Banner DF-G1-KS-2M Installation Manual

Manual is about: Dual Display Fiber Amplifier

Summary of DF-G1-KS-2M

  • Page 1

    Installation guide advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies. For complete technical information about this product, including dimensions, accessories, and specifications, see banner engineering website. Overview figure 1. Df-g1 model features 1...

  • Page 2

    Installation instructions mounting instructions mount on a din rail 1. Hook the din rail clip on the bottom of the df-g1 over the edge of the din rail (1). 2. Push the df-g1 up on the din rail (1). 3. Pivot the df-g1 onto the din rail, pressing until it snaps into place (2). Mount to the accessory b...

  • Page 3

    Fiber adapters note: if a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder. Banner includes the adapters with all fiber assemblies. To fibers to sensor fiber outer diameter (mm) adapter co...

  • Page 4

    Io-link models (c/q) (q) push-pull 18-30v dc load load note: open lead wires must be connected to a terminal block. Top panel interface opening the dust cover provides access to the top panel interface. The top panel interface consists of the run/prg/adj mode switch, lo/do switch, +/set/- rocker but...

  • Page 5

    Run mode run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/set/- rocker button is disabled during run mode, except when using window set, see window set on page 10. Df-g1 expert ™ dual display fiber amplifier phone: 800.894.0412 - fax: 888.723.4773 ...

  • Page 6

    Program mode program (prg) mode allows the following settings to be programmed in the df-g1: factory default settings: setting factory default threshold 2026 teach selection two-point teach response speed standard - 500 µs offset percent 10% auto thresholds off off delay 0 (disabled) off one-shot 0 ...

  • Page 7

    Adjust mode sliding the run/prg/adj mode switch to the adj position allows the user to perform expert teach/set methods and manual adjustment of the threshold(s). Two-point teach • establishes a single switching threshold • threshold can be adjusted using "+" and "-" rocker button (manual adjust) tw...

  • Page 8

    Method action result set button a. Present the first condition. B. Click the set rocker button display: flashes "2pt tch" then holds on "1234 2nd" remote input a. Present the first condition. B. Single-pulse the remote input. T 3. Teach the second condition. Method action result set button a. Presen...

  • Page 9

    Sensor positions threshold midway between taught conditions darkest (no signal) most light (saturated signal) output off output on darkest taught condition lightest taught condition position adjusted by manual adjust figure 3. Dynamic teach (light operate shown) the output on and off conditions can ...

  • Page 10

    Method action result set button present on and off conditions display: red - signal level; green - threshold remote input present on and off conditions 4. Exit dynamic teach. Method action result set button click the set rocker button teach accepted displays alternate "pass" with % minimum differenc...

  • Page 11

    Sensor positions window thresholds a programmable % offset from the presented condition darkest (no signal) most light (saturated signal) condition presented sensing window center adjusted by manual adjust output off output off output on figure 4. Window set (light operate shown) output on and off c...

  • Page 12

    Method action result set button • present sensing condition • click the set rocker button threshold condition accepted displays read "wind set" then alternate "pass" with % offset10; sensor returns to adjust mode threshold condition not accepted displays read "wind set" then alternate "fail" with mi...

  • Page 13

    Threshold position adjusted by manual adjust sensor positions threshold a programmable % offset below the presented condition darkest (no signal) most light (saturated signal) output off output on condition presented figure 6. Light set (light operate shown) light set and manual adjust moves switchi...

  • Page 14

    Method action result set button • present sensing condition • click the set rocker button threshold condition accepted displays read "lt set" then alternate "pass" with % offset13; sensor returns to adjust mode threshold condition not accepted displays read "lt set" then alternate "fail" with minimu...

  • Page 15

    Sensor positions threshold a programmable % offset above the presented condition threshold position adjusted by manual adjust darkest (no signal) most light (saturated signal) output off output on condition presented figure 7. Dark set (light operate shown) dark set and manual adjust moves switching...

  • Page 16

    Method action result set button • present sensing condition • click the set rocker button threshold condition accepted displays read "dr set" then alternate "pass" with % offset16; sensor returns to adjust mode threshold condition not accepted displays read "dr set" then alternate "fail" with minimu...

  • Page 17

    ◦ green display shows the switching threshold value ◦ 2 seconds after adjustment, the green display will flash 3 times to confirm • slide mode switch to run to complete operation remember: auto thresholding is automatically disabled in calibration set follow these steps to perform a calibration set:...

  • Page 18

    Troubleshooting manual adjustments disabled manual adjustments are disabled when auto thresholds are on. If a manual adjustment is attempted while auto thresholds are on, the green display will flash . Percent minimum difference after teach the two-point and dynamic teach methods will flash a % mini...

  • Page 19

    Specifications sensing beam 660 nm visible red supply voltage npn/pnp models: 10 to 30 v dc class 2 (10% max ripple) io-link models: 18 to 30 v dc (10% max ripple) power and current consumption (exclusive of load) standard display mode: 960 mw, current consumption 24 v dc eco display mode: 720 mw, c...