  • Page 1

    English bes m30ep-pfc12f-s04g-d12 bes q40zu-pfc15b-s04g-d12 bes q40zu-pfc20f-s04g-d12 inductive safety sensors user's manual.

  • Page 2: Www.Balluff.Com

    Www.Balluff.Com original user's guide all rights reserved. Protected within the legally permissible limits of the united states and internationally. This document may not be copied or modified without prior written permission from balluff. All the trademarks and names appearing here are for identifi...

  • Page 3: General Safety Notes

    1 about this user's guide 4 1.1 typographical conventions 5 1.2 abbreviations 6 1.3 warnings 6 2 about this product 8 2.1 product description 8 2.2 scope of delivery 8 2.3 funktion 9 2.4 release zone 10 2.5 relevant standards 12 3 general safety notes 13 3.1 approved use 13 3.2 non-approved use 14 3...

  • Page 4: About This User'S Guide

    1 about this user's guide this user's guide contains all the information you need for operating the following inductive safety sensors: – bes0577 – bes057a – bes057c for questions that go beyond the scope of this user's guide, our technical customer service is available for any function-related info...

  • Page 5: Actions

    1.1 typographical conventions actions individual action instructions are indicated by a preceding triangle: ► action instruction ⇒ result of action ► action instruction 2 action sequences are numbered in order: 1. Step 1 2. Step 2 3. Step 3 symbols note the symbol and the word note indicate informat...

  • Page 6: 1.2  Abbreviations

    1.2 abbreviations ccf common cause failure failure as a consequence of as common cause dc diagnostic coverage diagnostic coverage mttfd mean time to dangerous failure mean time to dangerous failure pfh (pfhd) probability of (dangerous) failure per hour probability of (dangerous) failure per hour pl ...

  • Page 7: Slight Or Moderate

    Signal word type and source of the hazard consequences of non-observance ► measures for hazard avoidance the signal words used have the following meaning: notice the warning word notice indicates a risk which can result in damage to or destruction of the product. Caution the general warning symbol c...

  • Page 8: About This Product

    2 about this product 2.1 product description the inductive safety sensor type bes057a, bes057c, and bes0577 detects metal without contact. 2.2 scope of delivery type scope of delivery order code bes q40zu-pfc15b-s04g-d12: – 1 safety sensor with pre-attached mounting bracket – 1 allen wrench for fixi...

  • Page 9: 2.3  Funktion

    2.3 funktion bes057a: "0" "1" 1 safety sensor 2 close zone 3 release zone 4 assured turn-off distance sar 5 damping element yellow signal led: switching state green power led: operating voltage bes057c: "0" "1" 1 safety sensor 2 close zone 3 release zone 4 assured turn-off distance sar 5 damping ele...

  • Page 10: 2.4  Release Zone

    Bes0577: "0" "1" leds 1 safety sensor 2 close zone 3 release zone 4 assured turn-off distance sar 5 damping element yellow signal led: switching state green power led: operating voltage figure 2 function overview 2.4 release zone the outputs (ossds) are only released when damping occurs in the relea...

  • Page 11: Note

    Please refer to the following table for the assured turn-off distance sar for the various sensors: order code turn-off distance bes057a > 30 mm bes057c > 45 mm bes0577 > 30 mm release zone for selected materials1): material release zone bes057a bes057c bes0577 fe360 (=st37k) 10…15 mm 4…20 mm 6…12 mm...

  • Page 12: 2.5  Relevant Standards

    2.5 relevant standards the following directives and standards were applied: – 2006/42/eg european machine directive – 2014/30/eu emc directive – en iso 13849-1:2015 safety of machinery – safety-related parts of control systems – part 1: general principles for design – iec 60947-5-2:2007 + a1:2012 lo...

  • Page 13: General Safety Notes

    3 general safety notes 3.1 approved use safety function sf: the safe condition (final stage turned off, logical "0") is achieved when there is undamping greater than or equal to the safe turn-off condition sar (see section technical data on page 36). Also observe the instructions for installing the ...

  • Page 14: 3.2  Non-Approved Use

    3.2 non-approved use warranty and liability claims against the manufacturer are rendered void by: – unauthorized tampering – improper use – use, installation or handling contrary to the instructions provided in this user's guide. – the sensor is not permitted to be used as a mechanical stop. – measu...

  • Page 15

    – the device may be installed, connected and put into service only by a person trained in safety technology and electronics. – the relevant technical standards must be considered as part of the respective application. – observe the requirements of en 60204 when installing. – if the device malfunctio...

  • Page 16: Functional Impairments

    Observe the following conditions:: ► take measures which prevent metallic objects from unknowingly contacting the active surface. ► for interlocking devices together with guards observe din en iso 14119. ► maintain specified application conditions (see section technical data on page 36). ► use of th...

  • Page 17: Installation

    4 installation 4.1 mounting and installation conditions for bes057a and bes057c orient sensor face 2 1 3 4 2 1 3 4 2 1 3 4 2 1 3 4 the cable socket can be rotated: 6 7 5 6 7 5 6 7 5 figure 3 material of sensing surface www.Balluff.Com 17 bes m/q…-d12 inductive safety sensors.

  • Page 18

    Installation conditions for bes057a: the device cannot be installed flush in steel per iec 60947-5-2, type i2c40sp2. In addition the device may be installed flush on steel on one side. In copper, aluminum and brass the device can be flush mounted per iec 60947-5-2, type i1c40sp2. ► secure the device...

  • Page 19

    Installation conditions for bes057c: the device cannot be installed flush in steel per iec 60947-5-2, type i2c40sp2. Flush mounting of the safety sensor is not permitted since an increase of the switching distance up to release of the outputs (ossds) may occur. ► secure the device against coming loo...

  • Page 20: Bes0577

    4.2 mounting and installation conditions: bes0577 the device cannot be installed flush in steel per iec 60947-5-2, type i2c40sp2. ► secure device against loosening (tightening torque ≤ 50 nm). ► note installation conditions per figures 1 to 3: figure 6 minimum distances from metal surfaces for bes05...

  • Page 21

    4.3 measures against simple circumvention the safety sensor responds to metallic objects, e.G. The frame of a safety door. Other metallic objects which are not supposed to result in release of the sensor must not cause an unintended release of the safety sensor. In addition, the sensor has the follo...

  • Page 22

    The clear zone can be unblocked as follows: – undamp (> 30 mm) for a time of more than 2 sec type undamp bes057a > 30 mm bes057c > 45 mm bes0577 > 30 mm – voltage interruption (see section 6.3 disabling the calibration aid on page 26). 22 bes m/q…-d12 inductive safety sensors.

  • Page 23: Electrical Connection

    5 electrical connection notice exceeding maximum voltage in case of a single fault, if the supply voltage of 60 v exceeds the maximum supply voltage of 120 v dc for more than 0.2 sec. Can result in destruction of the device and loss of the safety functionality. ► ensure separation of the supply volt...

  • Page 24: Startup

    6 startup 6.1 calibration aid for simple and safe installation the sensor has an optical setup aid for visualizing the release zone. Bes057a: 30 0 > 5 s mm signal power the setup aid is activated by bringing the metallic object in front of the safety sensor (close zone). After approx. 5 sec. The yel...

  • Page 25

    6.2 determining the release zone when the setup aid is activated, moving the damping element (or the sensor if the target is fixed) allows the release zone to be determined. 30 0 > 5 s mm signal power as soon as the target arrives in the release zone the yellow led turns off. If the target is locate...

  • Page 26

    6.3 disabling the calibration aid bes057a: 30 0 mm signal power > 2 s signal power if the sensor is undamped (> 30 mm) for more than 2 sec., the setup aid is turned off and the yellow signal led goes out. This can also be accomplished by interrupting the supply voltage. Bes057c: 45 0 mm signal power...

  • Page 27: Safe Condition

    6.4 switching state of the outputs safe condition the safe condition is a turned-off condition (unpowered condition: logic "0") of at least one of the outputs a1 or a2 (ossds). If one of the outputs a1 or a2 is turned off, the downstream safety logic unit must bring the entire system into the condit...

  • Page 28

    Cross-connection / short circuit – crossing both the outputs (a1 and a2) is detected by the sensor and results in turning off the outputs (ossds) at the next safety request. The outputs a1 and a2 remain turned off until the fault is eliminated and a voltage reset has been performed. – a short-circui...

  • Page 29: Operation

    7 operation 7.1 operating mode the duration of the previous undamping determines whether the yellow signal led comes on immediately or with a time delay when a damping object enters the release zone. In any case the outputs turn on with no time delay. When undamping, the outputs turn off and the yel...

  • Page 30

    Delayed switching of the signal led bes057a: undamping 30 0 > 3 s mm signal power if the damping element was removed from the sensor for more than approx. 2 sec. (> 30 mm), the yellow signal led comes on when damping in the release zone with a delay of approx. 3 sec. This is also the case if the dam...

  • Page 31

    Non-delayed switching of the signal led bes057a: undamping 30 0 ≈ 0 s *) mm signal power if the damping element was removed from the sensor for less than 2 sec. (> 30 mm), the yellow signal led comes on with no delay when damping in the release zone. Bes057c: undamping 45 0 ≈ 0 s *) mm signal power ...

  • Page 32: 7.2  Response Times

    7.2 response times type response time response time to a safety request (removing from the release zone) ≤ 50 ms response time when approaching the close zone (non-safety relevant done) ≤ 100 ms response time when approaching the release zone (release time) typ. 100 ms ≤ 200 ms risk time / error res...

  • Page 33

    Type response time test pulse interval tp (2) [pulse packet] 1 0 t 1 0 t response times min. 2 ms max. 5 ms 1 test pulse duration 2 test pulse interval tp (pulse packet) 3 test pulse interval t test pulse interval t (pulse packet repetition) min. 30 ms max. 50 ms www.Balluff.Com 33 bes m/q…-d12 indu...

  • Page 34: 7.3  Led Display

    7.3 led display sensor type bes057a, bes057c: led operating status outputs a1 (ossd) a2 (ossd) signal no supply voltage both outputs turned off 0 0 power signal undervoltage 0 0 power signal overvoltage both outputs turned off 0 0 power signal damping element outside the release zone (operating mode...

  • Page 35: Sensor Type Bes0577:

    Sensor type bes0577: led operating status outputs a1 (ossd) a2 (ossd) signal no supply voltage both outputs turned off 0 0 power signal undervoltage 0 0 power signal power overvoltage both outputs turned off 0 0 sensor error (see section 9.1 troubleshooting on page 40) one output or both outputs tur...

  • Page 36: Technical Data

    8 technical data bes057a bes057c bes0577 bes057a bes057c bes0577 product features plug connection m12 release zone 10…15 mm 4…20 mm 6…12 mm non-flush mount meets the requirements en iso 13849-1:2015, category 4 pl e iec 61508: sil 3 iec 62061: silcl 3 area of use operating mode continuous operation ...

  • Page 37

    Bes057a bes057c bes0577 rated isolation voltage 30 v current consumption protection class iii polarity reversal protection yes ready delay time 5 s outputs output function 2 x ossd (a1 and a2) output voltage at 24 v compatible with en 61131-2, inputs type 1, 2 voltage drop 2.5 v; (100 ma) current lo...

  • Page 38

    Bes057a bes057c bes0577 environmental conditions operating conditions class c per en 60654-1 weather-protected ambient temperature –25...70 °c –25...60 °c –25...70 °c for mission time ≤ 87,600 h 10…40 °c, for mission time ≤ 175,200 h temperature change rate 0.5 k/min max. Permissible relative humidi...

  • Page 39

    Bes057a bes057c bes0577 mechanical data installation type non-flush mount housing material ppe; zinc die-cast ppe; zinc die-cast v4a (1.4404); pbt weight 0.346 kg 0.315 kg 0.255 kg displays/operating elements display led yellow (signal) led green (power) electrical connection connection m12 plug con...

  • Page 40: 9.1  Troubleshooting

    9 maintenance, care, and disposal no special measures for maintenance and upkeep are necessary when operated properly. The device may be repaired only by the manufacturer. Dispose of the device in accordance with the prevailing national regulations for environmentally safe disposal. 9.1 troubleshoot...