Baldor OHV Series 3KW-9KW Operator's manual - Location

Manual is about: OHV Series 3KW-9KW

Summary of OHV Series 3KW-9KW

  • Page 1

    Operator's manual for your premier pow’r products generators ohv series 3kw-9kw baldor generators 3815 oregon. Street • oshkosh wi 54902 telephone 236-4200 • fax 920-236-4219 form#: s-psg-002-7 effective date: 4/4/97 ohv series cover\msw'00 revision date: 9/24/02.

  • Page 2

    Forward this manual contains the information you need to safely and efficiently operate your generator set. During the preparation of this manual every effort was made to ensure the accuracy of its contents. Do not operate this generator set until you carefully read this manual and understand the sa...

  • Page 3

    ♦ place protective covers and guards over the rotating parts, if rotating parts such as the drive shaft, pulley, belt, etc. Are left exposed, they are potentially hazardous. ♦ when cleaning, repairing or inspecting, make sure all moving parts have stopped. ♦ prior to working on the generator set, di...

  • Page 4

    ♦ know how to stop the engine quickly and understand the operation of all controls. ♦ never permit anyone to operate the generator set without proper instructions. ♦ never allow children to operate the generator set. ♦ children and pets must be kept away from the area of operation due to the possibi...

  • Page 5

    ♦ always treat the electrical circuits as if they were energized. ♦ disconnect all leads plugged into the unit prior to working on it. ♦ have the electrical circuits serviced only by qualified technicians. ♦ inspect wiring frequently and replace frayed, broken or poor leads. ♦ do not connect this un...

  • Page 6

    ○ ○ ○ ○ for gasoline or diesel powered generator sets ○ ○ ○ ○ ♦ check all fuel supply piping and their connections on a monthly basis for fuel leaks. ♦ use only approved piping and componentry in your fuel supply system. ♦ a professional, experienced technician should only install the fuel supply sy...

  • Page 7

    Table of contents section page basic location information…………………………………………………………………………………………………..1 basic connection information……………………………………………………………………………………………..2 basic engine information………………………………………………………………………………………………………….3 generator end maintenance……………………………………………………………………………………………………..4 b...

  • Page 8: Location

    Location for best service from your stationary generator set there are several factors which should be taken into consideration when choosing the best location in which to permanently mount it: moisture: all electrical equipment should be protected from excessive moisture. Failure to do so will resu...

  • Page 9

    Connections wiring: use sufficiently large insulated wire to connect the generator set to the load. The gauge of the wire will depend largely on the distance, the permissible voltage drop, and the size and type of load. If you are not sure of the gauge wire needed for your application, consult a com...

  • Page 10

    Engine information this operator's manual only covers basic day-to-day engine operating instructions. However, the engine manufacturer's manual is included with your generator set and should be referred to for any additional information you may need. Become familiar with and follow all the engine ma...

  • Page 11

    Maintenance maintenance should only be performed on the generator set after the engine has stopped and the generator set has cooled down. The battery and spark plug should also be disconnected prior to performing maintenance. Generator end maintenance generator end maintenance consists of cleaning t...

  • Page 12

    Equipped with this feature). Make sure that the auto idler magnet does not touch the throttle lever of the engine when it is running and the auto idler switch is turned off. √ adjust the engine speed to 3720 rpm's (62 hz) with no load applied to the generator set. √ adjust the auto idler speed after...

  • Page 13

    Storage if you will not be using the generator set for a significant amount of time (3 months or longer) you should store the generator to prevent any problems that could arise from sitting idle. Please fully read the following guidelines prior to storing the unit. 1. Remove all fuel from the engine...

  • Page 14

    Use of electric motors electric motors require much more current (amperes) to start them than to run them. Some motors, particularly split-phase motors are very difficult to start and requires 5 to 7 times as much current to start them as it does to run them. Repulsion-induction type motors are the ...

  • Page 15: Service

    Ordering parts when generator repair parts are needed, they may be obtained by calling the parts department at baldor generators or the nearest local office of baldor electric company. Accurate information such as the following will assure that you receive accurate parts for your particular generato...

  • Page 16

    Operation prior to starting the unit: 1. Locate and set up the generator set in an open, dry, well ventilated and reasonably level location. Operating this unit in an area not suitable for it's proper use may cause damage to the unit, severe injury, or death. See "location information" section locat...

  • Page 17

    If the engine does not start after turning the engine over a few times, smell for fuel near the air cleaner. If there is a significant gasoline smell coming from the air cleaner, turn the choke lever off and attempt to start the engine with the choke off. D. After the engine has started, turn the en...

  • Page 18

    Simple troubleshooting listed below are the more simple solutions to some of the more common problems that are reported to the service department at baldor generators. These troubleshooting solutions are meant to be an aid for a person who has minimal electrical knowledge and experience. More in-dep...

  • Page 19

    E. Restart the unit and check for voltage output. Be extremely careful when using the alternate method for flashing the generator as you will be working around fast, rotating components along with live wires and bare connections. Low voltage output possible problems: 1. Generator speed too slow. If ...

  • Page 20: Control Panel

    Control panel for ohv30 a = nema 515r gfci duplex. This receptacle is a ground fault circuit interrupter duplex rated at 20 amps. This receptacle must be tested on a regular basis (monthly). B = standard duplex receptacle. This is your standard household duplex receptacle, it is rated for 120 vac, 1...

  • Page 21: Control Panel

    Control panel for ohv40, ohv50, ohv60 a = nema 515r gfci duplex. This ground fault circuit interrupter duplex is rated at 125vac, 20 amps. This receptacle must be tested on a regular basis (monthly). B = ac circuit breakers. These circuit breakers provide overload protection for the generator set. W...

  • Page 22: Control Panel

    Control panel for ohv85 a = the auto idler feature on/off switch. The auto idler feature allows the engine on the generator set to slow down to a "slow speed position" when there is no load being applied to the unit. When a load is applied to the unit the auto idler circuitry allows the engine to sp...

  • Page 23: Generator-End Componentry

    Generator-end componentry ohv30 genset - 16 -.

  • Page 24: Parts Breakdown

    Parts breakdown for ohv30 generator sets: ref letter old part # new part # description a 46.10025c 61sa0019a01 stator assembly b 66.00025 61ra0011a00 rotor assembly d 230.02020 10xn3124k12 bolt to attach rotor e 230.04020 10xn3124y14 bolt to attach engine adaptor f 230.12010 84xn1032l10sp bolt to at...

  • Page 25

    Generator-end componentry ohv40, ohv50, ohv60 control box componentry ohv40, ohv50, ohv60 - 18 -.

  • Page 26: Parts Breakdown

    Parts breakdown for ohv40, ohv50, ohv60 generator sets: ref letter old part # new part # description a 46.00045d 61sa0010a02 stator assembly for 4000 to 5000 watt units a 46.00055b 61sa0013a00 stator assembly for 6000 watt units b 66.00045 61ra0013a00 rotor assembly for 4000 to 5000 watt units b 66....

  • Page 27

    Generator-end componentry ohv85 control box componentry ohv85 - 20 -.

  • Page 28: Parts Breakdown

    Parts breakdown for ohv85 generator sets: ref letter old part # new part # description a 46.10075b 61sa0022a01 stator assembly b 66.00075 61ra0016a00 rotor assembly c 140.00200 ct0046a00sp idler transformer d 230.04040 consult factory bolt to attach rotor ***** e 230.08030 consult factory bolt to at...

  • Page 29

    Wiring diagram ohv30 - 22 -.

  • Page 30

    Wiring diagram ohv40, ohv50, ohv60 - 23 -.

  • Page 31

    Wiring diagram ohv85e - 24 -.

  • Page 33

    Limited warranty effective august 1, 2003 unless otherwise provided, baldor generators are warranted against defects in baldor workmanship and materials for a period of time as set forth in the warranty period chart below. If a baldor product is defective due to baldor workmanship or materials and t...

  • Page 34

    *labor coverage for warrantable repairs is provided for the applicable period not to exceed published rates as contained in the baldor generators warranty policy. Mileage is allowed only for permanent installations not to exceed published rates as contained in the baldor generators warranty policy. ...

  • Page 35

    California proposition 65 warning engine exhaust from this product contains chemicals known to the state of california to cause cancer, birth defects, and other reproductive harm. California proposition 65 warning diesel engine exhaust and some constituents are known to the state of california to ca...

  • Page 36

    Service is just a phone call away: 800-872-7697 www.Baldor.Com/products/generators.Asp 3815 oregon street oshkosh wi 54902 phone: (920) 236-4200 fax: (920) 236-4219.