie-powertray/18 for high density applications ins...

  • Page 6

    3 hardware mounting options the ie-giga-minimc can be mounted on a din rail or using wall mount brackets (shown below). Din rail clips (part number 806-39105) and wall mount brackets (part number 895-39229) are available for purchase through an b&b electronics distributor. Din rail clips the din rai...

  • Page 7

    4 powering the ie-giga-minimc ie-giga-minimc supports multiple powering options. • a country-specific ac power adapter (included) • the 4-terminal dc power block • ie-powertray/18 • dual usb cable • ie-power/5v din rail mount power supply led operation each ie-giga-minimc converter includes two leds...

  • Page 8

    5 dc terminal block wiring instructions the ie-giga-minimc can be powered via the dc terminal block. From a power source, connect to any one positive and any one negative terminal on ie-giga- minimc. Connected to chassis note when using stranded wire, the leads must be tinned and equivalent to a 16 ...

  • Page 9

    6 cascading power when installing multiple ie-giga-minimc units on a din rail, connect to one dc input source and then cascade from one dc block to the next, until reaching the maximum electrical current available..

  • Page 10

    7 dc power supply precautions the following precautions should be observed when installing chassis with dc power supplies. 1. Check nameplate ratings to assure there is no overloading of supply circuits that could have an effect on overcurrent protection and supply wiring. 2. When installing 7 to 50...

  • Page 11

    8 specifications ethernet connections • 10/100/1000 baset • auto negotiation • autocross • flow control • 1632 mtu • full line-rate forwarding dc input voltage 7 to 50 vdc on dc terminal block 5 vdc on dc jack ac wall adapter 100 to 240 ±10% vac input, 5 vdc output, 2 a max power tray 18-slot ac for...

  • Page 12

    9 b&b electronics technical support tel: (800) 346-3119 (in the u.S. And canada) monday-friday, 7:00am-7”00pm cst +353 91 792444 (europe) monday through friday 8:00am - 5:00pm gmt fax: (815) 433-5109 e-mail: support@bb-elec.Com web: www.Bb-elec.Com.

  • Page 13

    10 fiber optic cleaning guidelines fiber optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1. Use fiber p...

  • Page 14

    11 electrostatic discharge precautions electrostatic discharge (esd) can cause damage to any product, add-in modules or stand alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products 1. Do not remove unit from its pro...

  • Page 15

    12 safety certifications ul/cul: listed to safety of information technology equipment, including electrical business equipment. Ce: the products described herein comply with the council directive on electromagnetic compatibility (2004/108/ec) and the council directive on electrical equipment designe...

  • Page 16

    13.

  • Page 17

    International headquarters b&b electronics 707 dayton road ottawa, il 61350 usa phone (815)433-5100 — general fax (815) 433-5105 website: www.Bb-elec.Com european headquarters b&b electronics westlink commercial park oranmore, co. Galway, ireland phone +353 91-792444 — fax +353 91-79244s5 website: w...