BACtrack S80 Owner's Manual - page 7
10
11
Flow Detection Settings
use this option to adjust how hard a user
is required to blow. Press start to change
the settings.
Standard level flow detection
This is the default setting for the unit.
High level flow detection
Press start to change to the high level
flow setting. This level requires a
more forceful breath by the user.
User activated test mode
Press start again to change to the user
activated test mode. when testing in this
mode the operator must press start during
a breath sample to activate the pump and
perform a test.
Low level flow detection
Press start again to change to the low
level flow setting. This level requires a less
forceful breath by the user. This setting is
helpful for subjects with decreased lung
capacity and can also be helpful if a
user has received the Flo error result.
speCIfICaTIOns
Dimensions
2.3 x 4.8 x 0.8 inches
(5.8 x 12.2 x 2.2 cm)
weight
4.8 oz (136 g)
with mouthpiece and batteries
sensor
Technology
Xtend
™
electro-chemical fuel-cell
technology
Detection range
0.000 – 0.500 %BaC
Test Count
Displays total number of tests performed
Power supply
Two aa alkaline batteries, included
Battery life
approximately 1500 tests
warm up Time
10-30 seconds, depending on last use
response Time
3 seconds
sensor
accuracy
+/- 0.005 at 0.050% B.a.C.
Operating
Temperature
32-104 °F (0-40 °C)
This device has been tested using nHTsa/DOT procedures. In
this testing, the accuracy of this device was established at Blood
alcohol Concentrations (BaC) of 0.008 and 0.032, but not at
greater concentrations. additional laboratory testing has been
performed at concentrations ranging from 0.00 – 0.40% BaC.
BAC
BAC
BAC
BAC
BAC