Balluff BNI PNT-502-105-Z015 User manual

Manual is about: IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs

Summary of BNI PNT-502-105-Z015

  • Page 1

    Bni pnt-502-105-z015 ip67 modules 4 io-link/in-/outputs,12 in-/outputs user’s guide.

  • Page 2

    Www.Balluff.Com 1 content 1 notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical conventions 3 enumerations 3 actions 3 syntax 3 cross-references 3 1.4. Symbols 3 1.5. Abbreviations 3 2 safety 4 2.1. Intended use 4 2.2. General safety notes 4 2.3. Meaning of the warnings ...

  • Page 3

    Www.Balluff.Com 2 content 7 appendix 16 7.1. Included material 16 7.2. Ordercode 16 7.3. Order information 16.

  • Page 4

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 3 1 notes 1.1. About this guide the bni pnt- … serves as a decentralized io-link, input and output module for connecting to an profinet ™ network. 1.2. Structure of the guide the guide is organized so that the chapters build on...

  • Page 5

    Www.Balluff.Com 4 2 safety 2.1. Intended use this guide describes the bni pnt- … serves as a decentralized io-link, input and output module for connecting to an profinet ™ network. 2.2. General safety notes installation and startup are to be performed only by trained specialists. Any damage resultin...

  • Page 6

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 5 3 getting started 3.1. Modul overview figure 1 – overview bni pnt-502-105-z015 1 mounting hole 2 profinet ™ port 2 3 display 4 power supply in 5 status led 6 port 1 (standard i/o) 7 pin/port led: signal status 8 port 3 (stand...

  • Page 7

    Www.Balluff.Com 6 3 getting started 3.2. Mechanical connection the module is attached using 2 m6 screws and 2 washers. Isolation pad as accessory available 3.3. Electrical connection power supply power supply “in” (7/8”, male) pin function description 1 gnd actuator power supply 0 v 2 gnd bus- / sen...

  • Page 8

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 7 3 getting started i/o-port m12, a-coded, female pin function 1 +24v, 200ma 2 input / output 3 gnd 4 input / output 5 fe note! For the digital sensor inputs follow the input guideline per en61131-2, type 2. Note! Each output s...

  • Page 9

    Www.Balluff.Com 8 4 technical data 4.1. Dimensions 4.2. Mechanical data housing material die case zinc, matt nickel plated enclosure rating per iec 60529 ip 67 (only when plugged-in and threaded-in) supply voltage 7/8” 5-pin male input ports / output ports m12, a-coded (8 x female) dimensions (w x h...

  • Page 10

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 9 4 technical data 4.5. Profinet profinet port 1 x 10base-/100base-tx connection for profinet port m12, d-coded cable types per ieee 802.3 shielded twisted pair min. Stp cat 5/ stp cat 5e data transmission rate 10/100 mbit/s ma...

  • Page 11

    Www.Balluff.Com 10 5 integration 5.1. Configuration when project planning profibus devices, a device is mapped as a modular system which consists of a header module and multiple data modules. Gsdml-file the device data required for project planning are stored in gsdml files (generic station descript...

  • Page 12

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 11 5 integration including the module to configuration object properties.

  • Page 13

    Www.Balluff.Com 12 5 integration naming of the device configuration of the ethernet address.

  • Page 14

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 13 5 integration finish hardware configuration integration to the profinet network.

  • Page 15

    Www.Balluff.Com 14 5 integration scanning the system succesfully integrated in the system selection of the device names mac id of the device mac id of the device assigned device name.

  • Page 16

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 15 6 webserver 6.1. General the bni pnt-502 module includes an internal webserver to get detailed information about the current state. Also you can use it to configurate the module and the connected io-link devices. First make ...

  • Page 17

    Www.Balluff.Com 16 7 appendix 7.1. Included material the bni pnt consists of the following components: • io-link block • 4 blind plugs m12 • ground strap • screw m4x6 • 20 labels 7.2. Ordercode bni pnt-502-105-z015 balluff network interface profinet functions 502 = ip 67 io-link master-modul variant...

  • Page 18

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 17 notes.

  • Page 19

    Www.Balluff.Com 18 notes.

  • Page 20: Www.Balluff.Com

    Balluff network interface profinet, bni pnt-502-105-z015 www.Balluff.Com 19 www.Balluff.Com balluff gmbh schurwaldstrasse 9 73765 neuhausen a.D.F. Germany tel. +49 7158 173-0 fax +49 7158 5010 balluff@balluff.De nr. 8 8 3 2 2 0 e ed iti o n 1 1 0 9 rev is e d ed iti o n 1 1 0 3 su b je c t to m o d ...