B+B SmartWorx SEG510-2SFP-T User manual

Manual is about: SE500 Series CLI

Summary of SEG510-2SFP-T

  • Page 1

    Se500 series cli user manual.

  • Page 2

    Ii cli advantech b+b smartworx - americas 707 dayton road ottawa, il 61350 usa phone (815) 433-5100 fax (815) 433-5105 advantech b+b smartworx - european headquarters westlink commercial park oranmore, co. Galway, ireland phone +353 91-792444 fax +353 91-792445 www.Advantech-bb.Com support@advantech...

  • Page 3: Acknowledgements

    Iii cli acknowledgements intel and pentium are trademarks of intel corporation. Microsoft windows and ms-dos are registered trademarks of microsoft corp. All other product names or trademarks are properties of their respective owners. Supported models the user manual is only available for the follow...

  • Page 4: Warnings, Cautions and Notes

    Iv cli technical support and assistance 1. Visit the advantech web site at www.Advantech.Com/support where you can find the lat- est information about the product. 2. Contact your distributor, sales representative, or advantech's customer service center for technical support if you need additional a...

  • Page 5: Contents

    V industrial protocols command line interface ............................................. 1 using the command-line interface ................................................................................................. 1 initially configuring a device .............................................

  • Page 6

    Vi industrial protocols ssh ........................................................................................................................................ 40 http ..................................................................................................................................

  • Page 7: List of Tables

    Vii industrial protocols table 1: supported models .............................................................................................................. Iii table 2: account management commands ..................................................................................... 2 table 3: ...

  • Page 8: Command Line Interface

    1 cli using the command-line interface the advantech ios command-line interface (cli) is the primary user interface used to config- ure, monitor, and maintain advantech devices. The user interface allows you to directly exe- cute cli commands. Note that all cli options are also available via the web...

  • Page 9

    2 cli two levels of account privilege are available, admin (for system administrators), and user (for general users). An admin account is required to add additional accounts and assign account privileges. The following table displays the account management commands used to create and edit admin and ...

  • Page 10: L2 Features

    3 cli to save time and the repetition of entering the same command multiple times, you can use a command alias. An alias can be configured to do anything that can be done at the command line, but an alias cannot move between modes, type in passwords, or perform any interactive functions. Table 3 sho...

  • Page 11

    4 cli description word sys_str_const(sy s_portdesc_str_l en) "> admin exec use "description" com- mand to give the port a name to identify it easily. If description includes space character, please use double quotes to wrap it. This example shows how to modify port descriptions. Switch(config)# inte...

  • Page 12

    5 cli mac address-table aging-time admin exec set the aging time of the address table. Switch(config)# mac address- table aging-time 300 mac address-table static a:b:c:d:e:f vlan 4094> interfaces if_ports admin exec add static addresses to the mac address table. Switch(config)# mac address- table st...

  • Page 13

    6 cli spanning tree table 8: spanning tree function privilege description example show spanning-tree [instance ] user exec show spanning-tree instance information. Switch# show spanning-tree instance 10 show spanning-tree interfaces if_ports [instance ] user exec show spanning-tree instance informat...

  • Page 14

    7 cli no spanning-tree hello- time admin exec restore to default hello- time. Default hello-time is 2. Switch# configure switch(config)# no spanning- tree hello-time switch(config)# exit spanning-tree forward- delay admin exec specify the forward-delay interval (seconds). Switch# configure switch(co...

  • Page 15

    8 cli spanning-tree cost long admin exec specify the stp port cost. In long pathcost method, the range is from 0 to 20000000. (0 = auto) switch# configure switch(config)# interface gi1 switch(config-if)# spanning- tree cost long 200000 switch(config-if)# exit switch(config)# exit spanning-tree cost ...

  • Page 17

    10 cli switchport hybrid pvid admin exec this command configures the hybrid port’s pvid. Use "show interface switchport" command to show configu- ration. Switch(config)# interface giga- bitethernet 1 switch(config-if)# switchport mode hybrid switch(config-if)# switchport hybrid pvid 100 [no] switchp...

  • Page 19

    12 cli link aggregation table 11: link aggregation function privilege description example show lag user exec use "show lag" command to show current lag load balance algorithm and members active/inactive status. This example shows how to show current lag status. Switch# show lag lag load-balance (src...

  • Page 20

    13 cli lacp port-priority 65535> admin exec lacp port priority is used for two connected dut to select aggregation ports. Lower port priority value has higher priority. The port with higher priority will be selected into lag first. Use "show running-config" command to show configu- ration. This exam...

  • Page 22

    15 cli show lldp interfaces if_nmlports neigh- bor user exec display the neighbor's lldp information in speci- fied ports. Switch# show lldp interfaces fa5,fa6 neighbor show lldp statistics user exec display the lldp rx/tx statistics. Switch# show lldp statistics show lldp interfaces if_nmlports sta...

  • Page 25

    18 cli no ip unknown-multicast action admin exec when igmp snooping and mld snooping are dis- abled, router port actions cannot be set. Disabling igmp snooping & mld snooping will flood multicast traffic to all mem- bers of the vlan. When the action is a router port flood or drop, it will delete the...

  • Page 26

    19 cli [no] ip igmp snooping vlan vlan-list admin exec "no ip igmp snooping vlan 1" will clear all vlan ip igmp snooping dynamic groups and dynamic router ports, and invalidate any static ip igmp groups with a vlan id of 1. Subse- quently, the dynamic groups and router ports will not be learned via ...

  • Page 28

    21 cli [no] ip mld snooping vlan vlan-list fastleave [no] ip mld snooping vlan vlan-list router learn pim-dvmrp ip mld snooping vlan vlan-list robustness- variable no ip mld snooping vlan vlan-list robustness- variable ip mld snooping vlan vlan-list response- time no ip mld snooping vlan vlan-list r...

  • Page 30: Qos

    23 cli qos rate limit table 19: rate limit function privilege description example show rate-limit user exec display rate-limit infor- mation. Switch# show rate-limit show rate-limit inter- faces if_nmlports user exec display rate-limit infor- mation in specified inter- face. Switch# show rate-limit ...

  • Page 31

    24 cli qos map cos-queue sequence to admin exec configure or show cos to queue map switch# configure switch(config)# qos map cos- queue 6 7 to 1 switch(config)# exit qos map dscp-queue sequence to admin exec configure or show dscp to queue map. Switch# configure switch(config)# qos map dscp- queue 6...

  • Page 34

    27 cli 802.1x table 24: 802.1x function privilege description example show dot1x status user exec show dot1x configuration. Switch# show dot1x [no] dot1x admin exec configure radius server enable/disable. The “dot1x” command glob- ally enables 802.1x ability. The “no dot1x run" com- mand disables th...

  • Page 38

    31 cli [no] ipv6 autoconfig admin exec use "ipv6 autoconfig" com- mand to enable ipv6 auto configuration feature. Use "no ipv6 autoconfig" command to disable ipv6 auto configuration feature. Switch(config)# no ipv6 auto- config ipv6 address x:x::x:x prefix admin exec use "ipv6 address" com- mand to ...

  • Page 41

    34 cli dhcp-server vlan entry vlan low-ip-address a.B.C.D high-ip-address a.B.C.D subnet-mask a.B.C.D gateway a.B.C.D dns a.B.C.D admin exec set allocate ip range, sub- net mask, gateway, dns in specified vlan settings of dhcp server. Switch(config)# dhcp-server vlan entry 2 vlan 12 low-ip- address ...

  • Page 43

    36 cli no clock timezone admin exec use the no form of this command to timezone default setting. Switch(config)# no clock time- zone sntp host hostname [port ] admin exec use the clock set command to set static time. The static time won’t save to configuration file. Switch# clock set 11:03:00 sep 21...

  • Page 44

    37 cli smtp table 38: smtp function privilege description example show smtp user exec view smtp client informa- tion. Smtpc profile-id server-ip a.B.C.D server-port admin exec set smtp server's ip and udp port in profile 1 or 2. Switch(config)# smtpc profile-id 1 server-ip 192.168.1.100 server-port ...

  • Page 45

    38 cli ntp-server timezone acronym hour- offset [minutes 59>] admin exec use the command to set timezone setting. Use the no form of this command to default setting. Switch(config)# ntp-server timezone test +5 no ntp-server timezone admin exec disable timezone setting. Ntp-server summer-time acronym...

  • Page 46

    39 cli rmon history index 65535> interface if_nmlport [buckets ] [interval 3600>] [owner owner] admin exec specify rmon history index. Specify history interface. Specify history bucket time. Specify history record inter- val time. Specify owner. Switch# configure switch(config)# rmon history index 1...

  • Page 47

    40 cli no ip default-gateway admin exec use "no ip default-gate- way" to restore default gate- way address to factory default. Switch(config)# no ip default- gateway ip dns a.B.C.D [a.B.C.D] admin exec use "ip dns" command to modify dns server address. Switch(config)# ip dns 111.111.111.111 no ip dn...

  • Page 49: Diagnostic

    42 cli diagnostic cable diagnostic table 47: cable diagnostic function privilege description example show cable-diag inter- faces if_nmlports user exec display the estimated length of copper cable attached to the ports. Show cable-diag interface all. Display the estimated length of copper cables att...

  • Page 53

    46 cli show flash user exec use "show flash" command to show all files" status which stored in flash. Switch# show flash clear line telnet admin exec terminal length user exec show network-port user exec show network port informa- tion. Switch(config)# no network- port type http [no] network-port ty...