Banner TCNM-AD Quick Start Manual

Summary of TCNM-AD

  • Page 1

    Quick start guide general view 1 2 5 6 7 4 3 1 = laser beam output window 2 = power on led 3 = warning and device class labels 4 = accessory mounting holes 5 = mounting holes 6 = leds 7 = push button note: the quick start guide describes stand-alone application. For other types of installations, suc...

  • Page 2

    Barcode scanner host trigger * presence sensor (for on-line mode) main i/o, aux tcnm-acbb1 figure 1. Barcode scanner in a standalone layout tcnm-acbb1 pinout the table below gives the pinout of the tcnm-acbb1 terminal block connectors. Use this pinout when the barcode scanner is connected using the ...

  • Page 3

    Tcnm-acbb1 terminal block connectors rx 1 rx+ cts 1 rx– sgnd sgnd sgnd caution: do not connect gnd, sgnd, and ref to different (external) ground references. Gnd, sgnd, and ref are internally connected through filtering circuitry that can be permanently damaged if subjected to voltage drops over 0.8 ...

  • Page 4

    25-pin d-sub male connector pinout pin name rs232 rs485 full-duplex rs485 half-duplex 2 interface tx tx+ rtx+ 3 (sw selectable) rx rx+ 2 - 4 rts tx– rtx– 5 cts rx– 2 - step 2 – mounting and positioning the system 1. To mount the barcode scanner, use the mounting bracket to obtain the most suitable p...

  • Page 5

    Step 3 – smart-teach configuration smart-teach is the intuitive human machine interface designed to improve ease of installation and maintenance. Status and diagnostic information are presented using the five colored leds, and the single push button gives immediate access to the following functions:...

  • Page 6

    2. Release the button to enter the auto learn function. The reader begins to automatically detect and recognize barcodes (by type and length) that are presented to it 3 . The laser turns on and the learn led blinks to indicate the ongoing process. Setup learn test ready good trigger com status green...

  • Page 7

    Step 4 – installing geniusplus configuration program geniusplus is a scanner configuration tool that provides several important advantages: • wizard approach for new users • multi-language version • defined configuration directly stored in the reader • communication protocol independent from the phy...

  • Page 8

    A select a barcode and drag it into one of the slots at the bottom. Click next to configure the selected barcode(s) on the following screen(s). B select operating mode and click next. On line operating mode requires the reader to be connected to an external trigger/presence sensor using i1a and i1b ...

  • Page 9

    D select hardware interface type. Click next. E specify output data format. Click next. 2 after defining the parameter values, the following window appears allowing you to complete the reader configuration as follows: • save the configuration to disk • switch to advanced mode • send the configuratio...

  • Page 10

    3 after sending the configuration to the scanner, click next. You have completed the configuration process. Click finish. 4 after clicking finish, the system information window displays. Step 5 – test mode use a code suitable to your application to test the system. 1. To enter test mode, hold down t...

  • Page 11

    3. To exit test mode, press the smart-teach push button once. Note: by default, the barcode scanner automatically exits test mode after two minutes. Advanced scanner configuration the advanced selection is available when starting the geniusplus application and is designed for expert users to complet...

  • Page 12

    Reading diagrams (tcnm-ad models) tcnm-ad-1200 (standard resolution) tcnm-ad-2200 (high resolution) tcnm-ad-1204 (standard resolution) tcnm-ad-2204 (high resolution) note: (0,0) is the center of the laser beam output window. Tcnm-ad barcode scanner 12 www.Bannerengineering.Com - tel: 763-544-3164 p/...

  • Page 13

    Conditions optic version = linear code = interleaved 2/5 or code 39 pcs = 0.90 pitch angle = 0° skew angle = 15° tilt angle = 0° reading conditions 4 = standard scan speed 4 = 500 scans/sec reading performance (tcnm-ad models) version max code resolution (mm (mils)) speed (scans/sec) 12x0 0.20 (8) 5...

  • Page 14

    Specifications sensor input power supply voltage: 10–30v dc power consumption: maximum 0.5 to 0.17 a; 5 w serial interfaces main serial interface: sw programmable: rs232; rs485 fd and hd baud rate: 1200 to 115200 auxiliary: rs232 baud rate: 1200 to 115200 id-net ™ : rs485 half-duplex baud rate: up t...

  • Page 15

    Mechanical installation the barcode scanner can be installed to operate in different positions. The four screw holes (m4 x 5) on the body of the reader are for mechanical fixture. The diagrams below give the overall dimensions of the scanner and mounting bracket and may be used for installation. 23....

  • Page 16

    Safety and compliance notices warning: not to be used for personnel protection never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personne...

  • Page 17

    Ce compliance warning: this is a class a product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Handling the tcnm-ad is designed to be used in an industrial environment and is built to withstand vibration and sho...