BURNER ORIFICE
LOG
NATURAL
PROPANE/LP
SIZE
IN.
NUM.
IN.
NUM.
18SR/DR
.120
31
.073
49
24SR/DR/BFLR18
.129
30
.086
44
30DR/BFLR24
.1405
28
.089
43
FLUE OPENING SPECIFICATIONS
Note:
This vented appliance must be installed only in a solid-fuel
burning fireplace with a working flue and constructed of noncom-
bustible material.
The charts in Figure 2 indicate technical information regarding the
installation of your gas log set. Please make sure that all of the
specifications shown are applicable before installation is attempted.
The fireplace must include a working flue and venting system with
the minimum openings shown in the Figure 2.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, you must
install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 15).
Call dealer where you bought log set.
If the fireplace does not have a gas supply shut-off valve, one must
be installed.
MODEL
DESCRIPTION
BVSR18 18" Single Burner
50,000
40,000
8" dia.
BVSR24 24" Single Burner
60,000
50,000
8" dia.
BVDR18 18" Dual Burner
55,000
45,000
8" dia.
BVDR24 24" Dual Burner
65,000
55,000
8" dia.
BVDR30 30" Dual Burner
70,000
60,000
8" dia.
BFLR18
18" Triple Burner
65,000
55,000
8" dia.
BFLR24
24" Triple Burner
70,000
60,000
8" dia.
Btu Input
Natural
Gas
Btu Input
Propane/LP
Gas
Minimum
Vent
Opening
*Add 6" if safety valve/pilot is used
**At depth indicated
FUEL INLET PRESSURE
SPECIFICATIONS ("W.C.)
Min.
Max.
NG
5.5
10.5
LP
11
13
Figure 2 - Technical Information Charts
INSTALLATION
WARNING: Before installing in a solid fuel burning
fireplace, the chimney flue and firebox must be cleaned
of soot, creosote, ashes and loose paint by a qualified
chimney cleaner. Creosote will ignite if highly heated.
A dirty chimney flue may create and distribute soot
within the house. Inspect chimney flue for damage.
NOTICE: Installation, service, and repair of this appli-
ance must be performed by a qualified installer,
service agency, company or gas supplier experi-
enced with this type of gas appliance. Only factory
authorized components listed in these instructions
may be used in accordance with the manufacturer’s
instructions and all codes and requirements of the
authority having jurisdiction. Any modifications to
this kit, or use of unauthorized components or acces-
sory items will void the manufacturer’s warranty, and
may result in a hazardous condition.
CAUTION: Do not remove the data plates at-
tached to the burner pan. The data plates contain
important warranty information.
INSTALLATION
Flue Opening Specifications
Check Gas Type
MINIMUM FIREBOX SIZES
FRONT
BACK
MODEL
WIDTH*
WIDTH**
DEPTH
HEIGHT
18DR/SR
28"
16"
14"
18"
24DR/SR
29
3
/
4
"
17"
15
1
/
2
"
18"
30DR
36"
27"
18"
18"
BFLR18
28"
16"
15
1
/
2
"
18"
BFLR24
33"
22"
15
1
/
2
"
18"