Bni iol-302-002-e012 io-link 1.1 sensor/actuator hub with extension port user's guide.
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 2 contents 1 general 4 1.1. Structure of the manual 4 1.2. Typographical conventions 4 enumerations 4 actions 4 syntax 4 cross-references 4 1.3. Symbols 4 1.4. Abbreviations 4 1.5. Deviating views 4 2 safety 5 2.1. Intended use...
Www.Balluff.Com 3 setting the serial number 54hex 22 7 configuration extended with valve terminal connector with 22/24 valves 23 7.1. Io-link data 23 7.2. Process data/input data 23 7.3. Process data/ output data 24 7.4. Parameter data / demand data 25 inversion of the inputs 40hex 26 configuration ...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 4 1 general 1.1. Structure of the manual the manual is organized so that the sections build on one another. Chapter 2: basic safety information. …….. 1.2. Typographical conventions the following typographical conventions are us...
Www.Balluff.Com 5 2 safety 2.1. Intended use the bni iol-… acts as a decentralized input/output sensor module, which is connected to a higher-level io-link master module through an io-link interface. 2.2. Installation and startup attention! Installation and startup must only be carried out by traine...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 6 3 first steps 3.1. Connection overview figure 3-1: connection overview bni iol-302-002-e012 1 mounting hole/ground 2 status led: communication 3 port 1 4 port 3 5 port 5 6 port 7, extension port 7 pin/port led: signal status ...
Www.Balluff.Com 7 3 first steps 3.2. Mechanical connection the bni iol modules are attached using 2 m6 screws and 2 washers. 3.3. Electrical connection the modules do not require a separate supply voltage connection. Supply voltage is provided via the io-link interface and the higher-level io-link m...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 8 3 first steps connecting the sensor hub connect ground conductor to the functional ground connection, if available. Connect the incoming io-link cable to the sensor hub. Note a standardized sensor cable is used to connect to ...
Www.Balluff.Com 9 4 general configuration the modules gives you the ability to use the no. 7 slot in various ways. By default, it is used as a digital input slot, where both pin 2 and pin 4 can be used as a digital input. This slot can be used as an extension port by making a corresponding entry in ...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 10 5 configuration: "extension off" 5.1. Io-link data bni iol-302-002-e012 extension off transmission rate com2 (38.4 kbaud) minimum cycle time 4.0 ms process data length 2 byte input, 2 byte output 5.2. Process data/input data...
Www.Balluff.Com 11 5 configuration: "extension off" 5.4. Parameter data / demand data dpp spdu parameter data width access rights default value index index sub- index ident if ic at ion dat a 07 hex 07 vendor id 2 bytes r ea d on ly 0378 hex 08 hex 08 09 hex 09 device id 3 bytes 0x05 0d 80 0a hex 10...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 12 5 configuration: "extension off" inversion of the inputs 40 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 d es cri pt ion in ve rs ion o f p or t 7 p in 4 in ve rs ion o f...
Www.Balluff.Com 13 5 configuration: "extension off" safe state of the outputs on pin 4 42 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 4 3 2 1 8 7 6 5 d es cri pt ion s af e st at e p or t 3 p in 4 s af e st at e p or t 2 p in 4 s af e st at e p or t 1 p in 4 s af e st at e p or t 0 p...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 14 5 configuration: "extension off" monitoring the outputs 45 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 d es cri pt ion s ho rt -c irc uit p or t 7 p in 4 s ho rt -c irc ...
Www.Balluff.Com 15 6 configuration: extended with bni iol-302-002-e012 6.1. Io-link data bni iol-302-002-e012 extended with bni iol-302-002-e012 transmission rate com2 (38.4 kbaud) minimum cycle time 5.0 ms process data length 4 bytes input, 4 bytes output 6.2. Process data/input data byte 0 1 bit 7...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 16 6 configuration: extended with bni iol-302-002-e012 6.3. Process data/ output data byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 d es cri pt ion - ou tp ut p or t 6 p in 4 ou tp ut p or t 5 p in 4 ou tp ut p or t 4 p in 4 ou ...
Www.Balluff.Com 17 6 configuration: extended with bni iol-302-002-e012 6.4. Parameter data / demand data dpp spdu parameter data width access rights default value index index sub- index ident if ic at ion dat a 07 hex 7 vendor id 2 bytes r ea d on ly 0378 hex 08 hex 8 09 hex 9 device id 3 bytes 0x05...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 18 6 configuration: extended with bni iol-302-002-e012 inversion of the inputs 40 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 d es cri pt ion - in ve rs ion o f p or t 6 p ...
Www.Balluff.Com 19 6 configuration: extended with bni iol-302-002-e012 configuration of inputs/outputs 41hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 7 6 5 4 3 2 1 15 14 13 12 11 10 9 d es cri pt ion - d ire ct ion p or t 6 p in 4 d ire ct ion p or t 5 p in 4 d ire ct ion p or t 4 p i...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 20 6 configuration: extended with bni iol-302-002-e012 safe state of the outputs on pin 4 42 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 4 3 2 1 7 6 5 d es cri pt ion s af e st at e p or t 3 p in 4 s af e st at ...
Www.Balluff.Com 21 6 configuration: extended with bni iol-302-002-e012 safe state of the outputs on pin 2 43 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 4 3 2 1 8 7 6 5 d es cri pt ion s af e st at e p or t 3 p in 2 s af e st at e p or t 2 p in 2 s af e st at e p or t 1 p in 2 s af e...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 22 6 configuration: extended with bni iol-302-002-e012 voltage monitoring 44 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 8 7 6 5 4 3 2 1 12 11 9 d es cri pt ion s ho rt -c irc uit p or t 7 p in 1 s ho rt -c irc ...
Www.Balluff.Com 23 7 configuration extended with valve terminal connector with 22/24 valves 7.1. Io-link data bni iol-302-002-e012, extended with valve terminal connector with 22/24 valves transmission rate com2 (38.4 kbaud) minimum cycle time 5.1 ms process data length 2 byte input, 6 byte output 7...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 24 7 configuration extended with valve terminal connector with 22/24 valves 7.3. Process data/ output data byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 d es cri pt ion ou tp ut p or t 7 p in 4 ou tp ut p or t 6 p in 4 ou tp ut ...
Www.Balluff.Com 25 7 configuration extended with valve terminal connector with 22/24 valves 7.4. Parameter data / demand data dpp spdu parameter data width access rights default value index index sub- index ident if ic at ion dat a 07 hex 07 vendor id 2 bytes r ea d on ly 0378 hex 08 hex 08 09 hex 0...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 26 7 configuration extended with valve terminal connector with 22/24 valves inversion of the inputs 40 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 d es cri pt ion - in ve r...
Www.Balluff.Com 27 7 configuration extended with valve terminal connector with 22/24 valves safe state of outputs 42 hex the safe state parameter makes it possible to configure the outputs in case of a fault. If no io-link communication is possible or the "valid flag" of the output process data has ...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 28 7 configuration extended with valve terminal connector with 22/24 valves byte 6 7 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 24 22 20 18 valve terminal on extension port d es cri pt ion - - - - * v al ve 1 2 – c oil b v ...
Www.Balluff.Com 29 7 configuration extended with valve terminal connector with 22/24 valves voltage monitoring 44 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 8 7 6 5 4 3 2 1 12 11 9 d es cri pt ion s ho rt -c irc uit p or t 7 p in 1 s ho rt -c irc uit p or t 6 p in 1 s ho rt -c irc u...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 30 7 configuration extended with valve terminal connector with 22/24 valves monitoring the outputs 45 hex byte 0 1 bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 sub- index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 d es cri pt ion s ho rt -c...
Www.Balluff.Com 31 7 configuration extended with valve terminal connector with 22/24 valves 7.5. Errors error code description 0x8011 index not available 0x8012 subindex not available 0x8023 access denied 0x8033 parameter length overrun 0x8034 parameter length underrun 0x8035 function not available ...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 32 8 io-link functions 8.1. Io-link version 1.0 / 1.1 this device can be operated with an io-link master according to io-link version 1.0 and version 1.1. Version-specific functions such as data storage (version 1.1) are only s...
Www.Balluff.Com 33 9 technical data 9.1. Dimensions 9.2. Mechanical data housing material stainless steel (v4a) io-link port io-link port m12, a-coded, male i/o ports m12x1, a-coded, female (8 piece) weight ca 530 g dimensions (l×w×h) 181.6 × 70 × 37.9 mm 9.3. Electrical data operating voltage 18–30...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 34 10 function indicators 10.1. Function indicators led indicator module status indicator function com green no communication green, negative pulsed communication ok us1 led green module supply ok red undervoltage ua led green ...
Www.Balluff.Com 35 10 function indicators digital led indicators for inputs/outputs led 2, input/output on pin 4 and led 1, input/output on pin 2 indicator request / signal yellow input/output signal = 1 red sensor supply short-circuit off input/output signal = 0 extension port the table is valid if...
Balluff network interface / io-link bni iol-302-002-e012 www.Balluff.Com 36 11 appendix 11.1. Type code 11.2. Ordering information type code order code bni iol-302-002-e012 bni00ar bni iol-302-002-e012 balluff network interface io-link interface functions 302 = 16 inputs/outputs variants 002 = with ...
Www.Balluff.Com 37 notes.
Www.Balluff.Com www.Balluff.Com balluff gmbh schurwaldstrasse 9 73765 neuhausen a.D.F. Germany phone +49 7158 173-0 fax +49 7158 5010 balluff@balluff.De no . 9 3 16 9 9 e ed iti on j 16 s u b je ct to m od ifi ca tio n.