Barbas UNICA 100 Instructions For Use Manual

Summary of UNICA 100

  • Page 1

    Instructions for use installation instructions country natural gas propane great-britain / ireland unica 50 ng unica 50 pg unica 52 ng unica 52 pg unica 65 ng unica 65 pg unica 70 ng unica 70 pg unica 100 ng unica 100 pg unica 50 unica 52 unica 65 unica 70 unica 100

  • Page 3: Contents

    3 unica 70 unica 100 unica 65 unica 50 unica 52 contents 1. Instructions for use...................................................... 2. Installation instructions............................................... 3. Maintenance...................................................................... 4. F...

  • Page 4

    4 unica 70 unica 100 unica 65 unica 52 unica 50

  • Page 5

    5 unica 70 unica 100 unica 65 unica 50 unica 52 1 instructions for use 1.1 introduction congratulations on your purchase of this modern barbas gas fi re. This quality product will provide you with many years of enjoyment due to the fl ame effect and warmth that it provides. Please read the instructi...

  • Page 6

    6 unica 70 unica 100 unica 65 unica 52 unica 50 the fi lling of the main burner with embers, vermiculite granules and wood logs may not under any circumstances be changed or added to. Do not place easily-fl ammable materials, such as nylon clothing or fl ammable liquids, in the vicinity of the gas f...

  • Page 7

    7 unica 70 unica 100 unica 65 unica 50 unica 52 figure 1: hand control 1.4 igniting the fire l open the gas supply valve in the gas pipe to the appliance. L lock the slider into “l” position. L turn the thermostat knob to the ignition position “«” and then push the knob in. L while keeping the therm...

  • Page 8

    8 unica 70 unica 100 unica 65 unica 52 unica 50 1.5 turning off the fire l turn the thermostat knob to the ignition position “«”. L lock the slider to the “l” position. The burner will now be fully extinguished. If the thermostat knob is turned back to the “1” position, then the burner will continue...

  • Page 9

    9 unica 70 unica 100 unica 65 unica 50 unica 52 b a figure 2: operating switch 1.7.2 igniting the fi re l open the gas valve in the gas supply pipe to the appliance l turn the control knob b to the position where the “big fl ame”-symbol is located. L turn the control knob a a little to the left unti...

  • Page 10

    10 unica 70 unica 100 unica 65 unica 52 unica 50 1.7.3 flame height the fl ame height of the main burner can now be adjusted by means of control knob b. Manually in approximately 20 steps or by means of the cordless remote control (continuous). Turning knob b to the left in the direction of the “big...

  • Page 11

    11 unica 70 unica 100 unica 65 unica 50 unica 52 changing batteries signal temperature display °c - °f heating period p1 and p2 time display button high man setting timer setting time button low man setting timer setting time sendsymbol auto timer man display button auto button timer figure 4: hand-...

  • Page 12

    12 unica 70 unica 100 unica 65 unica 52 unica 50 1.7.5 extinguishing the fi re turn knob b, possibly with the remote control, fully to the right to the l symbol and/or turn the control knob a to the right until the stop (“small fl ame” symbol = pilot light position). The main burner will still burn ...

  • Page 13

    13 unica 70 unica 100 unica 65 unica 50 unica 52 1.7.10 man mode for manual fl ame height adjustment l press to turn on the fi re (main burner) or to increase fl ame height. L press to decrease fl ame height or to turn down the main burner. The pilot stays on. L to incrementally increase or decrease...

  • Page 14

    14 unica 70 unica 100 unica 65 unica 52 unica 50 important: if the pilot light goes out for any reason, wait for 5 minutes before attempting to re-light it. 1.7.15 replacing the batteries the batteries of the hand-held transmitter and reciever have a lifespan of approximately one year. If batt appea...

  • Page 15

    15 unica 70 unica 100 unica 65 unica 50 unica 52 1.8 using the appliance for the first time the gas fi re is coated with a lacquer layer resistant to high temperature. During the fi rst hours of operation, the burning in of the lacquer may result in an unpleasant smell. This is harmless, however. Op...

  • Page 16

    16 unica 70 unica 100 unica 65 unica 52 unica 50 2 installation instructions 2.1 general the gas fi re must be positioned and connected as a “open” appliance by a corgi registered installation engineer in accordance with the following installation instructions, nationally and locally applicable regu...

  • Page 17

    17 unica 70 unica 100 unica 65 unica 50 unica 52 2.3 preparations before installation before installing the appliance, fi rst observe the following instructions. 2.3.1 the most important facilities according to the regulations: 1 naturally ventilated house (see figure 6). L the room in which the app...

  • Page 18

    18 unica 70 unica 100 unica 65 unica 52 unica 50 2 mechanically ventilated house (see figure 7) l the room in which the appliance is to be fi tted must have a non- closable combustion air supply opening. The minimum dimensions are detailed in “technical details/regulations” at the rear of this manua...

  • Page 19

    19 unica 70 unica 100 unica 65 unica 50 unica 52 2.4 general services 1. Unpacking the appliance the appliance is fi tted with two “carrying handles” at the top. If required, they may be removed during installation. 2. Frame the appliance is fi tted with a 20 mm wide frame as standard. A detachable ...

  • Page 20

    20 unica 70 unica 100 unica 65 unica 52 unica 50 2.5 positioning the appliance important: l never use combustible materials during the installation. L insulate the gas fi re using white loose insulation wool (heat resistant up to 1000°c). Not at the bottom !! L flammable materials, such as curtains,...

  • Page 21

    21 unica 70 unica 100 unica 65 unica 50 unica 52 position the thermostat sensor at the left-or right hand side underneath the frame, or at the height of the plinth. See paragraphe 2.5.3 for fi tting the log set. Check that all connections are completely gas tight using soapy water or a leak tester. ...

  • Page 22

    22 unica 70 unica 100 unica 65 unica 52 unica 50 3. Dismantling the frame: when necessary, the 50 mm frame can be removed (unica 50: 32 mm). Unica 50 : loosen the screws underneath at the left-and right hand side, unica 70 at the inside of the frame, and remove the frame by pulling it unica 100 forw...

  • Page 23

    23 unica 70 unica 100 unica 65 unica 50 unica 52 figure 8: unica 50 / unica 70 / unica 100 unica 52 : dismantle the entire inner shell by slightly loosening the 4 unica 65 nuts at the front. Next, turn the adjustment bolt downwards at the left-and right hand side bottom which slightly lowers the inn...

  • Page 24

    24 unica 70 unica 100 unica 65 unica 52 unica 50 10. The fl ue spigot can be removed by loosening the self-tapping screws from the inside of the outer casing. The appliance is now fully dismantled. Figure 9: unica 52 / unica 65 front flue spigot outer casing inner shell control unit door 50 mm frame...

  • Page 25

    25 unica 70 unica 100 unica 65 unica 50 unica 52 installing the gas fi re insert should be carried out in the following order: 1. Fitting the outer casing place the outer casing into the fi replace opening. Using the supplied frame, position the fi replace casing horizontally and vertically level to...

  • Page 26

    26 unica 70 unica 100 unica 65 unica 52 unica 50 2. Fitting the inner shell before assembly, check that the sealing cords of the fl ue spigot and glass are still intact. Unica 50 : hook the complete inner shell onto the hinge points at the top unica 70 left and right hand corner of the casing. Tilt ...

  • Page 27

    27 unica 70 unica 100 unica 65 unica 50 unica 52 the mains electricity can now be restored to the wall socket. (only applicable if the appliance is provided with a convection fan.) check that all connections are completely gas tight using soapy water or a leak tester. As a check, allow the fi re to ...

  • Page 28

    28 unica 70 unica 100 unica 65 unica 52 unica 50 figure 10: log set unica 50 natural gas-appliance position of embers, vermiculite granules and logs on burner unica 50: positioning the ceramic log set: natural gas-appliance: unica 50 n... 1. Carefully remove the embers (1x 125 gram) from the packagi...

  • Page 29

    29 unica 70 unica 100 unica 65 unica 50 unica 52 propane-appliance: unica 50 p... 1. Carefully remove the embers (1x 125 gram) from the packaging and place them evenly on and around the burner (not on the holes!). Please make sure that all burner orifi ces (small holes) are kept unblocked ! Note ! S...

  • Page 30

    30 unica 70 unica 100 unica 65 unica 52 unica 50 unica 52: positioning the ceramic log set: natural gas-appliance: unica 52 n... Evenly distribute the vermiculite granules over the burner. Place the rear log set; no †, in the holder behind the burner. After that, position the 5 remaining logs; no ,...

  • Page 31

    31 unica 70 unica 100 unica 65 unica 50 unica 52 unica 65 / unica 70: positioning the ceramic log set: natural gas-appliance: unica 65 n... / unica 70 n... Evenly distribute the vermiculite granules over the burner. Place the rear log set; no †, in the holder behind the burner. After that, position ...

  • Page 32

    32 unica 70 unica 100 unica 65 unica 52 unica 50 unica 100: positioning the ceramic log set: natural gas-appliance: unica 100 n... 1. Carefully remove the embers (2 x125 gram) from the packaging and place them evenly on the burner. Note ! Small embers and their residue should not be scattered on the...

  • Page 33

    33 unica 70 unica 100 unica 65 unica 50 unica 52 figure 15: unica 100 natural gas-appliance position of embers and logs on burner propane-appliance: unica 100 p... 1. Carefully remove the embers (1 x125 gram) from the packaging and place them evenly on and around the burner. Please make sure that al...

  • Page 34

    34 unica 70 unica 100 unica 65 unica 52 unica 50 figure 16: unica 100 propane-appliance position of embers on burner figure 17: unica 100 propane-appliance position of embers and logs on burner positioning the rear logs the carbon side to the top embers must not be placed next to the pilot light bur...

  • Page 35

    35 unica 70 unica 100 unica 65 unica 50 unica 52 6. Fitting the front, door and glass (wear protective gloves !!!) unica 50 : first position the glass into the glass support plate at the bottom or unica 70 the combustion chamber. Push the glass against the cord and unica 100 clip it on with three gl...

  • Page 36

    36 unica 70 unica 100 unica 65 unica 52 unica 50 3 maintenance 3.1 annual maintenance it is essential that the appliance, the chimney and the burner air intake are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed. ...

  • Page 37

    37 unica 70 unica 100 unica 65 unica 50 unica 52 4 faults possible reasons for the gas fi re going out are: l operation of the thermal one-way protection safety system due to fl ue gas escape. L malfunction of the thermal one-way protection safety system. Check by means of testing. L insuffi cient g...

  • Page 38

    38 unica 70 unica 100 unica 65 unica 52 unica 50 5 electrical diagram blue brown yellow/green brown brown brown blue yellow/green fanspeed controller convection-fan 230 vac / 50 hz convection-fan 230 vac / 50 hz thermostat “clickson” set at ± 40° c earthed plug (with earth sleeve) 230 vac cabel clam...

  • Page 39

    39 unica 70 unica 100 unica 65 unica 50 unica 52 6 dimensions 6.1 unica 50 gas connection.

  • Page 40

    40 unica 70 unica 100 unica 65 unica 52 unica 50 6.2 unica 52 gas connection 525 (fi xed frame) (fi xed frame).

  • Page 41

    41 unica 70 unica 100 unica 65 unica 50 unica 52 6.3 unica 65 gas connection (fi xed frame) (fi xed frame).

  • Page 42

    42 unica 70 unica 100 unica 65 unica 52 unica 50 6.4 unica 70 (fi xed frame) plateau (fi xed frame) gas connection.

  • Page 43

    43 unica 70 unica 100 unica 65 unica 50 unica 52 6.5 unica 100 (fi xed frame) (fi xed frame) gas connection.

  • Page 44

    44 unica 70 unica 100 unica 65 unica 52 unica 50 7 technical details / regulations 7.1 technical details; ng; natural gas - great britain / ireland pg; propane - great britain / ireland national installation regulations: gas safety installation and use regulations 1984 plus all relevant safety and b...

  • Page 45

    45 unica 70 unica 100 unica 65 unica 50 unica 52 model : unica 52 ng : unica 52 pg country : gb; great britain / ie; ireland : gb; great britain / ie; ireland product identifi cation no : 0063 au 3899 : 0063 au 3899 type of appliance under ce-norm : b 11bs : b 11bs category of appliance : i 2h , nat...

  • Page 46

    46 unica 70 unica 100 unica 65 unica 52 unica 50 model :unica 65 ng :unica 65 pg unica 70 ng unica 70 pg country : gb; great britain / ie; ireland : gb; great britain / ie; ireland product identifi cation no : 0063 au 3899 : 0063 au 3899 type of appliance under ce-norm : b 11bs : b 11bs category of ...

  • Page 47

    47 unica 70 unica 100 unica 65 unica 50 unica 52 model : unica 100 ng : unica 100 pg country : gb; great britain / ie; ireland : gb; great britain / ie; ireland product identifi cation no : 0063 au 3899 : 0063 au 3899 type of appliance under ce-norm : b 11bs : b 11bs category of appliance : i 2h , n...

  • Page 48

    48 unica 70 unica 100 unica 65 unica 52 unica 50 8 replacement parts list when requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a barbas dealer. 8.1 unica 50 no part no description hand remote control...

  • Page 49

    49 unica 70 unica 100 unica 65 unica 50 unica 52 no part no description hand remote control control 27 301617 black fi bre glass cord Ø10 mm; l = 2000 mm 28 301595 fibre glass tape 20 x 6 mm; l = 360 mm 29 301592 fibre glass tape 15 x 3 mm; l = 1300 mm 30 301607 black fi bre glass cord Ø6 mm; l = 19...

  • Page 50

    50 unica 70 unica 100 unica 65 unica 52 unica 50 8.2 unica 52 no part no description hand remote control control 1 302056 gas regulator block, eurosit plus 0.630.704 2 301965 piezo push-button 3 302037 minimal heatinput adj. Screw 1.6 mm; natural gas 4 302041 minimal heatinput adj. Screw 1.0 mm; pro...

  • Page 51

    51 unica 70 unica 100 unica 65 unica 50 unica 52 no part no description hand remote control control 33 301669 tube ceramic glue 34 301845 log set unica 52, natural gas and propane 35 301839 vermiculite granules (± 5 gram) x x x x x x.

  • Page 52

    52 unica 70 unica 100 unica 65 unica 52 unica 50 8.3 unica 65 / unica 70 no part no description hand remote control control 1 302056 gas regulator block, eurosit plus 0.630.704 2 301965 piezo push-button 3 302037 minimal heatinput adj. Screw 1.6 mm; natural gas 4 301967 minimal heatinput adj. Screw ...

  • Page 53

    53 unica 70 unica 100 unica 65 unica 50 unica 52 no part no description hand remote control control 32 301607 black fi bre glass cord Ø6 mm; l = 2220 mm (unica 65) 33 301614 black fi bre glass tape 10 x 2 mm; l = 375 mm 34 301669 tube ceramic glue 35 301844 log set unica 65/unica 70, natural gas and...

  • Page 54

    54 unica 70 unica 100 unica 65 unica 52 unica 50 8.4 unica 100 no part no description hand remote control control 1 302056 gas regulator block, eurosit plus 0.630.704 2 301965 piezo push-button 3 302037 minimal heatinput adj. Screw 1.6 mm; natural gas 4 301967 minimal heatinput adj. Screw 1.3 mm; pr...

  • Page 55

    55 unica 70 unica 100 unica 65 unica 50 unica 52.

  • Page 56

    04 - 010507 - 303430 interfocos b.V. Hallenstraat 17 5531 ab bladel nederland e-mail: info@barbas.Nl internet: www.Barbas.Com.