Balluff BIS U-870 Technical Description, User's Manual

Manual is about: Handheld Programmer

Summary of BIS U-870

  • Page 1

    English handheld programmer bis u-870 technical description, user's guide.

  • Page 2

    Www.Balluff.Com.

  • Page 3

    Www.Balluff.Com handheld programmer bis u-870 3 6 5 4 3 2 1 user instructions 4 1.1 ce declaration of conformity and user safety 4 1.2 scope of delivery 4 1.3 about this manual 4 1.4 structure of the manual 4 1.5 typographical conventions 5 1.6 symbols 5 1.7 abbreviations 5 safety 6 2.1 intended use...

  • Page 4

    Handheld programmer bis u-870 4 user instructions 1 1.1 ce declaration of conformity and user safety 1.2 scope of delivery 1.3 about this manual 1.4 structure of the manual declaration of conformity this product was developed and produced in compliance with applicable european standards and directiv...

  • Page 5

    Www.Balluff.Com handheld programmer bis u-870 5 1.5 typographical conventions enumerations actions cross-references buttons menu commands keys 1.6 symbols 1.7 abbreviations the following conventions are used in this manual. Enumerations are shown as a list with an en-dash. Entry 1, – entry 2. – acti...

  • Page 6

    Handheld programmer bis u-870 6 2.1 intended use 2.2 general safety notes 2.3 notes on using and returning rechargeable batteries 2.4 meaning of the warning notes the bis u-870 handheld programmer is a component of the bis u identification system. Within the identification system it checks, corrects...

  • Page 7

    Www.Balluff.Com handheld programmer bis u-870 7 note the international commission of radiological protection (icrp) has specified limit values for the exposure of humans to rf fields. These limit values are also recommen- ded by the icnirp (international commission of non ionizing radiological prote...

  • Page 8

    Handheld programmer bis u-870 8 3.1 battery operation changing rechargeable batteries and operating life charging rechargeable batteries note the system components of the handheld programmer are powered by a 3.7 v rechargeable battery pack (li-ion). Please charge rechargeable batteries provided by b...

  • Page 9

    Www.Balluff.Com handheld programmer bis u-870 9 3.2 overview of workabout pro bis u-870 3.3 cold reset or battery replacement saving your own profile with „total recall“ 3.4 turning the handheld programmer (workabout pro 3 ) on/off figure 2: bis u-870-1-008-x-000 handheld programmer 1 read/write hea...

  • Page 10

    Handheld programmer bis u-870 10 getting started 3 turning on turning off 3.5 turning the handheld programmer (workabout pro g2) on/off turning on turning off 3.6 keyboard, display, and operating concept 3.7 creating your own operating interface attention! This is a class a product. When using this ...

  • Page 11

    Www.Balluff.Com handheld programmer bis u-870 11 3.8 starting the rfid application 3.9 operating menu overview „configuration“ tab on the windows ce desktop, tap on „start > programs > balluff rfid > bis u rfid“ (depending on the windows ce® version, tap on the four-color windows® logo instead of „s...

  • Page 12

    Handheld programmer bis u-870 12 getting started 3 „reader“ submenu this tab is divided into three submenus: „reader“, „read id“ and „r/w“. The following settings can be made under the „reader“ menu: protocol epc c1g2 is set by default. Rf regulation select the rf regulation applicable in the given ...

  • Page 13

    Www.Balluff.Com handheld programmer bis u-870 13 getting started 3 „read id“ submenu figure 7: „configuration“ tab, „read id“ submenu display select the display mode. The display in the read id window can be either ascii or hexadecimal. Read id options the following settings are possible: continuous...

  • Page 14

    Handheld programmer bis u-870 14 getting started 3 figure 8: „configuration“ tab, „r/w“submenu r/w (read/write) options select the display mode the display in the r/w window can be either ascii or hexadecimal. Bank memory defines for the r/w window which memory bank of the data carrier is to be read...

  • Page 15

    Www.Balluff.Com handheld programmer bis u-870 15 getting started 3 „read id“ tab you can read the id of a data carrier on the „read id“ tab. Figure 9: „read id“ tab [read] the [read] button can be used to start the read operation. [clear] use this button to delete the data that were read from the in...

  • Page 16

    Handheld programmer bis u-870 16 getting started 3 „r/w“ tab on the „r/w“ tab, you can read information from the memory of a data carrier or write informa- tion to the memory. Figure 10: „r/w“ tab operate status indicator. As soon as reading or writing begins, the status indicator flashes yellow. [r...

  • Page 17

    Www.Balluff.Com handheld programmer bis u-870 17 getting started 3 „file browser“ and „about“ tabs on the „file browser“ tab, you can save the read data, load existing data or export read-id data. On the „about“ tab, information on the software version and the manufacturer details are displa- yed. F...

  • Page 18

    Handheld programmer bis u-870 18 4.1 function principle of identification systems 4.2 product description creating your own user interface 4.3 control function 4.4 files the portable bis u identification system is classified as a non-contacting system with read and write function. This allows it to ...

  • Page 19

    Www.Balluff.Com handheld programmer bis u-870 19 file format type of memory bank (0x00=reserved, 0x01=epc, 0x02=tid, 0x03=user) no. Of bytes data carrier data 1 byte 2 bytes n bytes example: data carrier file from the user memory bank with 12 bytes of data. Data: abcdefghijkl contents of the data ca...

  • Page 20

    Handheld programmer bis u-870 20 5.1 keyboard, display and operating concept 5.2 reading data carriers read „read id“ familiarize yourself with the operating concept and characteristics of the workabout pro. The operating manual can be found on the included cd or on the internet at: http://www.Psion...

  • Page 21

    Www.Balluff.Com handheld programmer bis u-870 21 read memory of the data carrier 5.3 writing data to read the memory of a data carrier, hold ► the sensing surface of the handheld programmer to the data carrier you wish to read. Click the ► [read] button. The ⇒ „operate“ field begins to flash yellow ...

  • Page 22

    Handheld programmer bis u-870 22 read or write error 5.4 working with files saving files loading files exporting read id note if reading a data carrier or writing to the memory of a data carrier was not successful, the „operate“ field illuminates red. Make certain that there are no objects between t...

  • Page 23

    Www.Balluff.Com handheld programmer bis u-870 23 operation 5 5.5 connecting the handheld programmer to a pc/laptop data transmission charge life the handheld programmer can optionally be connected to a pc/laptop using bluetooth, wlan, or usb (docking station). Files can be sent between the handheld ...

  • Page 24

    Handheld programmer bis u-870 24 dimensions housing connections electrical data operating conditions figure 18: bis u-870-1-008-x-000 dimensions (in mm) weight (including battery pack) 585 grams keyboard 46 keys, alphanumeric display touchscreen tft 3.6" degree of protection ip 65 read head connecti...

  • Page 25

    Www.Balluff.Com handheld programmer bis u-870 25 part designation code accessory (scope of delivery) accessories (optional, not included in scope of delivery) bis u – 870 – 1 –008 – x – 000 balluff identification system series u read/write system hardware type 870 = portable reader with integrated r...

  • Page 26

    Handheld programmer bis u-870 26 features consisting of charger/power supply with 2.5 mm jack plug, – primary connector euro, uk, us interchangeable (included), – ce, ul approvals. – primary voltage u primary 100-240 v ac secondary voltage u sec 6 v dc ± 5 % input frequency f primary 47-63 hz second...

  • Page 27

    Www.Balluff.Com handheld programmer bis u-870 27 ascii table decimal hex control code ascii decimal hex ascii decimal hex ascii 0 00 ctrl @ nul 43 2b + 86 56 v 1 01 ctrl a soh 44 2c , 87 57 w 2 02 ctrl b stx 45 2d - 88 58 x 3 03 ctrl c etx 46 2e . 89 59 y 4 04 ctrl d eot 47 2f / 90 5 a z 5 05 ctrl e...

  • Page 28

    Handheld programmer bis u-870 28 index a abbreviations 5 dimensions 24 charging battery 8 connecting 23 connections 24 ascii table 27 b meaning of the warning notes 6 intended use 6 24 operating conditions c cold reset 9 d files 18 reading data carriers 20 data carrier types 19 data transmission 23 ...

  • Page 29

    Balluff gmbh schurwaldstraße 9 73765 neuhausen a.D.F. Germany tel. +49 7158 173-0 fax +49 7158 5010 balluff@balluff.De no. 877417 e . Edition 1009 ; subject to modifications. Www.Balluff.Com www.Balluff.Com.