    Quick start guide laser expert ™ diffuse sensor with bipolar (1 pnp & 1 npn) output. Patent pending. This guide is designed to help you set up and install the q3x sensor. For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the instructi...

  • Page 2

    A displayed value of indicates no light received or a loss of signal. In window set teach mode, the value 100 represents the taught signal strength. The displayed value is the percentage of the received light divided by the taught signal strength. The output switches at displayed values above and be...

  • Page 3

    Laser description and safety information caution: use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not attempt to disassemble this sensor for repair. A defective unit must be returned to the manufacturer. Las...

  • Page 4

    Wiring diagram 3 1 2 4 5 10-30v dc input wire load load + – note: open lead wires must be connected to a terminal block. 1 4 5 3 2 key 1 = brown 2 = white 3 = blue 4 = black 5 = gray note: the input wire function is user-selectable; see the instruction manual for details. The default for the input w...

  • Page 5

    1. Press and hold teach for longer than 2 seconds to start the selected teach mode. 2. Present the target. 3. Press teach to teach the target. The target is taught and the sensor waits for the second target, if required by the selected teach mode, or returns to run mode. Complete steps 4 and 5 only ...

  • Page 6

    Q3xtbld50 models (a 6% black card sensing cut-off distance will be 95% of a 90% reflective white card.) distance (mm) excess gain 1 1 10 10 100 100 1000 figure 7. Excess gain for standard sensitivity distance (mm) 0 10 20 30 40 50 bea m p attern (mm) -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5 figure 8. Beam pat...

  • Page 7

    Input wire allowable input voltage range: 0 to vcc active low (internal weak pullup—sinking current): low state output configuration bipolar (1 pnp & 1 npn) output output rating discrete output: 100 ma maximum (protected against continuous overload and short circuit) off-state leakage current: npn o...

  • Page 8

    Sensor menu map no: do not reset to factory defaults yes: reset to factory defaults two-point static teach dynamic teach light set window set top menu sub menu off: no delays enabled on: enable on and/or off delay (set value in delay timer menu) 1 shot, fixed output pulse duration lo = single fixed ...