Bacharach R-22id Instruction

Manual is about: R22 Refrigerant Indentifier

Summary of R-22id

  • Page 1

    Instruction 2100-9002 operation and maintenance rev. 0 - june 2010 r22 id r22 refrigerant indentifier.

  • Page 2: Warranty

    Warranty bacharach, inc. Warrants to buyer that at the time of delivery this product will be free from defects in material and manufacture and will conform substantially to bacharach inc.’s applicable specifi cations. Bacharach’s liability and buyer’s remedy under this warranty are limited to the re...

  • Page 3: Contents

    Contents 1 introduction ...................................................................................................1 1.1 how to use this manual ...........................................................2 1.2 warnings and cautions ................................................................

  • Page 4

    Notes.

  • Page 5: 1 Introduction

    1 r•22 id instruction 2100-9002 1 introduction thank you for purchasing the bacharach r•22id refrigerant identifi er. The bacharach r•22id is an economical instrument designed to provide a “pass” or “fail” indication for r22 purity. The product will also indicate if an excess amount of non-condensab...

  • Page 6: 1.2  Warnings and Cautions

    R•22 id instruction 2100-9002 2 1.1 how to use this manual this manual provides important information on how to operate and maintain bacharach’s r•22id refrigerant analyzer. To assure operator safety and proper use of the r•22id, please read, understand, and follow the contents of this manual. 1.2 w...

  • Page 7

    3 r•22 id instruction 2100-9002 1.2.2 general warnings & cautions • always inspect the sample hose before each use. Replace the hose if it appears cracked, frayed, obstructed or fouled with oil. • always turn the ac system off before connecting the instrument to an air condi- tioning system. • alway...

  • Page 8

    R•22 id instruction 2100-9002 4 1.3 features and capabilities the r•22id refrigerant identifi er is a highly advanced instrument capable of identifying r22 purity. Features of the r•22id include: • stable four gas infrared (ir) sensor • 95% pure r22 pass/fail criteria • simple to understand led driv...

  • Page 9: 2 Operation

    5 r•22 id instruction 2100-9002 2 operation 2.1 components spare filter connector with filter base module 2.2 using the instrument warning: be sure to turn off the system to be tested and let it rest for 3 minutes before using the r•22id to analyze its refrigerant purity. 1. Remove the rubber protec...

  • Page 10

    R•22 id instruction 2100-9002 6 2. Turn on the power switch located on the top of the unit. For battery operation, press the switch to “bat.” for auxiliary power operation, connect the optional auxiliary power supply to the bottom of the unit and press the switch to “aux.” 3. The lights will sequenc...

  • Page 11: 3 Troubleshooting

    7 r•22 id instruction 2100-9002 3 troubleshooting unit fails to power on: check the battery and replace with a fresh one. If using the optional auxiliary power supply, ensure that the power plug is fully inserted into the power socket on the unit. Excess air / fail: the r•22id is equipped with a uni...

  • Page 12: 4 Service Centers

    R•22 id instruction 2100-9002 8 4 service centers service and replacement parts can be found by contacting any of the following bacharach service centers: united states bacharach, inc. 621 hunt valley circle new kensington, pa 15068 phone: 724-334-5000; press 2 at prompt fax: 724-334-5723 email: hel...

  • Page 13

    9 r•22 id instruction 2100-9002 notes:.

  • Page 14

    R•22 id instruction 2100-9002 10 notes:.

  • Page 15

    11 r•22 id instruction 2100-9002 notes:.

  • Page 16

    World headquarters: 621 hunt valley circle, new kensington, pa 15068 phone: 724-334-5000 • toll free: 800-736-4666• fax: 724-334-5001 website: www.Mybacharach.Com • email: help@mybacharach.Com.