    Supply voltage: 10 to 30v dc at less than 20 milliamps (ex- clusive of load); 10% maximum ripple. Output configuration: two open-collector npn (current sinking) transistor (solid-state) switches; one normally open (light operate) and one normally closed (dark operate); 150 milliamps maxi- mum, each ...

  • Page 2

    Models sp100c and ccf are ideally suited to applications where depth of field is critical. The emitter and receiver are both directed at a point 0.1 inch (2,5mm) ahead of the front surface. An aperture is included which, when attached, nar- rows the depth of field (see curves, below). This is partic...

  • Page 3: Micro-Amp

    Beam pattern 3 dimensions, tr-100 mounting track "a" di- mension 1" (25mm) 4" (10cm) 6" (15cm) 12" (30cm) minimum number of slots 1 2 3 8 track model tr100-1 tr100-4 tr100-6 tr100-12 pvc mounting track for micro-amp components is available in 6 and 12 inch lengths for systems which use multiple comp...

  • Page 4: Other Micro-Amp

    Banner engineering corp. 9714 10th ave. No., minneapolis, mn 55441 telephone: (763) 544-3164 fax (applications): (763) 544-3573 warranty: banner engineering corporation warrants its products to be free from defects for one year. Banner engineering corporation will repair or replace, free of charge, ...