Bacharach MGC200 Instruction

Other manuals for MGC200: Product Data
Manual is about: Bacharach Handheld CO2/CO Monitor Product Data

Summary of MGC200

  • Page 1

    Instruction 0019-9322 mgc 100/200 mgc 100 / 200 instruction 0019-9322 operation & maintenance rev. 2 – may 2010 product leadership • training • service • reliability mgc 2 3.

  • Page 2

    Mgc 100/200 instruction 0019-9322 a instruction 0019-9322 warranty bacharach, inc. Warrants to buyer that at the time of delivery this product will be free from defects in mater ial and manufac ture and will conform substan tially to bacharach inc.’s ap plicable specifi cations. Bacharach’s liabilit...

  • Page 3: Contents

    Instruction 0019-9322 mgc 100/200 i instruction 0019-9322 mgc 100/200 contents 1.0 introduction ................................................................................1 1.1 general .......................................................................................1 1.2 features ...........

  • Page 4

    Mgc 100/200 instruction 0019-9322 notes.

  • Page 5: 1.0 Introduction

    Instruction 0019-9322 mgc 100/200 1.0 introduction 1.1 general bacharach analyzers are easy to use, but it is essential that these oper- ating instructions be read and understood by all operators and mainte- nance personnel prior to using or servicing the instrument. The bacharach mgc series of moni...

  • Page 6

    Mgc 100/200 instruction 0019-9322 1.3 applications • piped medical gas checking 1.4 instruction manual unless otherwise noted, all paragraphs in this instruction manual describe the operation and maintenance of both the mgc 100 and mgc 200. For example, the heading 2.9 battery charge display (mgc 10...

  • Page 7: 2.0 Operation

    Instruction 0019-9322 mgc 100/200 figure 1. Components of the mgc 100/200 a - gas inlet fi tting b - gas outlet fi tting (mgc 200 only) c - lcd display d - irda link e - pump on light / alarm indicator f - press once to switch instrument on; press once to start and stop pump; hold 3 seconds to switc...

  • Page 8

    Mgc 100/200 instruction 0019-9322 2.3 connecting instrument to medical gas outlet before proceeding, turn on the instrument and allow it warm-up per section 2.2. The pump should be off at this time. After warming up, connect the instrument’s gas inlet through the sup- plied fl ow restrictor to the m...

  • Page 9

    Instruction 0019-9322 mgc 100/200 2.4 starting and ending a test with the instrument turned on and connected to the medical gas outlet per sections 2.2 and 2.3, begin testing with the pump off. Read the display as described in sections 2.5 and 2.6. After completing a test, disconnect the sample tubi...

  • Page 10

    Mgc 100/200 instruction 0019-9322 activate the peak-reading mode by pressing and holding the f 3 button for 3 seconds. Once in the peak-reading mode, toggle the display between “peak co2” and “peak co” by momemtarily pressing the f 3 button. Peakco2 peakco 1,530 200 to return the instrument to its c...

  • Page 11

    Instruction 0019-9322 mgc 100/200 co2 ppm 340 clock icon is displayed once for a snapshot, and fl ashes during continuous logging. Battlow 340 = represents full charge battery level = represents low charge 2.7.2 mgc 200 – snapshot & data-logging after obtaining a steady reading, momentarily press th...

  • Page 12

    Mgc 100/200 instruction 0019-9322 2.10 fault condition warning both instruments are capable of alerting the operator of an internal fault condition (i.E., a sensor failure or blockage in the infrared path). If a fault occurs, the instrument’s beeper will sound continuously, and the following message...

  • Page 13: 3.0 Maintenance

    Instruction 0019-9322 mgc 100/200 reset ok factory settings pmg100.5 25/04/01 id no. Xxxxx 3.0 maintenance 3.1 cleaning keep the instrument clean by wiping it with a soft cloth dampened with a mild detergent solution. 3.2 sunlight the unit should not be left out in direct sunlight, or in other areas...

  • Page 14

    Mgc 100/200 instruction 0019-9322 release the f 2 button and zero the gas sensor(s) as described in either section 3.7 or 3.8. Warning! Failure to zero the sensor(s) after resetting the instrument to its factory settings may cause incorrect gas readings to be displayed. 3.6 battery charging when the...

  • Page 15

    Instruction 0019-9322 mgc 100/200 3.7 zeroing the n 2 o sensor (mgc 100) zero the n 2 o sensor of the mgc 100 as follows: 1. Turn on the instrument and allow it to warm up per section 2.2. 2. With the instrument sampling fresh air, turn on the pump by mo- mentarily pressing the button and allow the ...

  • Page 16

    Mgc 100/200 instruction 0019-9322 3.8 zeroing the co 2 & co sensors (mgc 200) zero both the co 2 and co sensors of the mgc 200 as follows: 1. Turn on the instrument and allow it to warm up per section 2.2. 2. With the instrument sampling fresh air, turn on the pump by mo- mentarily pressing the butt...

  • Page 17

    Instruction 0019-9322 mgc 100/200 hose * regulator * n 2 o calibration cylinder 17 liter 2 3 push hose over the analyzer’s inlet connector adjust regulator knob for an outlet pressure of 2 psi (corresponding to a flow rate of between 100 and 200 cc/min.) ensure that pump is not running. Pump light m...

  • Page 18

    Mgc 100/200 instruction 0019-9322 3. Press and hold down the f 2 button until the following displays appear. Note that the instrument beeps 5 times when it enters the user cal mode, and then emits a steady tone indicating that the f 2 button can now be released. An operator can abort this procedure ...

  • Page 19: 4.0  Parts & Service

    Instruction 0019-9322 mgc 100/200 4.0 parts & service 4.1 replacement parts and accessories complete kits mgc 100 – includes instrument capable of measuring n 2 o, a battery charger, particulate fi lter, and a fl ow restrictor ............0019-8058 mgc 200 – includes instrument capable of measuring ...

  • Page 20

    Mgc 100/200 instruction 0019-9322 4.2 bacharach service centers united states 621 hunt valley circle new kensington, pa 15068 phone: 1-800-736-4666 fax: 724-334-5001 e-mail: help@mybacharach.Com canada bacharach of canada, inc. 20 amber st. Unit #7 markham, ontario l3r sp4 canada phone: 905-470-8985...

  • Page 21

    Instruction 0019-9322 mgc 100/200

  • Page 22

    Mgc 100/200 instruction 0019-9322 headquarters: 621 hunt valley circle, new kensington, pa 15068 ph: 724-334-5000 • fax: 724-334-5001 • toll free: 1-800-736-4666 website: www.Mybacharach.Com • e-mail: help@mybacharach.Com printed in u.S.A..