Pb (lead-sulphuric acid) battery program
Display
Pb[0] CHARGE
4.0A 12.0V(6P)
Display
Pb-6 4.0A 12.59V
CHG 022:43 00682
This is programmed for charging and discharging Pb (lead-acid) battery of nominal
voltage from 2 to 36V. Pb batteries are totally different from NiCd or NiMH batteries.
They can only deliver relatively lower current compare to their capacity, and similar
restrictions definitely apply to charge. So the optimal charge current will be 1/10 of the
capacity. Pb batteries must not be charged rapidly. Always follow the instruction which
is supplied by the manufacturer of battery.
Set up the charge current on the left and the nominal
voltage of the battery on the right. The charge current
ranges from 0.1 to 12.0A and the voltage should be
matched with the battery being charged.
ENTER the charge process by pressing
‘ENTER/START’ button for more than 3 seconds.
The screen displays the state of charging process. To
stop charging forcibly, press ‘TYPE/STOP’ button
once.
Charging Pb battery
+
-
+
-
ENTER
START
TYPE
STOP
DEC
INC
DEC
INC
battery
voltage
charge
current
charged
capacity
elapsed
time
battery
type
Display
Pb DISCHARGE
4.0A 12.0V(6P)
Display
Pb-6 4.0A 12.59V
DSC 022:43 00682
Discharging Pb battery
+
-
+
-
ENTER
START
TYPE
STOP
DEC
INC
DEC
INC
battery
voltage
discharge
current
discharged
capacity
elapsed
time
battery
type
Set discharge current on the left and final voltage on
the right. The discharge current ranges from 0.1 to
7.0A.
The screen displays the current state of discharge.
To stop discharging press ‘TYPE/STOP’ button once.
The audible sound indicates you at the end of
process.
- 16 -
+
-
+
-
+
-
+
-
+
-
+
-
-
+
-
+
-
-
+
-
+
-
+
-
+
-
!
!
!