Balluff BIS V-6107 User Manual

Manual is about: TCP/IP, USB

Summary of BIS V-6107

  • Page 1

    Bis v-6107 tcp/ip, usb technical description, user's guide 61,9 5,3 157,6 +6,0 31 21,5 36,4 42,7 4 48,2 168,3 +6,0 english.

  • Page 2: Www.Balluff.Com

    Www.Balluff.Com.

  • Page 3

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 3 1 user instructions 5 1.1 about this manual 5 1.2 typographical conventions 5 1.3 symbols 5 1.4 meaning of warning notes 5 1.5 abbreviations 6 2 safety 7 2.1 intended use 7 2.2 general safety notes 7 2.3 conformity 7 2.4 general safety notes 8 ...

  • Page 4

    Bis v-6107 tcp/ip, usb processor unit 4 7 commissioning 31 7.1 supply voltage 31 7.2 startup using usb 31 7.3 driver installation 31 7.4 startup using tcp/ip 33 8 parameter configuration 35 8.1 network parameter 35 8.2 device parameter 35 8.3 rfid parameter 37 8.4 io-link parameter 42 9 protocol 45 ...

  • Page 5

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 5 this manual describes the processor unit for bis v-6107 identification systems and startup instructions for immediate operation. The following conventions are used in this manual. Action instructions are indicated by a preceding triangle. The r...

  • Page 6

    Bis v-6107 tcp/ip, usb processor unit 6 bcc block check character bis balluff identification system cp code present crc cyclic redundancy check i/o port digital input and output port eeprom electrical erasable and programmable rom eirp equivalent isotropically radiated power emc electromagnetic comp...

  • Page 7

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 7 this reference manual applies to processor units in the following series: – bis v-6107-039-c005 – bis v-6107-039-c105 – bis v-6107-039-c006 – bis v-6107-039-c106 the bis v-6107 is part of the bis v identification system and is used for linking ...

  • Page 8

    Bis v-6107 tcp/ip, usb processor unit 8 2 safety ► before connecting the processor unit to a power supply or to an external controller please read this user's guide carefully. ► observe all safety instructions without exception. Notice exceeding maximum current draw when the maximum current draw is ...

  • Page 9

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 9 the identification system bis v is classified as a non-contacting system with read and write func- tion. Data can be written without contact from a higher level controller to a data carrier (tag) and read back from the tag to the controller. Ma...

  • Page 10

    Bis v-6107 tcp/ip, usb processor unit 10 – 1x processor unit bis v-6107 – 1x grounding set – 5x end caps – user's manual – safety notes for information about available software and accessories visit www.Balluff.Com . The processor unit is the link between data carrier and controlling system. It mana...

  • Page 11

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 11 3 basic knowledge read/write heads from different series and of different technologies can be connected to termi- nals h1...H4. An overview can be found in the table below. Series frequency range operating principle bis c_ _ lf inductive bis v...

  • Page 12

    Bis v-6107 tcp/ip, usb processor unit 12 the usb 1.1 full-speed-port can be used to connect the bis v-6107 processor unit to any usb 1.1 compatible usb port. The bis v-6107 is detected by the pc as a system component as soon as it is plugged in and displayed as an interchangeable data carrier with a...

  • Page 13

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 13 3 basic knowledge io-link is defined as a standardized point-to-point connection between sensors/actuators and an i/o module. An io-link sensor/actuator can send additional communication data (e.G. Diag- nostics signals) in addition to the bin...

  • Page 14

    Bis v-6107 tcp/ip, usb processor unit 14 figure 2: mechanical connection 61,9 5,3 157,6 +6,0 31 21,5 36,4 42,7 4 48,2 168,3 +6,0 (dimensions in mm) figure 3: a b installation examples (a: attachment to din rails, b: attachment to t-slotted framing) 1 2 top-hat rail fastening 3 4 t-slotted framing ho...

  • Page 15

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 15 note when installing the bis v assembly in strong emc environments we recommend connecting the housing from the fe terminal directly to ground. The ground connection should be short and stable. A grounding set is included with the product. Whe...

  • Page 16

    Bis v-6107 tcp/ip, usb processor unit 16 note ► fit unused plug terminals with caps to ensure the ip65 enclosure rating. Connections h2 h1 h3 fe h4 tcp/ip power usb io-link anschlüsse power supply voltage bis v and io-link and i/o modules h1…h4 read/write heads usb usb-port tcp/ip ethernet tcp/ip-po...

  • Page 17

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 17 4 installation h1…h4 m12 female, 5-pin, a-coded pin function description 1 v s supply voltage for read/write heads output v s /800 ma max. 2 com_a data line a 3 0 v reference potential 4 com_b data line b 5 – not used io-link m12 female, 5-pin...

  • Page 18

    Bis v-6107 tcp/ip, usb processor unit 18 figure 5: 61,9 18,5 41,8 68,1 93,1 149 5,3 157,6 +6,0 31 30 5,7 36,4 42,7 4 48,2 168,3 +6,0 dimensions in mm 5.2 mechanical data housing material gd-zn (zinc, die-cast) power 7/8" male, 5-pin, a-coded h1…h4 m12 female, 5-pin, a-coded io-link m12 female, 5-pin...

  • Page 19

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 19 notice exceeding maximum current draw when the maximum current draw is exceeded damage to the processor unit and any connected system components may result. ► ensure that the total current carried through the power terminal does not exceed 8 a...

  • Page 20

    Bis v-6107 tcp/ip, usb processor unit 20 5 technical data ethernet standards 10base-t/100base-tx protocol tcp/ip data rates max. 10/100 mbit/s cable types cat-3 (only 10base-t) cat-5 cable length max. 100 m note for data transmission over longer distances balluff recommends the use of repeaters. Usb...

  • Page 21

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 21 bis v-6107-039-c005/bis v-6107-039-c006 harmonized standards en 61131-2 (immunity) en 61131-2 (emission) en 61000-4-2 – direct contact discharge – severity level 2a – direct air discharge – severity level 3a – indirect contact discharge – seve...

  • Page 22

    Bis v-6107 tcp/ip, usb processor unit 22 6 function indicators the operating states of the identification system, the tcp/ip interface and the io-link master are displayed using leds. Figure 6: function indicators 2 1 3 7 4 6 5 8 9 1 bis v ready (rd) 6 io-link port pin 2 (1) 2 usb connection (usb) 7...

  • Page 23

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 23 led mode display description 0/1 i/o off state of the input or output is 0 yellow state of the input or output is 1 red short circuit on pin 2/pin 4 red, flashing short circuit between pin 1 and 3 (led 0 also flashing red) 0 io-link off disabl...

  • Page 24

    Bis v-6107 tcp/ip, usb processor unit 24 1. Balluff cancel or enter 2. Main ip set. Info cancel (1s) enter cancel 4. Info tag id version enter (1s) 3. Main ip set. Info cancel (1s) enter (1s) cancel (1s) cancel (1s) 5. Id, head 1 e00801d7 e5475d55 cancel 6. Id, head 2 e00801d7 e5475d55 enter display...

  • Page 25

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 25 1. Balluff cancel or enter 2. Main setup info cancel (1s) enter cancel 4. Info tag id version enter (1s) 3. Main setup info cancel (1s) enter cancel 5. Info tag id version enter (1s) 6. Vers. Info fw: 1.00 iol: 010a cancel (1s) 6.6 version dis...

  • Page 26

    Bis v-6107 tcp/ip, usb processor unit 26 balluff 1. 6.7 error list display main setup info 2. 3. Main setup info 4. Info tag id version 5. Info tagid version 6. Info version last error cancel or enter enter enter 1s enter enter enter 1s cancel enter enter cancel 1s cancel 1s enter cancel cancel 1s c...

  • Page 27

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 27 1. Balluff cancel or enter 2. Main ip set. Info cancel 1s enter 1s cancel 1s 4. Ip config static dhcp enter 1s 3. Ip setup ip conf. Ip addr. Cancel 1s ► press enter/down to select the desired configuration. ► pressing cancel (1 s) cancels the ...

  • Page 28

    Bis v-6107 tcp/ip, usb processor unit 28 1. Cancel or enter 2. Cancel 1s enter 1s cancel 1s 3. Enter 1s cancel 1s 5. Enter 1s 4. Cancel 1s enter 1s cancel 1s 6. ► you can switch through the positions (1st, 2nd, 3rd) by pressing enter/down. The current position starts flashing. ► press cancel/up to i...

  • Page 29

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 29 1. Cancel or enter 2. Enter 1s 3. Cancel 1s cancel 1s enter 1s cancel 1s 6. Enter 1s 5. Enter 1s 4. Cancel 1s cancel 1s enter 1s cancel 1s 7. ► you can switch through the positions (1st, 2nd, 3rd) by pressing enter/down. The current position s...

  • Page 30

    Bis v-6107 tcp/ip, usb processor unit 30 6 function indicators 1. Cancel or enter 2. Enter 1s 3. Cancel 1s cancel 1s enter 1s cancel 1s 4. Enter 1s cancel 1s 7. Enter 1s 6. Enter 1s 5. Cancel 1s cancel 1s enter 1s cancel 1s 8. ► you can switch through the positions (1st, 2nd, 3rd) by pressing enter/...

  • Page 31

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 31 7 commissioning to operate the processor unit, including read/write heads and io-link and i/o devices, only power is necessary. External devices are powered by the processor unit. The supply voltage and power supply must meet the requirements ...

  • Page 32

    Bis v-6107 tcp/ip, usb processor unit 32 to open the device properties: ► right-click on cdc data interface – properties to install: 1. Change settings – update drivers . 2. Search for drivers on the computer. 3. After searching navigate to the directory driver on the bis v interchangeable data carr...

  • Page 33

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 33 tip for quick startup the configuration software bis cockpit may also be used. This is available online at www.Balluff.Com . The virtual usb-com-port can be used like a normal serial com port. Connect the pc, for example using a terminal progr...

  • Page 34

    Bis v-6107 tcp/ip, usb processor unit 34 tip for quick startup the configuration software bis cockpit may also be used. This is available online at www.Balluff.Com . The bis v communicates over ethernet tcp/ip sockets with the higher level network. The bis v is assigned an ip address by means of whi...

  • Page 35

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 35 various parameters can be used to affect the behavior of the identification system. A distinction is made here between net parameters, device parameters, rfid parameters and io-link para- meters. This section lists the individual parameters as...

  • Page 36

    Bis v-6107 tcp/ip, usb processor unit 36 only one port is used for connecting to the processor unit. H1…h4 + io-link: port 10001 application example 1 – single-port – r/w heads h1…h4 – io-link application bis v separate tcp ports are used for the connections h1...H4 and io-link. The multi-port socke...

  • Page 37

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 37 if the cp-status parameter is enabled, the processor unit reports asynchronously, i.E. Without any prior request, when a data carrier enters the active field of the read/write head. Depending on the setting of the parameter type and serial num...

  • Page 38

    Bis v-6107 tcp/ip, usb processor unit 38 the crc check is a procedure for determining a check value for data in order to be able to recognize transmission errors. If the crc check is enabled, a status message will be sent when a crc error is detected. Enabled/disabled note the crc check function is ...

  • Page 39

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 39 as soon as the dynamic mode function is enabled, the processor unit accepts the read/write job from the controlling system and stores it, regardless of whether a data carrier is in the active zone of the r/w head or not. If a data carrier ente...

  • Page 40

    Bis v-6107 tcp/ip, usb processor unit 40 data format 2 bytes 2 bytes 2 bytes variable meaning length (number of bytes including length) read/write head type data carrier serial number bis vu-3 _ _ bis vm-3_ _-001-s4 bis vl-3_ _-001-s4 bis c-3 _ _ '04' '03' '02' '01' data carrier types the following ...

  • Page 41

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 41 for read/write heads bis c (with adapter): balluff data carrier type manufacturer memory capacity memory type memory organi- zation bis c-1_ _- 04 balluff 511 bytes eeprom 32-byte blocks bis c-1_ _- 05 balluff 1023 bytes eeprom 32-byte blocks ...

  • Page 42

    Bis v-6107 tcp/ip, usb processor unit 42 determines the cycle time base (milliseconds) with which the minimum cycle time of the io-link communication is calculated. – 0.1 ms – 0.4 ms – 1.6 ms determines the multiplier used to calculate the minimum cycle time of the io-link communica- tion. The facto...

  • Page 43

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 43 specifies whether the parameter data for a connected io-link device are checked after con- necting. If this function is enabled, io-link communication is only started of the parameter data for the io-link device agree with those of the paramet...

  • Page 44

    Bis v-6107 tcp/ip, usb processor unit 44 specifies the device id which is stored in the io-link master. The device id is used with valida- tion for the function parameter server, see parameter parameter server and validation in this section. '000000' specifies the serial number (16-byte ascii coded)...

  • Page 45

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 45 either a usb 1.1 or ethernet tcp/ip connection can be used for communication between the processor unit and the controlling system. Full, errorless and sequenced data transmission is assured by the usb or ethernet transmission channel. Note th...

  • Page 46

    Bis v-6107 tcp/ip, usb processor unit 46 9 protocol multi-level commands are carried out according to the principle base state – request – reply – acknowledgment/data – reply – … – base state : application command status status status acknowledgment/data acknowledgment/data ground state ground state...

  • Page 47

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 47 in addition to the mechanisms for data transmission verification provided by usb and tcp/ip, the user data can be verified using a simple block check character (bcc). The bcc is formed using simple exor operations on all bytes to be sent and i...

  • Page 48

    Bis v-6107 tcp/ip, usb processor unit 48 epc and tid data are sent in blocks of 64 bytes. The length field (1 byte) indicates what length the epc and tid data have (max. 62 bytes). The block may need to be filled flush left with zeros. The epc and tid are output in reverse order with leading zeros (...

  • Page 49

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 49 function command designator description ascii hex type and serial number 'a' 41 hex query information for a selected r/w head – type of connected r/w head – type of data carrier at r/w head – uid/epc/tid of the data carrier type and status 'u'...

  • Page 50

    Bis v-6107 tcp/ip, usb processor unit 50 function command designator description ascii hex no. Of tags 'n' 4e hex query the number of tags located in the range of the specified uhf r/w head detecting data carriers 'm' 4d hex detects the data carriers which are at the specified r/w head and returns a...

  • Page 51

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 51 status number function description '0' 00 hex everything ok '1' 31 hex job cannot be run because there is no data carrier in range of the read/write head. '2' 32 hex cannot read the data carrier. '3' 33 hex data carrier was removed from the r/...

  • Page 52

    Bis v-6107 tcp/ip, usb processor unit 52 command id 'q': cancel ► cancel multi-level commands. A cancel is possible after receipt of any reply. The processor unit returns to the base state after cancel. Byte length command element value range 00 1 command id (ascii) 'q' 01 1 bcc 00 hex …ff hex statu...

  • Page 53

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 53 command id 'z': crc-16 initialize data check ► the memory area of the data carrier used is prepared for use with a crc data check. It is initialized by writing user data with a checksum. ► the number of initialized data is limited to 1024 byte...

  • Page 54

    Bis v-6107 tcp/ip, usb processor unit 54 command id '&': crc-16 initialize data check, expanded ► writes user data at the specified start address. The data length is equal to the number of bytes. ► for jobs > 1024 bytes this command is required. The data are divided into several data blocks and a si...

  • Page 55

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 55 command id 'l': read data carrier ► reads user data from the specified start address. The data length is equal to the number of bytes. ► the number of read data is limited to 1024 bytes. For larger data block use the command read data carrier,...

  • Page 56

    Bis v-6107 tcp/ip, usb processor unit 56 command id 'h': read data carrier, expanded (> 1024 bytes) ► reads user data from the specified start address. The data length is equal to the number of bytes. For jobs > 1024 bytes this read command is needed. ► the data are divided into data blocks of maxim...

  • Page 57

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 57 the reply then follows: byte length command element value range 00 1 control command acknowledgment for the last data packet: byte length command element value range 00 1 status 01 1 number of bytes (ascii) high byte '0'…'9' … … … '0'…'9' 03 1...

  • Page 58

    Bis v-6107 tcp/ip, usb processor unit 58 command id 'p': write data carrier ► writes user data at the specified start address. The data length is equal to the number of bytes. ► the number of write data is limited to 1024 bytes. For larger data blocks use the command write data carrier, expanded . N...

  • Page 59

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 59 command id 'f': write data carrier; expanded ► writes user data at the specified start address. The data length is equal to the number of bytes. For jobs > 1024 bytes this write command is needed. ► the data are divided into data blocks of max...

  • Page 60

    Bis v-6107 tcp/ip, usb processor unit 60 after a successful acknowledgment the data blocks are sent until the required number of blocks has been reached. Byte length command element value range 00 1 control command 01 1 number of bytes (ascii) high byte '0'…'9' … … … '0'…'9' 06 1 number of bytes (as...

  • Page 61

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 61 command id 'c': write data carrier, constant value ► writes a constant value to the memory area, which is indicated with a start address and number of bytes. Byte length command element value range 00 1 command id (ascii) 'c' 01 1 start addres...

  • Page 62

    Bis v-6107 tcp/ip, usb processor unit 62 command id 'd': display output ► output of a predetermined character string on the display. Byte length command element value range 00 1 command id (ascii) 'd' 01 1 number of characters (ascii) high byte '0'…'9' 02 1 number of characters (ascii) low byte '0'…...

  • Page 63

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 63 command id 'c': copy data between data carriers ► copy data from one data carrier to another. The specified number of bytes will be copied from the source start address in the source data carrier to the target start address in the target data ...

  • Page 64

    Bis v-6107 tcp/ip, usb processor unit 64 command id 'q': reset read/write head ► restarts the selected read/write head. Byte length command element value range 00 1 command id (ascii) 'q' 01 1 head number (ascii) '1'…'4' 02 1 bcc 00 hex …ff hex byte length command element value range 00 1 status or ...

  • Page 65

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 65 command id 'a': type and serial number ► read read/write head as well as data carrier type and uid of a data carrier located in the field. Byte length command element value range 00 1 command id (ascii) 'a' 01 1 head number (ascii) '1'…'4' 02 ...

  • Page 66

    Bis v-6107 tcp/ip, usb processor unit 66 command id 'u': type and status ► query information for all r/w heads (h1…h4) – type of connected r/w head – r/w head and tag status – type of data carrier at r/w head – uid/epc/tid of the data carrier if the id of the tag used is there is no tag or more than...

  • Page 67

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 67 the data have the following format: length meaning function description 1 head 1 status status of the 1st head: '0': tag there '1': no tag '9': no head 1 head 1 type '1': c-type '2': l-type '3': m-type '4': u-type 1 head 1 tag type 1 head 1 ta...

  • Page 68

    Bis v-6107 tcp/ip, usb processor unit 68 9 protocol command id 'u': type and status ascii ► query information for all r/w heads (h1…h4) – type of connected r/w head – r/w head and tag status – type of data carrier at r/w head – uid/epc/tid of the data carrier if the id of the tag used is there is no...

  • Page 69

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 69 9 protocol the data have the following format: length meaning function description 1 1 1 head 1 status status of the 1st head: '0': tag there '1': no tag '9': no head hyphen '-' 1 head 1 type (low byte) '01': c-type '02': l-type '03': m-type '...

  • Page 70

    Bis v-6107 tcp/ip, usb processor unit 70 9 protocol length meaning function description 1 head 3 type (low byte) '01': c-type '02': l-type '03': m-type '04': u-type 1 head 3 type (high byte) hyphen '-' 1 head 3 tag type (low byte) tag type in ascii 1 head 3 tag type (high byte) tag type in ascii hyp...

  • Page 71

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 71 9 protocol command id 'v': read version ► one line is output for the processor unit and each r/w head. This shows the product name, firmware version, hardware version and serial number. Unconnected heads are indicated by "no head". Byte length...

  • Page 72

    Bis v-6107 tcp/ip, usb processor unit 72 9 protocol command id '*': digital input, read byte length command element value range 00 1 command id (ascii) '*' 01 1 io-link pin (ascii) '2': pin 2 '4': pin 4 02 1 bcc 00 hex …ff hex acknowledgment: byte length command element value range 00 1 status or 01...

  • Page 73

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 73 9 protocol command id '/': digital output, set byte length command element value range 00 1 command id (ascii) '/' 01 1 io-link pin (ascii) '2': pin 2 '4': pin 4 02 1 value (ascii) '0': on '1': off 03 1 bcc 00 hex …ff hex acknowledgment: byte ...

  • Page 74

    Bis v-6107 tcp/ip, usb processor unit 74 9 protocol command id 'i': read parameter data ► read the io-link parameters. Byte length command element value range 00 1 command id (ascii) 'i' 01 1 index (ascii hex) high byte '0'…'f' … … … '0'…'f' 04 1 index (ascii hex i) low byte '0'…'f' 05 1 sub-index (...

  • Page 75

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 75 9 protocol command id 'y': read cyclical process data ► write io-link process data. Byte length command element value range 00 1 command id (ascii) 'y' 01 1 start address (ascii) high byte '0'…'9' … … … '0'…'9' 03 1 start address (ascii) low b...

  • Page 76

    Bis v-6107 tcp/ip, usb processor unit 76 9 protocol command id 'e': write parameter data ► writes io-link parameters. Byte length command element value range 00 1 command id (ascii) 'e' 01 1 index (ascii hex) high byte '0'…'f' … … … '0'…'f' 04 1 index (ascii hex) low byte '0'…'f' 05 1 sub-index (asc...

  • Page 77

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 77 9 protocol command id 'x': write cyclical process data ► write io-link process data. Byte length command element value range 00 1 command id (ascii) 'x' 01 1 start address (ascii) high byte '0'…'9' … … … '0'…'9' 03 1 start address (ascii) low ...

  • Page 78

    Bis v-6107 tcp/ip, usb processor unit 78 9 protocol note detailed information about the function of read/write head series bis vu* can be found in the manual for the read/write head. Command id 'n': number of tags ► this command returns the number of data carriers that were found in the active read/...

  • Page 79

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 79 9 protocol command id 'm': read data carriers ► the read from multiple data carriers reads, depending on the configured type, the epc or the tid of all data carriers that are located in the active read/write area of the antenna. The epc and ti...

  • Page 80

    Bis v-6107 tcp/ip, usb processor unit 80 9 protocol after errorless reading the data are sent. Byte length command element value range 00 1 status or 01 1 head number (ascii) '1'…'4' 03 1 number of bytes high byte (ascii) '0'…'9' … … … '0'…'9' 05 1 number of bytes low byte (ascii) '0'…'9' 06 1 packe...

  • Page 81

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 81 9 protocol example of a received data frame with 2 epcs and 66 bytes per epc byte data description 00 01 hex antenna port epc 1 01 00 hex reserved 02 0c hex length epc 1 03 00 hex reserved 04…53 00 hex , 00 hex , 00 hex , 00 hex , 00 hex , 00 ...

  • Page 82

    Bis v-6107 tcp/ip, usb processor unit 82 9 protocol command id 'i': read data carrier, bulk ► the bulk read command reads the data from a data carrier population. Optionally from all of the data carriers that are found in the active read/write zone of the antenna or from a subset that was previously...

  • Page 83

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 83 9 protocol the reply then follows: byte length command element value range 00 1 control command if successfully executed the data are sent: byte length command element value range 00 1 status or 01 1 head number (ascii) '1'…'4' 02 1 number of ...

  • Page 84

    Bis v-6107 tcp/ip, usb processor unit 84 9 protocol the data have the following format: length meaning function description 1 data tag 1 [0] transmission of the 1st byte that was read from the 1st data carrier. 1 data tag 1 [1] transmission of the 2nd byte that was read from the 1st data carrier. 1 ...

  • Page 85

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 85 9 protocol command id 'o': read data carrier, epc ► reads the epc memory area of a data carrier that was previously selected with the select command. In single-tag mode, that is, if it can be assured that only one data carrier is located in fr...

  • Page 86

    Bis v-6107 tcp/ip, usb processor unit 86 9 protocol command id 'y': read data carrier, tid ► reads the tid memory area of a data carrier that was previously selected with the select command. In single-tag mode, that is, if it can be assured that only one data carrier is located in front of the activ...

  • Page 87

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 87 9 protocol command id 'w': write to data carrier, bulk ► the bulk write command writes data to a data carrier population. Optionally to all of the data carriers that are found in the active read/write zone of the antenna or from a subset that ...

  • Page 88

    Bis v-6107 tcp/ip, usb processor unit 88 9 protocol byte length command element value range 01 1 number of bytes (ascii) high byte '0'…'9' … … … '0'…'9' 06 1 number of bytes (ascii) low byte '0'…'9' 07 1 data 00 hex …ff hex … … … 00 hex …ff hex last byte 1 bcc 00 hex …ff hex if execution is successf...

  • Page 89

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 89 9 protocol command id 'v': write to data carrier, epc ► writes to the epc memory area of a data carrier that was previously selected with the select command. In single-tag mode, that is, if it can be assured that only one data carrier is locat...

  • Page 90

    Bis v-6107 tcp/ip, usb processor unit 90 9 protocol command id 'k': kill ► the kill command can deactivate a data carrier previously selected with the select com- mand. Note executing the kill command permanently deactivates the selected data carrier. The deactivation cannot be undone. Note in order...

  • Page 91

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 91 9 protocol command id 'l': lock ► the lock command can block read or write access, as well as access of any kind, to memory areas (res, epc, tid, user) of a uhf data carrier. Depending on the level of security, the memory areas can be password...

  • Page 92

    Bis v-6107 tcp/ip, usb processor unit 92 9 protocol lock status of the memory ranges reserved (access-password and kill-password): lock permalock lock status 0 0 read and write: no password 0 1 read and write: (status can not always be changed) no password 1 0 read and write: access password 1 1 rea...

  • Page 93

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 93 9 protocol command id 'g': read parameters ► reads out the parameter values that are currently set in the read/write head. Note the description of the individual parameters and their interpretation can be found in the manual for the bis vu rea...

  • Page 94

    Bis v-6107 tcp/ip, usb processor unit 94 9 protocol command id 'e': write parameters ► the write parameters command transfers parameters to the bis vu read/write head that affect its behavior. Note the description of the individual parameters and their interpretation can be found in the manual for t...

  • Page 95

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 95 9 protocol command id 'r': read rssi ► this command returns the rssi (receive signal strength indicator) which is determined for the selected r/w head. Real-time rssi returns the actual, current rssi value pilot tone rssi returns the rssi valu...

  • Page 96

    Bis v-6107 tcp/ip, usb processor unit 96 9 protocol command id 'z': select (select data carrier in multi-tag mode) ► in the multi-tag mode, the select command selects a single data carrier from within a data carrier population. A data carrier that is located in the active read/write zone of the ante...

  • Page 97

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 97 9 protocol example for entering data carrier data (epc/tid): epc: 01 hex 02 hex 03 hex 04 hex 05 hex 06 hex 07 hex 08 hex 09 hex 10 hex 11 hex 12 hex byte data description 00 0c length epc 1 01 00 reserved 02…51 00 hex , 00 hex , 00 hex , 00 h...

  • Page 98

    Bis v-6107 tcp/ip, usb processor unit 98 command id 'o': read beam power ► reads out the current beam power (erp). The beam power is returned as a value in the form of ¼ dbm. Example: reading out the beam power returns the value of 54 hex (= 84). This corresponds to a beam power of 21 dbm: 84/4 = 21...

  • Page 99

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 99 command id 'p': write beam power ► the beam power for the antenna (erp or eirp), which is specified as a value in ¼ dbm increments, affects the maximum range of the read/write range of the antenna. The maximum beam power depends on the read/wr...

  • Page 100

    Bis v-6107 tcp/ip, usb processor unit 100 command id 'n': unselect (unselecting a data carrier selection) ► the unselect command undoes one data carrier selection that was carried out with the select command. If a selection is not active, the status will remain unchanged. Byte length command element...

  • Page 101

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 101 note all specifications are typical values. Deviations are possible depending on the applica- tion and combination of r/w head and data carrier. The specifications apply to static operation; no crc_16 data checking. All specified read/write t...

  • Page 102

    Bis v-6107 tcp/ip, usb processor unit 102 read times: data carrier with 16 byte blocks bis l-1_ _ data carrier detection ~ 110 ms read bytes 0 to 15 ~ 175 ms for each additional 16-byte block started ~ 40 ms data carrier bis l-2_ _ data carrier detection + read data carrier ≤ 140 ms write times: dat...

  • Page 103

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 103 example: 17 bytes should be written starting at address 187. Data carrier = 32 bytes per block. Blocks 5 and 6 are processed, since the start address 187 is in block 5 and end address 203 is in block 6. T = 2 * 120 + 17 * 10 = 410 read times ...

  • Page 104

    Bis v-6107 tcp/ip, usb processor unit 104 read data carrier at read/write head 1, 2456 bytes user data starting at start address 0. Application bis v command: read data carrier, expanded [data] [data] [data] telegram example: control system 'h' '0' '0' '0' '0' '0' '0' '0' '0' '2' '4' '5' '6' '1' 'r'...

  • Page 105

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 105 processor unit '0' '0' '3' '0' '0' '1' '0' '0' '1' '0' '2' '4' [data] bcc no. Of packets packet number no. Of bytes control system processor unit '0' '0' '3' '0' '0' '2' '0' '0' '1' '2' '4' [data] bcc no. Of packets packet number no. Of bytes...

  • Page 106

    Bis v-6107 tcp/ip, usb processor unit 106 write user data to data carrier a read/write head 1, 5 bytes starting at start address 50. User data: 01 hex 02 hex 03 hex 04 hex 05 hex application bis v command: write to data carrier [data] telegram example: control system 'p' '0' '0' '0' '0' '5' '0' '0' ...

  • Page 107

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 107 processor unit '0' confirm status number control system 01 hex 02 hex 03 hex 04 hex 05 hex 33 hex start command data bcc processor unit '0' confirm status number 9 protocol.

  • Page 108

    Bis v-6107 tcp/ip, usb processor unit 108 write user data to the data carrier at read/write head 1, 5 bytes starting at start address 50. Cancel after first acknowledgment. User data: 01 hex 02 hex 03 hex 04 hex 05 hex application bis v command: write to data carrier command: cancel telegram example...

  • Page 109

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 109 processor unit '0' confirm status number control system 'q' 'q' command designator bcc processor unit '0' confirm status number 9 protocol.

  • Page 110

    Bis v-6107 tcp/ip, usb processor unit 110 epcs of the data carrier located at read/write head 3 are read. Application bis v command: detect data carriers [result] [data] telegram example: control system 'm' '3' 'e' '2' '5' '5' '0' bcc 4d hex 33 hex 45 hex 32 hex 35 hex 35 hex 30 hex 39 hex command d...

  • Page 111

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 111 control system '3' 'e' '0' '0' '1' '6' '4' bcc read/write head no. 3 epc format no. Of data carriers number of bytes per epc control system processor unit '3' '0' '0' '1' '0' '0' '1' '0' '0' '0' '0' '6' '6' [data] bcc read/write head no. 3 no...

  • Page 112

    Bis v-6107 tcp/ip, usb processor unit 112 selecting a certain data carrier at read/write head 1. Epc: 02 hex 03 hex 04 hex 05 hex 06 hex 07 hex 08 hex 09 hex 10 hex 11 hex 12 hex application bis v command: select [result] telegram example: control system 'z' '3' 'e' [data] '0' '0' '0' '0' '0' '0' '0...

  • Page 113

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 113 the bis v-tcp/ip device includes an integrated webserver for retrieving detailed information on the current status. Additionally, this can be used for configuring the ip settings and for setting parameters for devices, head and io-link. For o...

  • Page 114

    Bis v-6107 tcp/ip, usb processor unit 114 here the information for the processor unit configuration is shown. The device image is dynamic. The animated leds correspond to the current device status. If an rfid r/w head or an io-link-device is connected to the respective ports, then additional informa...

  • Page 115

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 115 the link "led legend" opens a window with a short explanation of the individual leds. The parameter settings of the selected module (r/w heads) are shown on this page. Each module can be selected separately. Io-link modules can also be config...

  • Page 116

    Bis v-6107 tcp/ip, usb processor unit 116 here the io-link device connected to the io-link port is shown/entered. The io-link device can be parameterized on this page. The setup is divided into three parts: network, modules and rfid. This function can only be used after a successful login. Password:...

  • Page 117

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 117 ip-control can be used to specify whether the ip address is automatically assigned via dhcp or manually (static). Factory resets the ip address to the factory default setting 192.168.72.223. Clicking on the save configuration button saves the...

  • Page 118

    Bis v-6107 tcp/ip, usb processor unit 118 on this page you can set the parameters for the selected head. Exit the expanded functions "setup/*“: ► click on the "logout" button in the navigation line. Rfid logout 10 webserver.

  • Page 119

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 119 display of the contact data for balluff and legend for the navigation elements in the menu line. Info 10 webserver.

  • Page 120

    Bis v-6107 tcp/ip, usb processor unit 120 bis v – 6 1 07 – 048 – c005 balluff identification system series v (v = variable) system component 6 = processor unit generation (design/material) 1 = generation 1, 2011 housing design, metal interface 07 = tcp/ip, usb software type 039 = ethernet tcp/ip con...

  • Page 121

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 121 decimal hex control code ascii decimal hex ascii decimal hex ascii 0 00 ctrl @ nul 43 2b + 86 56 v 1 01 ctrl a soh 44 2c , 87 57 w 2 02 ctrl b stx 45 2d - 88 58 x 3 03 ctrl c etx 46 2e . 89 59 y 4 04 ctrl d eot 47 2f / 90 5a z 5 05 ctrl e enq...

  • Page 122

    Bis v-6107 tcp/ip, usb processor unit 122 index a abbreviations 6 dimensions 18 connections ethernet tcp/ip 20 h1...H4 19 io-link 19 usb 20 ascii table 112 processor unit installation 14 auto-read length 31 auto-read start address 31 b meaning of warning notes 5 commands bis vu 44 global 42 , 43 io-...

  • Page 123

    Www.Balluff.Com bis v-6107 tcp/ip, usb processor unit 123 s read/write heads h1…h4 11 read/write head status 22 spellings 5 write times 93 select 103 serial 38 setup 107 safety 7 , 88 operation 7 commissioning 7 installation 7 single-port 30 slow tag detection 35 software and accessories 10 power su...

  • Page 124: Www.Balluff.Com

    No. 933434-726 en · c17; subject to modifications. Www.Balluff.Com headquarters germany balluff gmbh schurwaldstrasse 9 73765 neuhausen a.D.F. Phone + 49 7158 173-0 fax +49 7158 5010 balluff@balluff.De global service center germany balluff gmbh schurwaldstrasse 9 73765 neuhausen a.D.F. Phone +49 715...