    Installation instructions & manual for annual maintenance evo 80-65 wood-burning built-in appliance barbas wishes you many cosy evenings with your new appliance this document is an essential part of your fi re. Read it carefully before installation and maintenance of the gas fi re and keep it in a s...

  • Page 3: Table of Contents

    3 evo 80-65 installation instructions table of contents page 1 introduction ................................................................................................. 7 2 placing ........................................................................................................ 9 3 insta...

  • Page 4

    4 evo 80-65 installation instructions.

  • Page 5

    5 evo 80-65 installation instructions.

  • Page 6

    6 evo 80-65 installation instructions.

  • Page 7

    7 evo 80-65 installation instructions 1 introduction 1.1 general the appliance must be positioned and connected by a barbas dealer/specialist in accordance with these installation instructions, nationally and locally applicable regulations. This manual contains directions for both positioning and fo...

  • Page 8

    8 evo 80-65 installation instructions • follow the instructions issued by your local fi re brigade. The appliance can be taken in operation if national and local regulations are satisfi ed. The required constructive adaptations should be satisfi ed as well. • it is essential that the appliance, the ...

  • Page 9

    9 evo 80-65 installation instructions 2 placing 2.1 appliance description figure 1: overview appliance figure 2: overview appliance including optional stone plateau 1 ceramic heat-proof glass 2 outlet opening (2x grate) (chimney breast) natural convection air 3 outlet opening (2x grill convection se...

  • Page 10

    10 evo 80-65 installation instructions 2.2 preparation for positioning 2.2.1 general function control check all functions of the appliance before fi tting. • check the opening and closing operation of the door by means of the remote control (for the operation of the remote control see chapter 3 of t...

  • Page 11

    11 evo 80-65 installation instructions • check whether the retardant plates (brake plates) are located correctly. • check the operation of the slider for the regulation of the combustion air intake (middle below the window). • check whether the ashtray is completely empty. • report any defects immed...

  • Page 12

    12 evo 80-65 installation instructions 2.2.2 connection possibilities: important: the appliance is supplied with a pre-fi tted air box or fan box (if applicable). It is not possible to alter this after delivery. I installing in an existing or new fi replace. A build-in. Without air- or fan box b bui...

  • Page 13

    13 evo 80-65 installation instructions c build-in with air box. Without convection set. Convection air through the chimney breast. D build-in with air box. With convection set. Convection air supply through a grate in the bottom side of the fi replace. Convection air through the chimney breast..

  • Page 14

    14 evo 80-65 installation instructions ii installing the appliance with a fan box. • directly external combustion air supply • convection fan with built-in dimmer switch • convection air supply through a grate/opening from the living room a build-in with fan box. With convection set. B build-in with...

  • Page 15

    15 evo 80-65 installation instructions 2.2.3 combustion air intake the local chimney sweep/authorities must be consulted prior to fi tting regarding the suitability and combustion air supply. Din 18160 (house chimneys) must be observed. Din 18895 parts 1 and 3 also apply. The air, which is piped in ...

  • Page 16

    16 evo 80-65 installation instructions • combustion air from the living-room: when using the appliance, please ensure there is a suffi cient supply of fresh air: use a grate with a minimum net opening in the outer wall of 150 cm 2 . When necessary, the combustion air inlet Ø125 mm at the underside o...

  • Page 17

    17 evo 80-65 installation instructions 2.2.4 combustion air supply / chimney every appliance needs its own chimney. Multiple connections to one main chimney is not permitted. Ensure that any existing chimney is completely air-tight and in good condition. It must be suitable to accommodate the applia...

  • Page 18

    18 evo 80-65 installation instructions 2.2.5 convection air supply and- outlet convection air (heating air) is exclusively for the transfer of heat from the appliance to the living space. This air comes from the room and stays in the room. • use convection set: the function of the convection set (op...

  • Page 19

    19 evo 80-65 installation instructions knock out two “break-away” discs of the fan box with a hammer. 1x circular disc left or right - back. This will be the convection air inlet. Place the collar adapter (125 mm) on the convection air intake opening. 1x circular disc left or right - front. This wil...

  • Page 20

    20 evo 80-65 installation instructions built-in box for dimmer. Refer to the electrical wiring diagram supplied separately with the fan box, connect the dimmer to the fan. For maintenance, the convection fan can be reached after removal of the complete fl oor of the combustion. Knock out one round d...

  • Page 21

    21 evo 80-65 installation instructions place the included collar adapter in the air intake opening. Construct a direct combustion air supply from the outside by means of a metal (fl exible) tube (125 mm) and a grate on the outer wall. Only replace the door in the appliance after fi tting the complet...

  • Page 22

    22 evo 80-65 installation instructions * table1: data on heat-insulating materials (permitted heat-insulating materials are those in grey). Insulation material delevired in ... Heat conductivity max user temperature density co- de co- de co- de co- de co- de sort form can be delivered as ºc kg/m³ 99...

  • Page 23

    23 evo 80-65 installation instructions 3 installation 3.1 general when fi tting one of these appliances local and/or national regulations relating to fi re safety must be followed. In case of doubt, consult the fi re safety department of the local fi re brigade, particularly if the fi re is to be fi...

  • Page 24

    24 evo 80-65 installation instructions legend page 26 a example build-in in a ventilated chimney. Appliance is fi tted with a convection set. B example build-in in a ventilated chimney. Convection air through the chimney breast..

  • Page 25

    25 evo 80-65 installation instructions c example build-in in a ventilated chimney. Appliance is fi tted with an air box and a convection set. For a direct combustion air supply from outside. D example build-in in a ventilated chimney. For a direct combustion air supply from outside and fi tted with ...

  • Page 26

    26 evo 80-65 installation instructions legend: 1 inlet opening combustion air / convection air / chimney-ventilation air (grate, bottom of chimney) 2 inlet opening combustion air (bottom of appliance Ø125 mm) / (air-box, Ø125 mm) / (fan box, Ø125 mm) 4 inlet opening convection air (fan box, Ø125 mm)...

  • Page 27

    27 evo 80-65 installation instructions • if the appliance is to be placed against a bearing wall or against a wall containing fl ammable material, an air gap of at least 20 mm should fi rst be created. Before it a false wall, 100 mm thick, must be built of masonry or aerated concrete. • if the appli...

  • Page 28

    28 evo 80-65 installation instructions - appliance with substructure fan box (convection fan): use the Ø125 mm (external) combustion air supply connection at the left of right front side of the fan box. Fit a rigid or fl exible pipe measuring Ø125 mm between this air supply connection and the “outsi...

  • Page 29

    29 evo 80-65 installation instructions 3.2.5 fitting the natural stone plateau to install the natural stone plateau use the two 6*16 fl ange bolts supplied, combination or box spanner 10, and an allen key. • ventilate the chimney, by placing ventilation openings at the top and bottom of the chimney ...

  • Page 30

    30 evo 80-65 installation instructions put the lift door in the top position and place the plateau in its designated position in the appliance. Fix the plateau at the rear with the 2 fl ange bolts. The plateau can be levelled using the 2 allen set screws on the underside of the plateau. To adjust th...

  • Page 31

    31 evo 80-65 installation instructions it is essential that the appliance, the chimney and the combustion air supply are cleaned and inspected annually, by a barbas-dealer/expert. The safe operation of the appliance will thus remain guaranteed. 4 annual maintenance start with maintence 24 hours afte...

  • Page 32

    32 evo 80-65 installation instructions … outside appliance: • clean the outside of the appliance with a dry lint free cloth. • wait for the appliance to cool down suffi ciently before cleaning. Never use scouring powder, aggressive cleaners or fi re polish on the appliance. • any lacquer damage can ...

  • Page 33

    33 evo 80-65 installation instructions 5 dimensions 5.1 evo 80-65 • with 80 mm frame.

  • Page 34

    34 evo 80-65 installation instructions 5.2 evo 80-65 • with 80 mm frame • with natural stone plateau.

  • Page 35

    35 evo 80-65 installation instructions 6 replacement parts item no article number description 1 334526 retardant plate top, right 2 334527 retardant plate top, left 3 334532 retardant plate under 4 333984 side panel, left 5 333979 rear panel 6 333985 side panel, right 7 334515 grate 8 334483 door 9 ...

  • Page 36

    36 evo 80-65 installation instructions 7 technical data evo 80-65 combustion: measured in compliance with en 13229 : 2001 and en 13229 - a2 : 2004 fuel wood nominal output 14 kw effi ciency 82% emissions (dry, at 13% o 2 , 273k, 1013 hpa): carbon monoxide (co) 0.1 %; 1237 mg/m 3 (stp, at 13% o 2 ) d...

  • Page 37

    37 evo 80-65 installation instructions combustion air supply: at least 150 cm 2 opening in the room where the fi re is located or a outside air supply opening of Ø125 mm in wall/fl oor. Opties: • fan box with 230 vac / 95 w fan (perma air ® ) for transport of heating air. Rev control by built-in fan...

  • Page 38

    38 evo 80-65 installation instructions 8 warranty terms interfocos warranty terms interfocos b.V. Guarantees the quality of the supplied barbas appliance and the quality of the materials used. All barbas appliances are developed and manufactured according to the highest possible quality standards. I...

  • Page 39

    39 evo 80-65 installation instructions c. It has not be used or maintained according to the instructions for use; d. It has been changed, neglected or roughly treated; e. It has been damaged as a result of external causes (outside the appliance itself), for example, lightning strike, water damage or...

  • Page 40: Your Barbas Dealer

    01 - 151013 - 334801 your barbas dealer.