Badger Meter 220BR Installation & Operation Manual

Manual is about: Insertion Style Flow Sensors

Summary of 220BR

  • Page 1

    Series 200 insertion style flow sensors installation & operation manual 872020-en (august 2012) rev. 8 important: this manual contains important information. Read and keep for reference..

  • Page 2: Contents

    Series 200 flow sensors contents introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 mechanical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 general . . . . ...

  • Page 3: Introduction

    Installation & operation manual the impeller friction to increase, which may affect performance at low flow rates. Any circumferential location is correct for installation in vertical pipes. 3. An insertion depth of 1-1/2 inches for pipe sizes 2.5 inches and larger is required for accurate flow rate...

  • Page 4: Hot Tap Installation For

    Series 200 flow sensors 3 ¾” 2 03 4 5 adjusting nuts figure 1: installation for 220br and 220ss 3. Clean o-rings and flow sensor sleeve, and lightly lubricate o-rings with silicone grease from the packet provided or some other acceptable lubricant. Take care not to get grease on the impeller or bear...

  • Page 5: Installation Into A

    Installation & operation manual the alignment of the impeller with the flow in the pipe is accomplished by aligning the two “sight holes” at the top of the sensor tube assembly with the center line of the pipe. Make sure the alignment is made to the pipe and not to a wall or surface near the sensor....

  • Page 6: Electrical Installation

    Series 200 flow sensors 1. Set one set of hex/jam nuts so that the distance between the top surface of the hex nut and the top surface of the hex mounting adaptor is equal to the “d” dimension calculated above. Then adjust the other two sets of hex/jam nuts 1-1/2 inches below the first jam nut to al...

  • Page 7: Electrical Installation

    Installation & operation manual 5. Do not make an underground splice unless absolutely necessary. 6. Route the cable from the sensor to a badger meter flow monitor/transmitter. The cable may be extended up to 2000 feet, using 2-conductor shielded 20 awg or larger stranded copper wire with appropriat...

  • Page 8

    Series 200 flow sensors page 8 august 2012.

  • Page 9: Calibration

    Installation & operation manual calibration badger meter sensors use unique k and offset numbers for calibration. These numbers are derived from calibration runs using nist traceable instruments. Using both a k and an offset number provides higher accuracy than using a k (pulse/gal) factor alone. K ...

  • Page 10

    Series 200 flow sensors column 1 column 2 column 3 column 4 column 5 column 6 suggested operating pipe size pipe o.D. Pipe i.D. K offset range (gpm) 3 inch sch 10s 3.500" 3.260" 5.009 .090 12-400 std. Wt., sch 40 3.5" 3.068" 4.362 .063 12-400 extra strong, sch 80 3.5" 2.900" 3.858 .043 12-400 pvc cl...

  • Page 11

    Installation & operation manual column 1 column 2 column 3 column 4 column 5 column 6 suggested operating pipe size pipe o.D. Pipe i.D. K value offset range (gpm) 14 inch sch 10s 14.00" 13.500" 122.307 0.391 200-6,000 sch 20 14.00" 13.375" 120.216 0.388 200-6,000 std. Wt., sch 30 14.00" 13.250" 118....

  • Page 12: Replacement

    Series 200 flow sensors impeller assembly and shaft replacement if you are replacing an existing badger meter sensor and have already calibrated your flow monitor/transmitter, no calibration changes are necessary. For installation of a new flow monitor or for relocation of a sensor in a new pipe siz...

  • Page 13: Specifications

    Installation & operation manual 2. If you suspect that the sensor is bad, you can test the monitor circuitry by connecting a piece of wire to one of the sensor input terminals and tap the other side of the wire to the other sensor input terminal. Shorting across the sensor input terminals on and off...

  • Page 14

    Series 200 flow sensors this page intentionally left blank. Page 14 august 2012.

  • Page 15

    Installation & operation manual this page intentionally left blank. Page 15 august 2012.

  • Page 16

    Www.Badgermeter.Com data industrial is a registered trademark of badger meter, inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, badger meter reserves the right to change product or syste...