    Tru pointe ® ultra ultrasonic leak detector instruction 0028-9000 operation and maintenance rev. 1 - may 2010 the measurable difference ®.

  • Page 2

    Warranty the bacharach tru pointe ® ultra is warranted for one year to be free of manufacturing defects adversely affecting performance. Should an instrument fail within the one year warranty period, the unit will be repaired or replaced provided in the opinion of the factory, the instrument has not...

  • Page 3: Contents

    Contents 1 about this manual ................................................................................................1 warning statements .........................................................................1 caution statements ...............................................................

  • Page 4

    Notes.

  • Page 5: 1  About This Manual

    1 tru pointe® ultra instruction 0028-9000 1 about this manual thank you for investing in a bacharach tru pointe ® ultra ultrasonic leak detector. To assure operator safety and the proper use of the tru pointe ® ultra, please read the contents of this manual, which provides important information on t...

  • Page 6: 2 Introduction

    Tru pointe® ultra instruction 0028-9000 2 2 introduction general description the tru pointe ® ultra ultrasonic leak detector is an electronic instrument that detects the inaudible high frequency sound (ultrasound) of high pressure leaks and converts it to sound a human can hear. Using patented techn...

  • Page 7: 3 Specifi Cations

    3 tru pointe® ultra instruction 0028-9000 3 specifi cations physical dimensions 4.15”l x 2.4”w x .875”d (105 mm x 61 mm x 22.22 mm) overall length 5.5” (140 mm) body material abs body finish blue abs connector 3.5 mm stereo weight 0.3 lb. (138 g) including battery electrical sensitivity -80 db/v- μ ...

  • Page 8: 4 Operation

    Tru pointe® ultra instruction 0028-9000 4 4 operation physical to begin using the tru pointe ® ultra, fi rst take a moment to become familiar with the unit’s controls in figure 1 and 2. Figure 1. Figure 2. Taking readings general 1. Put on the headphones and plug them into the headphone jack on the ...

  • Page 9

    5 tru pointe® ultra instruction 0028-9000 airborne leak detection the tru pointe ® ultra is capable of detecting airborne leaks from up to 40 feet away. When an ultrasonic signal generated from a leak is detected, it will be indicated by an increase in the led meter and a rushing sound will be heard...

  • Page 10

    Tru pointe® ultra instruction 0028-9000 6 operating tips 1. If the test area is large, remove the nose cone. Without the nose cone the detec- tion area of the tru pointe ® ultra increases from 15° to 90°. 2. If the leak is in a tight, or inaccessible area, use the supplied wave guide to deter- mine ...

  • Page 11: Using The Touch Probe

    7 tru pointe® ultra instruction 0028-9000 using the touch probe the patented touch probe accessory is a device that converts solid-borne sounds into airborne sound the tru pointe ® ultra can detect. For example, the sound of an internal leak in a water valve will travel to its surface. Touching the ...

  • Page 12: Using The Soundblaster

    Tru pointe® ultra instruction 0028-9000 8 using the soundblaster ® some tru pointe ® ultra kits include bacharach’s ultrasonic sound generator, the soundblaster ® . The soundblaster ® is used to arti fi cially pressurize items and detect potential leaks using a 115db ultrasonic tone. The tru pointe ...

  • Page 13

    9 tru pointe® ultra instruction 0028-9000 soundblaster ® applications the soundblaster ® is an excellent tool for weatherizing buildings by detecting leaks in windows, doors and roofs. To effectively use the soundblaster ® and tru pointe ® ultra to check for building leaks: 1. Place the soundblaster...

  • Page 14: 5  Care and Service

    Tru pointe® ultra instruction 0028-9000 10 5 care and service cleaning both the tru pointe ® ultra and soundblaster ® can be cleaned using dish soap and a damp cloth. Remove the batteries and close the battery door before cleaning. Do not allow water to enter the unit, especially near the sensor. Af...