Summary of BNI IOL-102-000-Z012

  • Page 1

    Bni iol-102-000-z012 bni iol-104-000-z012 bni iol-104-s01-z012 bni iol-104-s01-z012-c01 bni iol-104-s01-z012-c02 bni iol-302-000-z012 bni iol-302-s01-z012 bni iol-302-000-z042 user´s guide.

  • Page 2

    Www.Balluff.Com 1 inhalt 1 notes for the user 2 1.1. About this guide 2 1.2. Structure of the guide 2 1.3. Typographical conventions 2 enumerations 2 actions 2 syntax 2 cross references 2 1.4. Symbols 2 1.5. Abbreviations 2 2 safety 3 2.1. Intended use 3 2.2. Installation and startup 3 2.3. General ...

  • Page 3

    Balluff network interface / io-link bni iol- ….. -z0xx www.Balluff.Com 2 1 notes for the user 1.1. About this guide this guide describes the balluff network interface bni iol- …-z0xx for the application as peripheral output module to establish connection of binary actuators. Hereby it is about an io...

  • Page 4

    Www.Balluff.Com 3 2 safety 2.1. Intended use this guide describes the balluff network interface bni iol- …… for the application as peripheral output module to establish connection of binary actuators. Hereby it is about an io-link device which communicates by means of io-link protocol with the super...

  • Page 5

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 4 3 getting started 3.1. Connection overview fig. 3-1: bni iol- …..-z0xx 1 mounting hole 2 label 3 status led:communication / module 4 standard i/o port 1 5 standard i/o port 3 6 standard i/o port 5 7 standard i/o port 7 8 mountin...

  • Page 6

    Www.Balluff.Com 5 3 getting started 3.2. Mechanical connection the bni iol- …..-z0xx modules are attached by using 2 m6 screws and 2 spacers. 3.3. Electrical connection the bni iol- …-z0xx modules require no separate supply voltage connection. Power is provided through the io-link interface by the h...

  • Page 7

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 6 3 getting started 3.4. Sensor interface standard i/o port (m12, a-coded, female) m12 a- coded female pin function input pin4 input pin4/pin2 output in / out 1 +24v 0.1 a +24v 0.1 a n.C. +24v 0.1 a 2 n. C. Input output 500 ma / 2...

  • Page 8

    Www.Balluff.Com 7 4 io-link interface 4.1. Io-link data bni iol-102-000-z012 data transmission rate com2 (38,4 kbaud) minimal cycle time 3 ms process data length 1 byte input io-link revision 1.0 process data cycle time 3 ms, minimal cycle time bni iol-104-000-z012 data transmission rate com2 (38,4 ...

  • Page 9

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 8 4 io-link interface bni iol-302-000-z012 data transmission rate com2 (38,4 kbaud) minimal cycle time 3 ms process data length 2 byte input, 2 byte output io-link revision 1.0 process data cycle time 12 ms, minimal cycle time bni...

  • Page 10

    Www.Balluff.Com 9 4 io-link interface 4.2. Prozess data/ input data bni iol-102-000-z012 byte 0 bit 7 6 5 4 3 2 1 0 des c ri p tio n in p u t p o rt 7 p in 4 in p u t p o rt 6 p in 4 in p u t p o rt 5 p in 4 in p u t p o rt 4 p in 4 in p u t p o rt 3 p in 4 in p u t p o rt 2 p in 4 in p ut p o rt 1 ...

  • Page 11

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 10 4 io-link interface bni iol-104-s01-z012 byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 des c ri p tio n in p u t p o rt 7 p in 4 in p u t p o rt 6 p in 4 in p u t p o rt 5 p in 4 in p u t p o rt 4 p in 4 in p u t p o rt 3 p in 4...

  • Page 12

    Www.Balluff.Com 11 4 io-link interface bni iol-104-s01-z012-c01 bni iol-104-s01-z012-c02* byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 des c ri p tio n in p u t p o rt 7 p in 4 in p u t p o rt 6 p in 4 in p u t p o rt 5 p in 4 in p u t p o rt 4 p in 4 in p u t p o rt 3 p in 4 in p u t p o rt 2 p in ...

  • Page 13

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 12 4 io-link interface bni iol-302-s01-z012 byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 des c ri p tio n in p u t p o rt 7 p in 4 in p u t p o rt 6 p in 4 in p u t p o rt 5 p in 4 in p u t p o rt 4 p in 4 in p u t p o rt 3 p in 4...

  • Page 14

    Www.Balluff.Com 13 4 io-link interface 4.3. Prozess data / output data bni iol-302-xxx-z0xx byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 des c ri p tio n ou tp u t p o rt 7 p in 4 ou tp u t p o rt 6 p in 4 ou tp u t p o rt 5 p in 4 ou tp u t p o rt 4 p in 4 ou tp u t p o rt 3 p in 4 ou tp u t p o rt...

  • Page 15

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 14 4 io-link interface parameter data / request data dpp spdu object name length range default value index index sub- index id e nti fic a ti on d a ta 07 hex vendor id 2 byte r e a d o n ly 0378 hex 08 hex 09 hex device id 3 byte...

  • Page 16

    Www.Balluff.Com 15 4 io-link interface pa ram e te r dat a dpp spdu object name length range default value index index sub- index 40 hex 0 1-16 inversion 2 byte 0hex …ffffhex 0000 hex 41 hex 0 1-16 port direction* 2 byte 0 hex … ffff hex 0000 hex 42 hex 0 1-8 fault state pin4* 2 byte 0 hex … ffff he...

  • Page 17

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 16 4 io-link interface inversion of the inputs 40 hex bni iol-10x-xxx-z012 bni iol-104-s01-z012-c0x bni iol-302-xxx-z0xx byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub index 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 d e s c ri pt i...

  • Page 18

    Www.Balluff.Com 17 4 io-link interface fault state of the outputs pin 4, 42 hex bni iol-302-xxx-z0xx byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub index 4 3 2 1 8 7 6 5 d e s c ri pt ion fau lt s ta te p o rt 3 p in 4 fau lt s ta te p o rt 2 p in 4 fau lt s ta te p o rt 1 p in 4 fau lt s ta te p ...

  • Page 19

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 18 4 io-link interface voltage monitoring 44 hex bni iol-x0x-xxx-z012 bni iol-104-s01-z012-c0x byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub index 16 15 14 13 12 11 10 9 3 1 des c ripti on s h o rt c irc u it p o rt 7 s h o rt ...

  • Page 20

    Www.Balluff.Com 19 4 io-link interface identification 60hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 des c ri p tio n identification byte 0* identification byte 1* byte 2 3 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 des c ri p tio n identification byte 2** identification byte 3** *only in case of bni i...

  • Page 21

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 20 5 technical data 5.1. Dimensions 5.2. Mechanical data housing material die-cast zinc housing io-link-port m12, a-coded, male i/o-ports m12, female, 5-poles enclosure rating per iec 60529 ip67 (only when plugged in and threaded ...

  • Page 22

    Www.Balluff.Com 21 5 technical data 5.5. Led indicators status leds bni iol-10x-xxx-z012 led indicator function led 1 green / red supply sensors & module ok / undervoltage led 6 green / green flashing communication error / communication ok bni iol-302-xxx-z0xx led indicator function led 1 green / re...

  • Page 23

    Balluff network interface / io-link bni iol- …… -z0xx www.Balluff.Com 22 6 appendix 6.1. Product ordering code bni iol-x0x-xxx-z0xx-c0x balluff network interface io-link interface functions 102 = 8 dig. Inputs 104 = 16 dig. Inputs 302 = 16 dig. Inputs / outputs versions 000 = standard version s01 = ...

  • Page 24: Www.Balluff.Com

    Www.Balluff.Com www.Balluff.Com balluff gmbh schurwaldstrasse 9 73765 neuhausen a.D.F. Germany tel. +49 7158 173-0 fax +49 7158 5010 balluff@balluff.De nr. 8 9 2 9 3 1 e ed iti o n 1 4 0 4 rep la c e s e d it io n 12 10 s u b je c t to m o d ifi c a ti o n.