3
Getting Started
3.2. Mechanical
connection
The modules BNI IOL-25x-xxx-Z013 are attached by using 2 M6 screws and 2 spacers.
3.3. Electrical
connection
The BNI IOL-25x modules have a separate supply voltage connection. Power is provided
through the 7/8” male plug. The module is divided into two segments. 4 or 8 outputs
respectively can be switched for each segment. The segments are galvanic isolated from
each other.
The connection of communication takes place through the IO-Link interface. Power for the
IO-Link interface is provided by the host IO-Link Master directly and it is galvanic isolated
from the supply voltage of both output segments.
Power supply of
the outputs
Power IN (7/8”, male)
Pin
Function
1
GND, reference potential segment 1
2
GND, reference potential segment 2
3
FE, Function earth
4
+24V, power supply, outputs segment 2
5
+24V, power supply, outputs segment 1
Function ground
Note
The FE connection from the housing to the machine must be low-impedance and
kept as short as possible.
IO-Link interface
IO-Link (M12, A-coded, male)
Pin
Function
1
Power supply controller, +24V, max 1,1A
2
-
3
GND, Reference potential
4
C/Q, IO-Link data transmission channel
Connecting the
actuator hub
Connection protection ground to FE terminal, if present.
Connecting the power supply of the segments.
Connect the incoming IO-Link line to the actuator hub.